Figure 12. Server Board Installation - Intel P4304XXMFEN2 Service Manual

Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
1. Carefully move aside any cables taped to the chassis base to clear the area for server board
placement.
2. Carefully lower the server board into the chassis so that the rear I/O connectors of the server
board align with it and are fully seated into the matching holes on the chassis back panel (see
letter A).
3. The server board is accurately placed when rear I/O connectors (NIC connectors, USB connectors,
and VGA connector) align with the IO shield openings and properly fit into it.
4. Fasten down the server board with nine screws using 8 in/lbs torque (see letter B).
12

Figure 12. Server Board Installation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4304xxmuxx

Table of Contents