Trigger Sensor Adjustment

Trigger Sensor Adjustment
Refer to Troubleshooting for trigger sensor adjust-
ment, and see Operation Manual 312190.

Distance Sensor Replacement

1. Remove wheel (120) from LineLazer.
2. Remove screw (273), wire clamp (115), spacer
(272) and distance sensor (66).
F
. 3
IG
16
120
130
127
142
3. Install new distance sensor (66) and spacer (272)
with wire clamp (115) and screw (273).
4. Install wheel (120) on LineLazer.
66
273
115
272
TI10237a