4.3.5. LIST OF MANDATORY COMPONENTS

Chimney
Components
Manufacturer
Must have rafter
protectors at the roof
Selkirk
level if the chimney
is enclosed at the
attic level
Rafter protector at the
roof level if chimney
is enclosed at the
attic level
Security chimney
Requires insulated
attic radiation shield
unless chimney is
enclosed at the attic
level
Roof radiation shield
M&G DuraVent
Attic insulation shield
Type / Brand
Part Number /
Product Code
Super Vent 2100
JSC8RRS (8")
CF Sentinel
Secure Temp S2100+
Ref. 8RS (8")
Ref. 8XRS (8")
Secure Temp ASHT+
Ref. 10XRS (10")
Secure Temp S2100+
Ref. 8RSA2 (8")
Ref. 8XRSA2 (8")
Secure Temp ASHT+
Ref. 8XRSA2 (10")
Order No. (8"): 8DT-RRS
Stock No. (8"):
810000264
DuraPlus HTC
Order No. (8"): 8DT-IS
Stock No. (8"):
810000263

4.4. MASONRY

4.4.1. T YPICAL EXISTING MASONRY
WARNING
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE. DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
You can install your appliance using your existing masonry chimney. To do
so, follow the guidelines below. If you are using a masonry chimney, it
is important that it be built in compliance with the specifications of the
Building Code in your region. It must normally be lined with fire clay bricks,
metal or clay tiles sealed together with fire cement. (Round flues are the
most efficient).
Remove the fireplace damper or fasten it permanently open.
We recommend the following method of sealing off the damper area
around the liner:
Measure the throat of the fireplace and mark this shape on a piece of 24
gauge sheet metal (flue cover); cut a six-inch (6 3/4" / 171mm) hole to
lie directly below the fireplace flue opening. Allow two inches of material
for a flange on all sides and cut to these measurements. Bend down the
flanges. If you have never done this before, it might be a good idea to make
a cardboard pattern and test it first. Fasten this flue cover in position as
high as possible with two masonry screws per side through the flanges into
the fireplace.
In Canada: Install flexible stainless steel liner from the top of the chimney
to the insert flue collar. Attach a stainless steel liner connector or elbow to
46