DSC pc1565 Installation Manual page 44

Hide thumbs Also See for pc1565:
Table of Contents

Advertisement

6HFWLRQ
5HSRUWLQJ &RGH
[349-350]
AC Line Trouble/Rest.
[349-350]
Main Bell Trouble/Rest.
[349-350]
Fire Trouble/Rest.
[349-350]
Auxiliary
Power
Rest.
[349]
TLM Failure
[350]
TLM Restore
[349-350]
Gen
System
Trouble/Rest.
[351]
Line 1 or 2 FTC Restoral
[351]
Event Buffer is 75% Full
[351]
DLS Lead In
[351]
DLS Lead Out
[351]
Zone Fault/Rest.
[352]
Periodic Test
[352]
System Test
[352]
LINKS Test
[353]
Wireless Device Low Battery
Trouble/Rest.
* A/R = alarms/restorals;T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
Table2: Contact ID Zone Alarm/Restoral Event
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using
the standard (non-automatic) Contact ID reporting format.
0HGLFDO $ODUPV
(1)AA Medical
(1)A1 Pendant Transmitter
(1)A2 Fail to Report In
)LUH $ODUPV
(1)1A Fire Alarm
(1)11 Smoke
(1)12 Combustion
(1)13 Water Flow
(1)14 Heat
(1)15 Pull Station
(1)16 Duct
(1)17 Flame
(1)18 Near Alarm
3DQLF $ODUPV
(1)2A Panic
(1)21 Duress
(1)22 Silent
(1)23 Audible
%XUJODU $ODUPV
(1)3A Burglary
(1)31 Perimeter
(1)32 Interior
(1)33 24 Hour

&RGH 6HQW :KHQ
AC power to control panel is disconnected or inter-
rupted/AC power restored (Both codes follow AC Fail-
ure Comm. Delay.)
open circuit detected across bell terminals/bell circuit
closed
a trouble occurs/restores on a fire zone
Trouble/
aux voltage supply trouble/restoral
telephone line monitoring trouble (sent via LINKS. Do
not program if LINKS not used)
Telephone line trouble restore
Supervisory
control panel loses/restores communications with mod-
ule(s) connected to the Keybus
control panel has restored communications to central
station on line 1 or 2 (after FTC)
event buffer is almost full since last upload
downloading session start
downloading session complete
one or more zones have fault/fault restored
periodic system test transmission
[*][6] bell/communications test
LINKS test transmission
wireless zones, panic pendants, handheld keypads,
wireless keys have low battery/all low batteries restored
(1)34 Entry / Exit
(1)35 Day / Night
(1)36 Outdoor
(1)37 Tamper
(1)38 Near Alarm
*HQHUDO $ODUPV
(1)4A General Alarm
(1)43 Exp. module failure
(1)44 Sensor tamper
(1)45 Module Tamper
(1)4A Cross Zone Police Code
 +RXU 1RQ%XUJODU\
(1)5A 24 Hour non-Burg
(1)51 Gas detected
(1)52 Refrigeration
(1)53 Loss of Heat
(1)54 Water Leakage
(1)55 Foil Break
(1)56 Day Trouble
(1)57 Low bottled Gas level
(1)58 High Temp
(1)59 Low Temp
(1)61 Loss of Air Flow
'LDOHU
'LUHFWLRQ
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
T
T
T
MA/R
** UU = user number (user01-42); ZZ = zone number (01-08)
Table 3: SIA Format Automatic Zone
Alarm/Restoral Codes
=RQH 'HILQLWLRQ
Delay, Instant, Interior, Delay
Stay/Away, Interior Stay/Away,
24Hr Burg.
Standard 24Hr Fire, Delayed
24Hr Fire
24Hr Supervisory
24Hr Supervisory Buzzer
24Hr Sprinkler
24Hr Gas
24Hr Heat
24Hr Medical
24Hr Emergency (non-medical)
24Hr Waterflow
24Hr Freeze
24Hr Holdup
24Hr Panic
Latching 24Hr, 24-Hr Bell/Buzzer
&RQWDFW
6,$ $XWR 5HS
,' &RGHV
&RGHV
(3) A1
AT-00/AR-00
(3) 21
UT-99/UJ-99
(3) 73
FT-00/FJ-00
(3) AA
YP-00/YQ-00
(3) 51
LT-00
(3) 51
LR-00
(3) 33
ET-00/ER-00
(3) 54
YK-00
(6) 23
JL-00
(4) 11
RB-00
(4) 12
RS-00
(3) 72
UT-00/UJ-00
(6) A2
RP-00
(6) A1
RX-00
(6) A3
TX-00
(3) 84
XT-00/XR-00
6,$ $XWR 5HS
&RGHV
Zone Alm/Rest.
BA-ZZ/BH-ZZ
FA-ZZ/FH-ZZ
US-ZZ/UR-ZZ
UA-ZZ/UH-ZZ
SA-ZZ/SH-ZZ
GA-ZZ/GH-ZZ
KA-ZZ/KH-ZZ
MA-ZZ/MH-ZZ
QA-ZZ/QH-ZZ
WA-ZZ/WH-ZZ
ZA-ZZ/ZH-ZZ
HA-ZZ/HH-ZZ
PA-ZZ/PH-ZZ
BA-ZZ/BH-ZZ
* ZZ = zones 01-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents