A10: Logic Power Input - Delta PBC Series User Manual

Power brick controller
Table of Contents

Advertisement

Power Brick Controller User Manual

A10: Logic Power Input

A10 is used to bring in the 24 Volt DC supply powering up the logic portion of the Power Brick Controller.
This power can remain on regardless of the main AC bus power, allowing the signal electronics to be active
while the main motor power is passive.
Caution
The 24-Volt (±5%) power supply unit must be capable of providing 5 amperes per Power Brick Controller.
If multiple drives are sharing the same 24-Volt power supply, it is highly recommended to wire each drive
back to the power supply terminals separately. This connection can be made using a 22 AWG wire directly
from a protected power supply.
A10: 3-pin Female
Mating: 3-pin Male
Pin #
Symbol
1
+24 VDC
2
+24 VDC RET
3
CHGND
Phoenix Contact mating connector part# 1777293
Note
Connections and Software Setup
The 24 VDC logic power must always be applied before applying
main AC bus power.
Function
Input
Logic power input +
Common
Logic power return -
Ground
Chassis ground
24 VDC (±5%)
Power Supply
Chassis ground (pin #3) and +24 VDC RET (pin #2) are tied together
internally.
1
2
Description
+24 VDC (±5 %)
Connect to Power Supply Return
Connect to Protection Earth
1
2
24 V
0 V
3
Notes
3
33

Advertisement

Table of Contents
loading

Table of Contents