Distance From Reflective Surfaces; F3Sg-4R (Type 4 Espe); F3Sg-2R (Type 2 Espe) - Omron F3SG series User Manual

Safety light curtain
Hide thumbs Also See for F3SG series:
Table of Contents

Advertisement

Wiring/Installation

4-1-3. Distance from Reflective Surfaces

Install the sensor system so that it is not affected by reflective surfaces. Failure to do so
may hinder detection, resulting in serious injury.
Install the sensor system at distance D or further from highly reflective surfaces such as metallic walls,
floors, ceilings, or workpieces, as shown below.
4-1-3-1. F3SG-4R (Type 4 ESPE)
Emitter
Distance between an emitter and a
receiver (operating range L)
0.3 to less than 3 m
3 m or more
4-1-3-2. F3SG-2R (Type 2 ESPE)
Emitter
Distance between an emitter and a
receiver (operating range L)
0.3 to less than 3 m
3 m or more
F3SG-R
126
User's Manual
Reflective ceiling
D
Receiver
Detection zone
L
D
Reflective floor
Allowable installation distance
D
0.13 m
L/2 x tan5 ° = L x 0.044 m
Reflective ceiling
D
Receiver
Detection zone
L
D
Reflective floor
Allowable installation distance
D
0.26 m
L/2 x tan10 ° = L x 0.089 m
Reflective surface
D
Emitter
5
5
L
Reflective surface
D
Emitter
10
10
L
Receiver
Receiver