No.
Text
883
ROT Gyro 3
Sensor Banned
891
Water Current
Sensor Banned
900
No Filter Source of
Position
901
No Filter Source of
COG/SOG
902
No Filter Source of
CTW/STW
903
No Filter Source of
Heading
904
No Filter Source of
ROT
Default
Meaning
Caution
Heading data from No.3
ROT Gyro is determined
abnormal by integrity
check.
Caution
Data from water current is
determined abnormal by
integrity check.
*Currently not generated
because integrity check is
not performed for Current.
Warning
No valid position sensor is
available for filter. (Banned
or connection error)
Warning
No valid COG/SOG sensor
is available for filter.
(Banned or connection
error)
Warning
No valid CTW/STW sensor
is available for filter.
(Banned or connection
error)
Warning
No valid heading sensor is
available for filter. (Banned
or connection error)
Warning
No valid position sensor is
available for filter. (Banned
or connection error)
APPENDIX 5 ALERT LIST
Remedy
Reset the filter to confirm
that it isn't a temporal error
value. If the data is normal,
it is reusable. However, if
it's continually removed,
there is a possibility that
correct data is not received
from sensor. In this case,
contact FURUNO.
Reset the filter to confirm
that it isn't a temporal error
value. If the data is normal,
it is reusable. However, if
it's continually removed,
there is a possibility that
correct data is not received
from sensor. In this case,
contact FURUNO.
Check the connection with
all GPS.
Check the connection with
all GPS.
Check the connection with
all GPS.
Check the connection with
all GPS.
Check the connection with
all GPS.