Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
2.3

Storage Device Installation/Upgrade

The server chassis P4304XXMFEN2 and P4304XXMUXX support several different storage device options
depending on the installed server board. This section provides instructions for the installation and upgrade of
front drive bay storage devices. Installation of other storage options available through accessory kits is
provided in Chapter 3.
Note: To maintain proper system cooling, you must populate all externally accessible drive bays with a drive
carrier. Each drive carrier must have a hard disk drive (HDD), Solid State Device (SSD), or a supplied drive
blank installed.
For S2600CW board family:
Basic Configuration: Four 3.5" fixed drive trays are the default chassis configuration.
Upgrade Option: One 3.5" drive bay with Hot-Swap backplane. Supports up to 4x3.5" drives.
Upgrade Option: Two 3.5" drive bays with Hot-Swap backplanes. Support up to 8x3.5 drives.
Basic Configuration
40
4x3.5 Upgrade Option
8x3.5 Upgrade Option