Installation; Trigger Sensor Adjustment - Graco LineLazer V 200MMA Operation - Repair - Parts

1:1 airless line stripers
Hide thumbs Also See for LineLazer V 200MMA:
Table of Contents

Advertisement

Gun Placement

Installation

1. Install vertical gun mount onto gun bar.
NOTE: Make sure all hoses, cables, and wires are
properly routed through brackets.

Trigger Sensor Adjustment

1. Start striper engine. Manually pull the trigger. Spray
icon should appear simultaneously with start of fluid
spray.
HP Auto Series
22
No fluid spray
2. Turn screw in handle clockwise if spray icon
appears before fluid spray starts.
No spray icon
3. Turn screw in handle counterclockwise if fluid spray
starts before spray icon appears.
4. Continue adjusting screw in handle until timing of
spray icon and fluid spray are synchronized.
ti27802a
ti27803a
3A6466A Operation, Repair, Parts

Advertisement

Table of Contents
loading

Table of Contents