Repair

Tip Removal/Cleaning

1. Perform Pressure Relief Procedure, page 10.
ti20183a
2. Rotate spray tip (X) 1/4 turn and remove.
X
ti21497a
3. Wash tip in sink under running water. Use a brush
or pick to remove excess or dried material.
4. Use a pressurized air hose to blow out any remain-
ing material from tip. NOTE: You should be able to
clearly see through the tip hole when cleaned.
5. Install spray tip (X) and position to spray as shown
below.
X
ti21360a
332119E
X
ti21361a
CleanShot
Cleaning (If
applicable)
1. Perform Pressure Relief Procedure, page 10.
2. Remove spray tip/guard assembly (G).
G
ti21382a
3. Remove CleanShot assembly (Y).
Y
ti21383a
4. Use two wrenches to remove needle seat.