5.18 Entry/Exit Delay Options
Two different (QWU\ 'HOD\V can be programmed: the first entry
delay will be enabled for Delay 1 type zones and the second
for Delay 2 type zones. Only one ([LW 'HOD\ can be pro-
grammed.
127(:KHQ WKH SDQHO LV DUPHG WKH HQWU\ GHOD\ ZLOO IROORZ WKH
HQWU\ GHOD\ WLPH SURJUDPPHG IRU WKH GHOD\ ]RQH ZKLFK LV YLR
ODWHG ILUVW
Upon arming, the panel will begin the exit delay. If the $XGLEOH
([LW 'HOD\ ZLWK 8UJHQF\ option is enabled, the keypad will
beep at one second intervals until the exit delay expires. The
keypad will beep rapidly for the last 10 seconds of exit delay
to warn the user that the system is about to arm. If this option
is disabled, the keypad will not beep during the exit delay.
The $XGLEOH ([LW )DXOW, as explained in section 3.1 "Arming
and Disarming" on page 7, will notify the user if they failed to
secure the premises upon arming. This option can be enabled
or disabled according to the user's needs.
For commercial applications, the %HOO 6TXDZN RQ ([LW 'HOD\
option may be enabled. The panel will squawk the alarm out-
put once every second when the exit delay is initiated and
three times per second for the last 10 seconds until the exit
delay expires.
127(7KH EHOO ZLOO QRW VTXDZN ZKHQ WKH SDQHO LV 6WD\ RU 1R
HQWU\ DUPHG
Upon entry, if a Delay type zone is violated, the panel will
begin the entry delay. The keypad will emit a steady tone. The
keypad will pulse the keypad sounder during the last 10 sec-
onds to warn the user the system is about to go into alarm. If
there was an alarm during the armed period, the keypad will
pulse for the entire entry delay to warn the user of the previous
alarm.
For commercial applications %HOO 6TXDZN RQ (QWU\ 'HOD\
may be enabled. The panel will squawk the alarm output once
every second until the entry delay expires or the system is dis-
armed.
If the %HOO 6TXDZN 'XULQJ $XWR $UP option is enabled, the
bell will squawk once every 10 seconds for one minute during
the Auto-arm pre-alert. This will notify anyone on the premises
that the system is being armed.
If the ([LW 'HOD\ 7HUPLQDWLRQ option is enabled, the panel will
monitor the Delay zones during exit delay. During the exit
delay, if a Delay type zone is violated and then secured, the
exit delay will be terminated and the panel will be armed
immediately.
Entry Delay 1 and 2 (System Times) . . . . . . . . Section [005]
Exit Delay (System Times) . . . . . . . . . . . . . . . . Section [005]
Audible Exit Delay with Urgency . . . . . . . . Section [014]: [6]
Audible Exit Fault Enabled/ Disabled. . . . . Section [013]: [6]
Bell Squawk Options . . . . . . . . . . . . . Section [014]: [2] - [4]
Exit Delay Termination . . . . . . . . . . . . . . . . Section [014]: [7]
P r o g r a m
D e s c r i p t i o n s :
5.19 Swinger Shutdown
The swinger shutdown feature is designed to prevent a "run-
away" communicator from tying up the central station. After
the panel has communicated the programmed number of
transmissions for an event, it will no longer report that event
until the swinger shutdown is reset. Different swinger shut-
down levels can be set for zone alarms, zone tampers and
maintenance signals.
By default, each swinger shutdown limit is set to [003]. The
panel will not send more than three signals for each zone until
the swinger shutdown is reset.
The Bell output will not be activated for alarms on zones that
have exceeded the limit of alarms set in the Swinger Shut-
down counter.
Swinger shutdown will be reset every day at midnight or when
the panel is armed. Once reset, the panel will again communi-
cate normally.
Swinger Shutdown . . . . . . . . . . . . . . . . . . . . . . . Section [370]
5.20 Event Buffer
The panel will store the last 128 events which occurred on the
system. The event buffer will contain the name, time and date
of each event, along with the zone number, access code num-
ber or any other information pertaining to the event.
If the (YHQW %XIIHU )ROORZV 6ZLQJHU 6KXWGRZQ option is
enabled, the Event Buffer will not store events after the
Swinger Shutdown level has been reached. This will prevent
the panel from overwriting the entire buffer if a problem exists.
The event buffer can be viewed in three different ways: from
an LCD keypad (see "[*][6] User Functions" on page 9),
printed on-site using the PC5400 printer module, or it can be
uploaded using DLS software.
Event Buffer Follows Swinger Shutdown . . .Section [013]: [7]
5.21 Keypad Lockout Options
The panel can be programmed to "lock out" keypads if a series
of incorrect access codes are entered. Once the 1XPEHU RI
,QYDOLG &RGHV %HIRUH /RFNRXW limit has been reached, the
panel will lock out all keypads for the lockout duration and log
the event to the event buffer. For the duration of the lockout, the
panel will sound an error tone when any key is pressed.
127( 7KH ,QYDOLG &RGH &RXQWHU ZLOO EH UHVHW HYHU\ KRXU
To disable the keypad lockout option, program the Number of
Invalid Codes Before Lockout as [000].
127( ,I .H\SDG /RFNRXW LV DFWLYH WKH SDQHO &$1127 EH
DUPHG  GLVDUPHG ZLWK D NH\VZLWFK
Keypad Lockout Options . . . . . . . . . . . . . . . . . . Section [012]
5.22 Keypad Blanking
If the %ODQN .H\SDG :KHQ 1RW LQ 8VH option is enabled, the
panel will turn off all lights and LCDs on the keypads when no
keys are pressed for 30 seconds. The keys, however, will
remain backlit.
The panel will turn the lights and LCDs back on if entry delay
begins or an audible alarm occurs. The lights and LCDs will
also come on if a key is pressed or, if a valid access code is
entered when the &RGH 5HTXLUHG WR 5HVWRUH %ODQNLQJ
option is enabled.