Special D
Counter
Interrupt signal X1(I100/I101)
2. Function:
a) When X0 (counter input) and X1 (external Interrupt) correspondingly work together with
C243, and I100/I101, PLC will move the count value to D1241 and D1240.
b) When X0 (counter input) and X4 (external Interrupt) correspondingly work together with
C246, C248, C252 and I400/I401, PLC will move the count value to D1241 and D1240
c) When X2 (counter input) and X3 (external Interrupt) correspondingly work together with
C244, and I300/I301, PLC will move the count value to D1243 and D1242.
d) When X2 (counter input) and X5 (external Interrupt) correspondingly work together with
C250, C254 and I500/I501, PLC will move the count value to D1243 and D1242.
Example:
When external interrupt (X1, I101) occurs during counting process of C243, the count value in
C243 will be stored in (D1241, D1240) and C243 is reset. After this, the interrupt subroutine I101
will be executed
Function Group

Enabling force-ON/OFF of input point X

Number
M1304
Contents:
When M1304 = ON, WPLSoft or ISPSoft can set ON/OFF of input pont X, but the associated
hardware LED will not respond to it.
Function Group
Output specified pulses or seek Z phase signal when zero point is achieved.
Number
M1308, D1312
Contents:
When zero point is achieved, PLC can output specified pulses or seek Z phase signal by this
function. Input terminals X2, X3 are the Z-phase signal input point of CH1, CH2. When M1308= ON,
D1312 is the setting register to specify the additional pulses within the range -30,000~30,000.
Specified value exceeds the range will be changed as the max/min value automatically. When
D1312 is set to 0, the additional pulses output function will be disabled.
Functions of other input terminals:
X4 → CH1 DOG signal input
X5 → CH1 LSN signal input
Function Group

ID of right side modules on ES2/EX2/SS2/SA2/SX2/SE

Number
D1320~ D1327
Contents:
When right side modules are connected on ES2/EX2, the ID of each I/O module will be stored in
D1320~D1327 in connection order.
ID of each special module:
Name
DVP04AD-E2
DVP02DA-E2
DVP04DA-E2
2 - 5 6
D1241, D1240
C243
C246
C248
X4(I400/I401)
M1000
DCNT
M1000
I101
DMOV
ID (HEX)
H'0080
H'0041
H'0081
C252
C244
X3(I300/I301)
EI
C243
K100
FEND
D1240
D0
IRET
END
X6 → CH2 DOG signal input
X7 → CH2 LSN signal input
Name
DVP06XA-E2
DVP04PT-E2
DVP04TC-E2
D1243, D1242
C250
C254
X5(I500/I501)
ID (HEX)
H'00C4
H'0082
H'0083