The table below outlines the BTU input rate of the wall furnace for
each flame level.
Heat Level
Single Tube
5 (HI)
4
3
2
1 (LO)
7.
After 45 to 70 seconds, the circulating air blower will acti-
vate. The circulating air blower speed will be set by the heat
level and will display on the Display Panel. See Figure 62.
Display Backlight
The display panel backlight will automatically turn off five sec-
onds after an input (either manual or remote) is acknowledged.
The backlight will automatically turn on when a new input is
acknowledged. To turn the backlight on manually, press the "Back-
light" button on the bottom left of the display panel. See Figure
24, page 18.
Shut Down Instructions
To off turn the wall furnace, simply set the thermostat to a set-
ting below the room temperature or push the display panel's mode
select button to "OFF". See Figure 15, page 11. DO NOT cut the
main electrical power to the wall furnace.
The circulating air blower will continue to operate after the burner
is turned off. The blower will stop automatically after 100 to 160
seconds to ensure the wall furnace has cooled sufficiently.
Page 38

WALL FURNACE INSTALLATION

INITIAL STARTUP AND ADJUSTMENTS
BTU Input
BTU Input
Double Tube
17,500
35,000
15,350
30,700
13,150
26,300
10,950
21,900
8,750
17,500
Table 4
Figure 62
Checking Manifold Pressure
Both Propane and Natural gas valves have a built-in pressure
regulator in the gas valve. See page 23 for a list of the normal high
and low manifold pressures.
A pressure tap accessible for test gauge connection is located on
the outlet side of the gas control.
Blower Operation
The circulating air blower will automatically engage and increase
in speed depending on the heat level. The circulating air blower
will start 45 to 70 seconds after ignition of the burner.
Once the wall furnace is turned off or the call for heat has been
satisfied, the circulating air blower will continue to run. The blower
will automatically turn off 100 to 160 seconds after the wall furnace
turns off to ensure proper cooling of the wall furnace.