Bbu Bracket Installation / Removal; Bbu Bracket Installation; Figure 127. Installing The Bbu Bracket - Intel P4304XXMFEN2 Service Manual

Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
3.9

BBU Bracket Installation / Removal

The Battery Backup Unit (BBU) bracket (iPC – AXXSTBBUBRKT) is an optional accessory kit that supports up
to 3 Raid Maintenance Free Backup Units (RMFBU) and can be installed in any of the 5.25" device bays.
®
Refer to the Intel
Server Board S2600ST Product Family Configuration guide to see available RMFBU kits.
3.9.1

BBU Bracket Installation

1. Remove the chassis side cover by following the instructions in Section 1.2.1.
2. Remove the EMI shield in the drive bay by following instructions in section 3.1.1.
3. Locate the slides from the chassis side (see letter A). Attach the slides to the BBU bracket by
pressing the slides firmly into the side dimples on the BBU bracket (see letter B). Insert the
bracket/slide assembly into the device bay until the slides lock into place (see letter C).
98

Figure 127. Installing the BBU Bracket