Specifications And Dimensions - Empire Heating Systems PVS18N-3 Owner's Manual And Installation Instructions

Ultrasaver 90 plus series wall furnace
Table of Contents

Advertisement

Available languages

Available languages

Models
Maximum Input BTU/HR (KW/H)*
Minimum Input BTU/HR (KW/H)*
Height
Width
Depth with Shroud**
Gas Inlet (Pipe)
Electrical - The wall furnace comes equipped with a 5 foot (1.5m) 3 pronged cord exiting the rear left side of the wall furnace, for
connection to an approved 115 VAC, 60 Hz, 15A (maximum) wall receptacle. The Minimum Circuit Amp (MCA) is 8A, 920W and with
an accessory heated humidification tray installed, the MCA is 10A, 1150W.
Vent Pipe: 1-1/2 or 2 inch diameter pipe, 50 feet maximum equivalent length. See pages 26 and 29 to 32. The vent termination elbow
does not contribute to the overall vent length measurement.
* Input ratings are based on sea level operation and may vary at different elevations. No orifice change is required. The appliance will
de-rate automatically 1.5% per 1,000 feet.
** Add 3-3/8 inches for deep shroud.
All vent and combustion air pipes and fittings must be Schedule 40 PVC, ULC S636 and meet the ANSI/ASTM Standard D1785. Cement
must conform to ASTM Standard D2564. Empire-approved poly pipe with gasketed joints may also be used. Contact your Empire dealer
for availability.
Listed for Category IV venting.
Approved Alternate Vent Systems
Manufacturer
Duravent
Centrotherm
Page 16
INTRODUCTION

SPECIFICATIONS AND DIMENSIONS

SPECIFICATIONS
Vent System
PolyPro
InnoFlue
Dimensions - Figure 22
PVS18(N,P)
17,500 (5.13)
8,750 (2.56)
27-7/8"
36-1/8"
13
3/8" Pipe
PVS35(N,P)
35,000 (10.26)
17,500 (5.13)
27-7/8"
36-1/8"
13
3/8" Pipe
37873-0-0217