Wiring/Installation
4-1-3. Distance from Reflective Surfaces
Install the sensor system so that it is not affected by reflective surfaces. Failure to do so
may hinder detection, resulting in serious injury.
Install the sensor system at distance D or further from highly reflective surfaces such as metallic walls,
floors, ceilings, or workpieces, as shown below.
4-1-3-1. F3SG-4R (Type 4 ESPE)
Emitter
Distance between an emitter and a
receiver (operating range L)
0.3 to less than 3 m
3 m or more
4-1-3-2. F3SG-2R (Type 2 ESPE)
Emitter
Distance between an emitter and a
receiver (operating range L)
0.3 to less than 3 m
3 m or more
F3SG-R
126
User's Manual
Reflective ceiling
D
Receiver
Detection zone
L
D
Reflective floor
Allowable installation distance
D
0.13 m
L/2 x tan5 ° = L x 0.044 m
Reflective ceiling
D
Receiver
Detection zone
L
D
Reflective floor
Allowable installation distance
D
0.26 m
L/2 x tan10 ° = L x 0.089 m
Reflective surface
D
Emitter
5
5
L
Reflective surface
D
Emitter
10
10
L
Receiver
Receiver