System Operation and Functions
2-15-4. Setting with Configuration Tool
Some settings of functions configurable with the Configuration Tool may increase risks.
Make sure the Responsible Person conduct a thorough risk assessment analysis before
managing and changing the settings. Unintended changes to the settings may cause a
person to go undetected, resulting in serious injury.
The user can make changes to the settings by the Configuration Tool.
Setting is required for each sensor segment in case of a cascade connection.
Function
Floating Blanking
Floating Blanking Monitoring
Temporarily Disable Monitoring
Function
Monitoring temporarily disabled
time limit
Number of floating beams
Number of allowable beams
Make sure the Position 8 of the DIP Switch is set to Configuration Tool Enabled to activate the settings by the
Configuration Tool.
Setting the Floating Blanking Monitoring function to Disable Monitoring may create an undetectable area where a person
can interrupt the F3SG-RA without being detected, and it is not compliant with IEC 61496-2. Conduct risk assessment
analysis thoroughly before enabling this setting.
Refer to Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User's Manual for more
information on setting this function by the Configuration Tool.
F3SG-R
84
User's Manual
Factory Default Setting
Disable
Enable/Disable
Lockout
Disable monitoring/Lockout/Cancel blanking zone
Disable
Enable/Disable
10 s
1 to 200 s (1-s increments), or infinite
1
1 to 15 (1-beam increments)
0
0 to 5 (1-beam increments)
Available Parameters