Technical Data
Maximum working pressure
Recommended Tip Size
Maximum Tip Size
Weight
Dimensions:
Length
Width
Height
Storage temperature range
Operating temperature range
Sound pressure level
Vibration level acceleration
Charger:
Charging time
Power source
Battery (Sealed Lead Acid):
Voltage (DC)
Capacity
Fuse
Current rating
Type
Pump damage will occur if fluid freezes in pump.
Damage to plastic parts may result if impact occurs in low temperature conditions.
Changes in paint viscosity at very low or very high temperatures can affect field marker performance.
† per ISO 3744 measured at 3.3 feet (1m)
†† per ISO 5349, no load condition
332119E
U.S.
1200 psi
LL5315
LL5417
60 lb
40 in.
23 in.
36 in.
33° to 120° F
33° to 120° F
79.2 dBa† sound pressure level
93.8 dBa† sound power level
2
Less than 5.5 feet/s
††
6 hours to 80%,
6 to 14 to 100%
120/240 VAC
12 V Maximum
22 Ah, 264 Wh
30 Amp
Automotive, Regular ATO
Technical Data
Metric
8.3 MPa, 83 bar
LL5315
LL5417
27.2 kg
101.6 cm
58.4 cm
91.4 cm
1° to 48° C
1° to 48° C
79.2 dBa† sound pressure level
93.8 dBa† sound power level
2
Less than 1.7 m/s
††
6 hours to 80%,
6 to 14 to 100%
120 /240VAC
12 V Maximum
22 Ah, 264 Wh
30 Amp
Automotive, Regular ATO