Table 1-2 Relations between the timers
Timer
Hold
Join
Leave
LeaveAll
The following are recommended GVRP timer settings:
GARP hold timer: 100 centiseconds (1 second)
GARP Join timer: 600 centiseconds (6 seconds)
GARP Leave timer: 3000 centiseconds (30 seconds)
GARP LeaveAll timer: 120000 centiseconds (2 minutes)
Configuring GVRP Port Registration Mode
Follow these steps to configure GVRP port registration mode:
To do ...
Enter system view
Enter Ethernet port view
Configure GVRP port
registration mode
Lower threshold
10 centiseconds
This lower threshold is greater
than or equal to twice the
timeout time of the Hold timer.
You can change the threshold
by changing the timeout time of
the Hold timer.
This lower threshold is greater
than twice the timeout time of
the Join timer. You can change
the threshold by changing the
timeout time of the Join timer.
This lower threshold is greater
than the timeout time of the
Leave timer. You can change
threshold by changing the
timeout time of the Leave timer.
Use the command ...
system-view
interface interface-type
interface-number
gvrp registration { fixed |
forbidden | normal }
1-6
Upper threshold
This upper threshold is less
than or equal to one-half of the
timeout time of the Join timer.
You can change the threshold
by changing the timeout time of
the Join timer.
This upper threshold is less
than one-half of the timeout
time of the Leave timer. You
can change the threshold by
changing the timeout time of
the Leave timer.
This upper threshold is less
than the timeout time of the
LeaveAll timer. You can
change the threshold by
changing the timeout time of
the LeaveAll timer.
32,765 centiseconds
Remarks
—
—
Optional
By default, GVRP port
registration mode is normal.