Standard Muting Mode With F3W-Ma; Nector) - Omron F3SG series User Manual

Safety light curtain
Hide thumbs Also See for F3SG series:
Table of Contents

Advertisement

Input/Output Circuit and Applications
5-2-9. Standard Muting Mode with F3W-MA (T-Shaped
Configuration with 4-Joint Plug/Socket Connector)
The following is the example of F3SG-RA with Scan Code B, External Device Monitoring disabled,
Auto Reset mode, PNP output and External Test in 24 V Active, and F3W-MA with Scan Code A,
Chattering and Void Space Prevention 1, Off-Delay 100 ms and Muting Enable disabled.
[DIP Switch settings]*1
F3SG-RA
F3W-MA
Primary
F3W-MA
Secondary
Configure functions with the DIP Switches before wiring.
[Wiring Example]
F3W-MA Emitter
(Primary)
F39-GCN4-L
S1: Test Switch (Connect the line to 0 V if this switch is not required)
S2: Lockout/Interlock Reset Switch, Override Switch or Override Cancel Switch
ML: Muting lamp
*1. The functions are configurable with DIP Switch. For the DIP Switch of the F3SG-RA, refer to the Chapter 3 Setting with DIP
Switch. For the DIP Switch of the F3W-MA, refer to the Smart Muting Actuator F3W-MA Series User's Manual.
*2. DIP Switch Bank 2 of F3W-MA receiver is not used.
*3. Also used as Override input line.
*4. Make sure to connect an override cancel switch to the Reset line when using the override function. Otherwise the override state
may not be released by the override cancel switch, resulting in serious injury.
*5. Refer to 5-4. Connectable Safety Control Units for more information.
*6. The safety controller and the F3SG-R must share the power supply or be connected to the common terminal of the power
supply.
F3SG-R
192
User's Manual
Scan Code B
EDM Disabled (factory default setting)
Receiver
Auto Reset (factory default setting)
PNP (factory default setting)
Scan Code B
Emitter
External Test: 24 V Active (factory default setting)
Scan Code A
Chattering and Void Space Prevention 1
Receiver
Off-Delay 100 ms
Muting Enable Disabled (factory default setting)
Emitter
Scan Code A
Receiver
Emitter
F3W-MA Emitter
(Secondary)
F39-JG
A-L
S1
Function
-
F3W-MA Receiver
F3W-MA Receiver
(Primary)
(Secondary)
F39-GCN4-D
F39-JG
A-D
S2
ML
*4
IN1
Safety
Controller *5 *6
DIP-SW1
DIP-SW2
-
-
-
No setting
No setting
required
required
: Indicates a switch position.
+24 VDC
Power Supply
0 VDC
IN2
*2
*2
*2
*2
*2
*2