Configure a Custom Test as follows:
On the last page of the SETUP mode, CONFIGURE CUSTOM TEST,
1.
select a Custom Cable from the list; then press E.
If you want to edit the name of the custom test, press E; then use the
2.
alphanumeric display to enter a new name. Press SAVE when the name
change is completed.
3.
Set the initial values for your custom test by selecting the desired standard
and cable type under USE DEFAULT VALUES FROM:.
To see and change other parameters use Page Down, Page Up and
4.
the cursor up and down keys to select the desired item. Press E, make
the change, press E again to retain the desired change. Pressing
EXIT discards the change.
Press e to exit the custom fiber test screens.
Press ! ABORTto exit the custom fiber test setup screens without
saving any changes.
Press @ Set to Default to reset a value to the initial value for
the selected standard.

Fiber Test Reports

Fiber test reports can be saved, viewed, printed, and uploaded to a PC in the
same way as other DSP-4000 test reports. See Chapter 5 in the DSP-4000
Users Manual for more information.

Maintenance

Clean the case with a soft cloth dampened with water or a mild detergent. Do
not use abrasives or solvents.
Clean the optical connectors as described under "Cleaning the Fiber
Connections". Always cover the connectors with a dust cap when not in use.
Fiber Test Adapter
Fiber Test Reports