Table 5. 1xxxyyyy SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
1xxxyyyy
Description
Error Codes
2610
Power good (pGood) fault
2620
12V dc pGood input fault
2622
SMP expansion_comp_pgood
fault
2623
mezzanine_comp_pgood fault
2624
mezzanine_12V_pgood fault
2625
PCIE_A0_PGOOD fault
2626
PCIE_A1_PGOOD fault
18
JS12 Type 7998: Problem Determination and Service Guide
Action
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on
page 274.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on
page 274.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on
page 274.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on
page 274.
1. Go to "Checkout procedure" on page 186.
2. Replace the system-board and chassis assembly, as described in
"Replacing the Tier 2 system-board and chassis assembly" on
page 274.
Perform the DTRCARD Symbolic CRU isolation procedure by
completing the following steps:
1. Reseat the PCIe expansion card.
2. If the problem persists, replace the expansion card.
3. If the problem persists, go to "Checkout procedure" on page
186.
4. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the Tier 2 system-board
and chassis assembly" on page 274.
The DTRCARD Symbolic CRU isolation procedure is in "Service
processor problems" on page 205.
Perform the DTRCARD Symbolic CRU isolation procedure by
completing the following steps:
1. Reseat the PCIe expansion card.
2. If the problem persists, replace the expansion card.
3. If the problem persists, go to "Checkout procedure" on page
186.
4. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the Tier 2 system-board
and chassis assembly" on page 274.
The DTRCARD Symbolic CRU isolation procedure is in "Service
processor problems" on page 205.