8. Cable connections.
S2600CW Server Board Family:
Note: The following instructions apply when using the on-board connectors.
Figure 62. Connecting Data Cables for Hot-Swap Drive Bay Kit – S2600CW Board Family
a. If using a 4x3.5 Hot-Swap Drive Bay, connect the Mini-SAS HD cable connector to the server board
connector labeled as sSATA_0-3 or SATA_0-3. If using an 8x2.5 Hot-Swap Drive Bay, connect the
Mini-SAS HD cable connector to both sSATA_0-3 and SATA_0-3.
Notes: The SAS_0-3 and SAS_4-7 are available on S2600CW2S and S2600CWTS.
S2600ST Server Board Family:
Figure 63. Connecting Data Cables for Hot-Swap Drive Bay Kit – S2600ST Board Family
a. If using a 4x3.5 Hot-Swap Drive Bay, connect the Mini-SAS HD cable connector to the server board
connector labeled as SATA_0-3 or SATA_4-7. If using an 8x2.5 Hot-Swap Drive Bay, connect the Mini-
SAS HD cable connector to both SATA_0-3 and SATA_4-7.