Microprocessor problems

Identify microprocessor problem symptoms and what corrective actions to take.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Symptom
The blade server will not boot
or a checkpoint or firmware
error code is logged in the
management-module event log
(the startup microprocessor is
not working correctly)

Monitor or video problems

View monitor or video problem symptoms to find corrective actions.
Some IBM monitors have their own self-tests. If you suspect a problem with your
monitor, see the documentation that comes with the monitor for instructions for
testing and adjusting the monitor. If you cannot diagnose the problem, call for
service.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, Type 7998," on page 235 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Symptom
The screen is blank.
Only the cursor appears.
198
JS12 Type 7998: Problem Determination and Service Guide
Action
1. If a checkpoint or firmware error was logged in the management module event
log, correct that error.
2. If no error was logged, restart the blade server and check the management
module event log again for error codes.
3. Replace the system-board and chassis assembly.
Action
1. Make sure that:
v The keyboard/video select button LED on the front of the blade server is lit,
indicating that the blade server has ownership of the keyboard and video.
v The monitor cables are connected properly.
v The monitor is turned on and the Brightness and Contrast controls are
adjusted correctly.
v The blade server is using a supported operating system, as described on the
ServerProven Web site, and that the operating system has loaded completely.
2. If you have verified these items and the screen remains blank, replace:
a. Monitor
b. Management module on the BladeCenter unit. See the online information
or the Hardware Maintenance Manual and Troubleshooting Guide or Problem
Determination and Service Guide for your BladeCenter unit.
Make sure that the keyboard/video ownership on the BladeCenter unit has not
been switched to another blade server. If the problem remains, see "Solving
undetermined problems" on page 231.