KTI Networks KGS-1064-HP User Manual page 148

Web management interface
Hide thumbs Also See for KGS-1064-HP:
Table of Contents

Advertisement

Release
IP Address/Hostname
UDP Port
Timeout
Max. Datagram Size
Port Configuration
Port
Flow Sampler
Enabled
Sampling Rate
Max. Header
Counter Poller
Enabled
Interval
Save
Reset
The button is disabled if sFlow is currently unclaimed. If configured through SNMP,
the release must be confirmed (a confirmation request will appear).
The IP address or hostname of the sFlow receiver. Both IPv4 and IPv6 addresses are
supported.
The
UDP
port on which the sFlow receiver listens to sFlow datagrams. If set to 0
(zero), the default port (6343) is used.
The number of seconds remaining before sampling stops and the current sFlow owner
is released. While active, the current time left can be updated with a click on the
Refresh-button. If locally managed, the timeout can be changed on the fly without
affecting any other settings.
The maximum number of data bytes that can be sent in a single sample datagram.
This should be set to a value that avoids fragmentation of the sFlow datagrams. Valid
range is 200 to 1468 bytes with default being 1400 bytes.
The port number for which the configuration below applies.
Enables/disables flow sampling on this port.
The statistical sampling rate for packet sampling. Set to N to sample on average
1/Nth of the packets transmitted/received on the port.
Not all sampling rates are achievable. If an unsupported sampling rate is requested,
the switch will automatically adjust it to the closest achievable. This will be reported
back in this field.
The maximum number of bytes that should be copied from a sampled packet to the
sFlow datagram. Valid range is 14 to 200 bytes with default being 128 bytes.
If the maximum datagram size does not take into account the maximum header size,
samples may be dropped.
Enables/disables counter polling on this port.
With counter polling enabled, this specifies the interval - in seconds - between
counter poller samples.
Click to save the changes.
Click to undo any changes made locally and revert to previously saved values.