Lighting Instructions - Empire Heating Systems PVS18N-3 Owner's Manual And Installation Instructions

Ultrasaver 90 plus series wall furnace
Table of Contents

Advertisement

Available languages

Available languages

FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch any electrical switch
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's
phone.
Follow the gas supplier's instructions.
If you can not reach your gas supplier, call the fire
department.
1. STOP! Read the safety informa-
tion above.
2. Turn off the remote thermostat
if used.
3. Open bottom louver assembly, or
open the service access panel.
4. Turn off all electric power to the
appliance.
5. Turn gas line valve to "ON."
6. Wait five minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP!
Follow "A" in the safety information above. If you do not
smell gas, go to the next step.
7. Turn on all electric power to the appliance.
8. Turn on the remote thermostat if used, and set thermo-
stat to desired setting. If remote is not used, activate
the appliance using the display panel.
1. STOP! Read the safety information above.
2. Open bottom louver assembly, or open the service ac-
cess panel.
3. Turn off all electric power to the appliance.
37873-0-0217
WALL FURNACE INSTALLATION

LIGHTING INSTRUCTIONS

LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
B. Use only the wall switch or remote control switch to
turn the gas control on/off. Any attempted repairs or
adjustments should be performed by a qualified service
technician. Applying force or attempted repair may result
in a fire or explosion.
C. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
9. This appliance is equipped with an ignition device that
automatically lights the burner. Do not try to light the
burner by hand.
10. If the appliance will not operate, follow the instructions
"TO TURN OFF GAS TO APPLIANCE," and call your
service technician or gas supplier.
11. Close bottom louver assembly or close the service ac-
cess panel.
4. Turn gas line valve to "OFF."
5. Close bottom louver assembly, or close service access
panel.
OFF
ON
Page 33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvs18p-3Pvs35n-3Pvs35p-3