Replacing The Server Board; Server Board Removal; Figure 154. Server Board Removal - Intel P4304XXMFEN2 Service Manual

Hide thumbs Also See for P4304XXMFEN2:
Table of Contents

Advertisement

Intel
®
Server Chassis P4304XXMFEN2/P4304XXMUXX Product Family System Integration and Service Guide
7.4

Replacing the Server Board

7.4.1

Server Board Removal

1.
Power off system and remove power cords from each power supply module installed.
2.
Disconnect all externally attached cables.
3.
Remove the chassis side cover by following instructions in section 1.2.1
4.
Remove air duct by following instructions in section 1.2.2.1.
5.
Disconnect all cables attached to PCIe* add-in cards (if installed).
6.
Remove all options installed onto the server board including (if installed): Intel® RAID 5 option key, Intel®
RMM 4 Lite key, TPM Module, and any installed PCIe* add-in cards.
7.
Remove processors by following instructions in section 2.1.
8.
Remove all DIMMs by following instructions in section 2.2.3.
9.
Disconnect and clear from the server board area all cables attached to connectors on the server board
10. Remove nine screws used to secure the server board to the chassis (see Letter A).
11. Carefully lift the server board from the chassis and place it into an anti-static bag (see letter B).
136

Figure 154. Server Board Removal