Single-Type
1-1. Unit Specifications
PEY1
4. Low Silhouette Ducted Type S-60PF1E5A / U-60PEY1E5
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL kWh*4
O
TOTAL(W/W)*5/("A"~"G")
EER/EER CLASS
O
Pdsign
L
Erp
SEER
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
dB-A (H/M/L)
NOISE INDOOR
Power Level dB
dB-A (H/L)
NOISE OUTDOOR
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL kWh*4
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
*6
Annual consumption
N
Class
G
POWER FACTOR
dB-A (H/M/L)
NOISE INDOOR
Power Level dB
dB-A (H/L)
NOISE OUTDOOR
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
3
COOL
m
/min (ft
I/D AIR
3
FLOW
HEAT
m
/min (ft
3
O/D AIR
COOL
m
/min (ft
3
FLOW
HEAT
m
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Cool (DBT)
Condition
Heat (DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
ADD GAS AMOUNT g/m (oz/ft)
N
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air flow volume in (l/s), the value in (m
*2: If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-60PF1E5A
-
ø, Hz
1ø 50Hz
V
220
230
kW
6.0
6.0
20500
20500
A
0.91
0.89
W
120
120
-
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
35/32/26
57/54/48
kW
6.0
6.0
20500
20500
A
0.91
0.89
W
120
120
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
35/32/26
57/54/48
-
-
1.26/160
1.20/160
-
-
-
120
L/h(Pt/h)
3.4
Pa
70 (MIN10 - MAX150)
3
/min)
21/19/15 (742/671/530)
3
/min)
21/19/15 (742/671/530)
3
/min)
3
/min)
290 (11-13/32)
1000 (39-3/8)
700 (27-9/16)
355
1214
850
33 (73)
41 (91)
9 (10)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
flared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-60PEY1E5
-
ISO13253 / EN14511 / EN14825 / EN12102
1ø 50Hz
240
220
230
6.0
20500
0.87
9.00
8.65
120
1.810k
1.810k
1.930k
1.930k
965
965
-
3.10
3.10 / B
-
-
6.0
-
-
5.4
-
-
389
-
-
A
-
91
91
46/-
65/-
6.0
20500
0.87
6.40
6.10
120
1.290k
1.290k
1.410k
1.410k
-
4.25
4.25 / A
-
-
5.0
-
-
-9
-
-
3.8
-
-
1842
-
A
A
-
92
92
-
-
50/-
69/-
-
1.15/160
18/3.64k
18/3.77k
-
9.00/1.8k
8.65/1.8k
-
90
(7.1)
-
30
35
R410A
1.70k
569 (22-13/32)
790 (31-7/64)
285 (11-7/32)
645
921
386
42 (93)
46 (101)
4 (5)
-10°C ~ 43°C
-15°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
flared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164)
(49.2/98.4)
40
(0.430)
20
(65.6)
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
3
1-179
240
Min
Max
2.0
7.0
6800
23900
8.30
-
-
1.810k
-
-
1.930k
325
2.850k
965
-
-
3.10
6.15
2.46
-
-
-
-
91
-
-
1.8
7.0
6100
23900
5.90
-
-
1.290k
-
-
1.410k
275
2.055k
4.25
6.55
3.41
-
-
-
-
A
91
-
-
⁄
⁄
⁄
⁄
18/3.93k
⁄
8.30/1.8k
⁄
⁄
(1067)
(1229)
(60.0)
/
/
/
/
/
/
/
/
/
~
~
1