1
1-13. Capacity Table
1. Cooling Capacity Performance Data
•
Combination of Multiple Unit
Ceiling Type
Power
Model
Source
220V
230V
S-60PT2E5A×2
240V
U-125PE1E5A
50Hz
(U-125PE1E8A)
1phase
(3phase)
220V
230V
S-50PT2E5A×3
240V
U-140PE1E5A
50Hz
(U-140PE1E8A)
1phase
(3phase)
220V
230V
S-71PT2E5A×2
240V
U-140PE1E5A
50Hz
(U-140PE1E8A)
1phase
(3phase)
Ambient
Return
25°C
Air
DB
WB
TC
SHC
IPT
16
12.7
9.9
3.94
12.7
23
19
13.6
7.5
4.11
13.6
22
14.9
5.2
4.26
14.9
16
13.2
11.8
4.01
13.2
25
19
14.1
9.3
4.18
14.1
22
15.4
6.9
4.33
15.4
16
13.6
13.6
4.08
13.6
27
19
14.6
11.2
4.25
14.6
22
16.0
8.9
4.40
16.0
16
13.8
13.8
4.09
13.8
29
19
14.8
13.0
4.26
14.8
22
16.2
10.6
4.41
16.2
16
14.0
14.0
4.10
14.0
32
19
15.0
13.1
4.27
15.0
22
16.4
10.7
4.42
16.4
16
13.6
10.6
4.58
13.6
23
19
14.6
8.0
4.78
14.6
22
16.0
5.6
4.95
16.0
16
14.1
12.5
4.66
14.1
25
19
15.1
9.9
4.86
15.1
22
16.5
7.4
5.03
16.5
16
14.6
14.6
4.74
14.6
27
19
15.6
11.9
4.94
15.6
22
17.1
9.4
5.11
17.1
16
14.8
14.8
4.75
14.8
29
19
15.8
13.8
4.96
15.8
22
17.3
11.3
5.13
17.3
16
15.0
15.0
4.76
15.0
32
19
16.1
14.0
4.97
16.1
22
17.6
11.5
5.14
17.6
16
13.6
10.3
4.58
13.6
23
19
14.6
8.1
4.78
14.6
22
16.0
5.7
4.95
16.0
16
14.1
12.2
4.66
14.1
25
19
15.1
9.8
4.86
15.1
22
16.5
7.4
5.03
16.5
16
14.6
14.2
4.74
14.6
27
19
15.6
11.7
4.94
15.6
22
17.1
9.2
5.11
17.1
16
14.8
14.8
4.75
14.8
29
19
15.8
13.3
4.96
15.8
22
17.3
11.0
5.13
17.3
16
15.0
15.0
4.76
15.0
32
19
16.1
13.6
4.97
16.1
22
17.6
11.2
5.14
17.6
Outdoor air intake temp(°C D.B.)
30°C
35°C
TC
SHC
IPT
TC
SHC
9.9
4.24
12.2
9.5
7.5
4.42
13.1
7.3
5.1
4.57
14.3
5.0
11.8
4.31
12.7
11.4
9.4
4.49
13.5
9.0
7.0
4.65
14.8
6.7
13.6
4.38
13.1
13.1
11.2
4.57
14.0
10.8
8.8
4.73
15.3
8.4
13.8
4.39
13.3
13.3
13.1
4.58
14.2
12.6
10.5
4.74
15.6
10.3
14.0
4.40
13.5
13.5
13.2
4.59
14.4
12.8
10.7
4.75
15.8
10.4
10.6
4.93
13.1
10.3
8.1
5.14
14.0
7.8
5.6
5.32
15.4
5.4
12.5
5.01
13.6
12.2
10.0
5.22
14.5
9.6
7.5
5.40
15.9
7.2
14.6
5.09
14.0
14.0
12.0
5.31
15.0
11.6
9.4
5.49
16.4
9.1
14.8
5.10
14.3
14.3
13.9
5.32
15.2
13.4
11.3
5.51
16.7
10.9
15.0
5.12
14.5
14.5
14.1
5.34
15.4
13.6
11.5
5.52
16.9
11.0
10.4
4.93
13.1
10.1
8.0
5.14
14.0
7.7
5.7
5.32
15.4
5.4
12.2
5.01
13.6
11.9
9.8
5.22
14.5
9.5
7.5
5.40
15.9
7.2
14.2
5.09
14.0
13.8
11.6
5.31
15.0
11.2
9.3
5.49
16.4
8.9
14.8
5.10
14.3
14.3
13.4
5.32
15.2
13.0
11.0
5.51
16.7
10.7
15.0
5.12
14.5
14.5
13.7
5.34
15.4
13.1
11.2
5.52
16.9
10.9
1-412
TC
:Cooling Capacity
SHC :Sensible Heat Capacity
IPT :Cooling Power Consumption
40°C
IPT
TC
SHC
IPT
TC
4.51
11.4
9.4
4.69
8.3
4.70
12.2
6.9
4.89
8.9
4.86
13.3
4.6
5.06
9.7
4.58
11.8
11.2
4.77
8.6
4.78
12.6
8.7
4.97
9.2
4.95
13.8
6.4
5.14
10.1
4.66
12.2
12.2
4.85
8.9
4.86
13.0
10.5
5.05
9.5
5.03
14.3
8.2
5.23
10.4
4.67
12.4
12.4
4.86
9.0
4.87
13.2
12.4
5.07
9.7
5.04
14.5
10.1
5.24
10.6
4.68
12.6
12.6
4.87
9.2
4.88
13.4
12.6
5.08
9.8
5.05
14.7
10.2
5.25
10.7
5.24
12.2
10.0
5.45
8.9
5.47
13.0
7.4
5.68
9.5
5.65
14.3
4.9
5.88
10.4
5.33
12.6
11.9
5.54
9.2
5.56
13.5
9.3
5.78
9.9
5.75
14.8
6.8
5.98
10.8
5.42
13.1
13.1
5.63
9.5
5.65
14.0
11.4
5.88
10.2
5.85
15.3
8.8
6.08
11.2
5.43
13.3
13.3
5.65
9.7
5.66
14.2
13.3
5.89
10.4
5.86
15.5
10.6
6.09
11.3
5.44
13.4
13.4
5.66
9.8
5.68
14.4
13.4
5.91
10.5
5.87
15.7
10.7
6.11
11.5
5.24
12.2
9.7
5.45
8.9
5.47
13.0
7.3
5.68
9.5
5.65
14.3
5.0
5.88
10.4
5.33
12.6
11.6
5.54
9.2
5.56
13.5
9.1
5.78
9.9
5.75
14.8
6.8
5.98
10.8
5.42
13.1
13.1
5.63
9.5
5.65
14.0
11.1
5.88
10.2
5.85
15.3
8.6
6.08
11.2
5.43
13.3
13.3
5.65
9.7
5.66
14.2
12.8
5.89
10.4
5.86
15.5
10.3
6.09
11.3
5.44
13.4
13.4
5.66
9.8
5.68
14.4
12.9
5.91
10.5
5.87
15.7
10.4
6.11
11.5
unit : kW
46°C
SHC
IPT
7.8
3.83
5.5
4.00
3.4
4.13
8.6
3.90
7.3
4.06
5.0
4.20
8.9
3.96
9.0
4.13
6.6
4.27
9.0
3.97
9.7
4.14
8.4
4.28
9.2
3.98
9.8
4.15
8.5
4.29
8.5
4.45
5.9
4.65
3.6
4.81
9.2
4.53
7.8
4.72
5.3
4.89
9.5
4.60
9.7
4.80
7.2
4.97
9.7
4.62
10.4
4.81
8.9
4.98
9.8
4.63
10.5
4.83
9.1
4.99
8.2
4.45
5.8
4.65
3.7
4.81
9.2
4.53
7.6
4.72
5.3
4.89
9.5
4.60
9.3
4.80
7.0
4.97
9.7
4.62
10.4
4.81
8.5
4.98
9.8
4.63
10.5
4.83
8.7
4.99