I/O Control - EverFocus EMV400S FHD User Manual

4 channels 1080p full hd mobile dvr
Hide thumbs Also See for EMV400S FHD:
Table of Contents

Advertisement

6.9.5

I/O Control

The I/O Control setup menu is used to define the settings for controlling the mobile DVR
through RS-232 communication protocol. Please note that to perform the I/O function, the
optional accessory, External I/O Box, is required.
RS-232
Type: Select Control or Text Insert.
Baud Rate: This field is to set the speed at which is used to transmit instruction or information
through the RS-232 port on the mobile DVR. There are eight different speeds: 1200 BPS, 2400
BPS, 4800 BPS, 9600 BPS, 19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS.
Data Bit: This field is the data bit at which you will be transferring. There are two settings for
this option: 8 or 7.
Stop Bit: This field is to set the stop bit for the RS-232 connection. There are two different stop
bits, 1 or 2.
Parity: This field is to select the parity level at which you will be connected. You can choose
between None, Odd, or Even parity levels.
Note: For details on the RS-232 related settings, please consult the Technical Support
Department of EverFocus.
EMV400S FHD / EMV400SSD Mobile DVR