Maximum Power Available for 3.5-kW Inputs (DC)

Power Inputs
1 input (277 V)
1 input (220/230
V)
1 input (210 V)
1 input (110 V)
A combination of 3-kW AC and 3.5-kW HVAC/HVDC power supplies can be used.
Note
Maximum Power Available for 3.5-kW Inputs (DC)
The maximum power available for operations depends on the input power from your power source, the number
and output capabilities of your power supplies, and the power redundancy mode that you use. The following
table lists the amount of power available for 3.5-kW HVAC/HVDC power supplies depending on DC power
inputs, number of power supplies, and the mode used.
Power Inputs
1 input (380
V)
1 input (210
V)
Cisco Nexus 7702 Hardware Installation Guide
78
Power Supplies
Combined Mode
1
3500 W
2
7000 W
1
3500 W
2
7000 W
1
3100 W
2
6200 W
1
1500 W
2
3000 W
Power
Combined
Supplies
Mode
1
3,500 W
2
7,000 W
1 input
1
(220/240 V)
2
1
2
Power Supply
Input Source
Redundancy
Redundancy
Mode
Mode
3500 W
3500 W
3500 W
3500 W
3100 W
3100 W
1500 W
1500 W
Power Supply
Input Source
Redundancy
Redundancy
Mode
Mode
3,500 W
3,500 W
3,500 W
7,000 W
3,500 W
3,100 W
6,200 W
3,100 W
Switch Specifications
Full Redundancy
Mode
3500 W
3500 W
3100 W
1500 W
Full
Redundancy
Mode
3,500 W
3,500 W
3,500 W
3,100 W
3,100 W