The page includes the following fields:
Object
• Enable
• LLDP PDU Disable
Action
• Transmission Interval
• Check-Change Interval
• Reinitialization Delay
• Transmit Delay
LLDP-MED Fast Start
Repeat Count
User's Manual of GS-4210-16T2S_24T2S_16P2S_24P2S_48T4S
Description
Enable or disable LLDP globally function.
Set LLDP PDU disable action: include "Filtering", "Bridging" and "Flooding".
Filtering: discrad all LLDP PDU.
Bridging: transmit LLDP PDU in the same VLAN.
Flooding: transmit LLDP PDU for all port.
The switch is periodically transmitting LLDP frames to its neighbors for having the
network discovery information up-to-date. The interval between each LLDP
frame is determined by the Transmission Interval value. Valid values are
restricted to 5 - 32768 seconds.
Default: 30 seconds
This attribute must comply with the following rule:
(Transmission Interval * Hold Time Multiplier) ≤65536, and Transmission Interval
>= (4 * Delay Interval)
Each LLDP frame contains information about how long the information in the
LLDP frame shall be considered valid. The LLDP information valid period is set to
Holdtime multiplied by Transmission Interval seconds. Valid values are
restricted to 2 - 10 times.
TTL in seconds is based on the following rule:
(Transmission Interval * Holdtime Multiplier) ≤ 65536.
Therefore, the default TTL is 4*30 = 120 seconds.
When a port is disabled, LLDP is disabled or the switch is rebooted a LLDP
shutdown frame is transmitted to the neighboring units, signaling that the LLDP
information isn't valid anymore. Tx Reinit controls the amount of seconds
between the shutdown frame and a new LLDP initialization. Valid values are
restricted to 1 - 10 seconds.
If some configuration is changed (e.g. the IP address) a new LLDP frame is
transmitted, but the time between the LLDP frames will always be at least the
value of Transmit Delay seconds. Transmit Delay cannot be larger than 1/4 of
the Transmission Interval value. Valid values are restricted to 1 - 8192 seconds.
This attribute must comply with the rule:
(4 * Delay Interval) ≤Transmission Interval
Configures the amount of LLDP MED Fast Start LLDPDUs to transmit during the
activation process of the LLDP-MED Fast Start mechanisim.
Range: 1-10 packets;