TECHNICAL DATA & SERVICE MANUAL
R410A Models
Model No.
Indoor Units
Indoor
Type
Units Type
U1
4-Way Cassette
4-Way Cassette
Y1
60×60
T1
Ceiling
T2
Ceiling
K1
Wall Mounted
Low Silhouette
F1
Ducted
N1
Ducted
Outdoor Units
Type
Outdoor Units Type
Single Split (1-phase)
PE1
Single Split (3-phase)
Single Split (1-phase)
PEY1
Single Split (3-phase)
85464849311007
Indoor Unit
4-Way Cassette
4-Way Cassette 60×60
Ceiling
Wall Mounted
Low Silhouette Ducted
Ducted
36
45
S-36PU1E5
S-45PU1E5
S-50PU1E5
S-36PY1E5
S-45PY1E5
S-36PT1E5
S-45PT1E5
S-36PT2E5
S-45PT2E5
S-36PK1E5
S-45PK1E5
S-50PK1E5
S-36PF1E5
S-45PF1E5
S-36PN1E5
S-45PN1E5
S-50PN1E5
50
U-50PE1E5
50
60
S-60PU1E5
S-71PU1E5 S-100PU1E5 S-125PU1E5 S-140PU1E5
S-50PY1E5
S-50PT1E5
S-60PT1E5
S-71PT1E5 S-100PT1E5 S-125PT1E5 S-140PT1E5
S-50PT2E5
S-60PT2E5
S-71PT2E5 S-100PT2E5 S-125PT2E5 S-140PT2E5
S-60PK1E5
S-71PK1E5
S-50PF1E5
S-60PF1E5
S-71PF1E5 S-100PF1E5 S-125PF1E5 S-140PF1E5
S-60PN1E5
S-71PN1E5 S-100PN1E5 S-125PN1E5 S-140PN1E5
60
71
U-60PE1E5
U-71PE1E5
U-71PE1E8
U-60PEY1E5
U-71PEY1E5 U-100PEY1E5 U-125PEY1E5
Order No. SBPAC1301005CE
Outdoor Unit
71
100
100
U-100PE1E5
U-125PE1E5
U-100PE1E8
U-125PE1E8
U-100PEY1E8 U-125PEY1E8
REFERENCE NO.
Order No. SM830211-11CE
125
140
125
140
U-140PE1E5
U-140PE1E8
U-140PEY1E8
SM830211-07

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic S-45PU1E5

  • Page 1 4-Way Cassette 60×60 Ceiling Wall Mounted Low Silhouette Ducted Ducted R410A Models Model No. Indoor Units Indoor Type Units Type 4-Way Cassette S-36PU1E5 S-45PU1E5 S-50PU1E5 S-60PU1E5 S-71PU1E5 S-100PU1E5 S-125PU1E5 S-140PU1E5 4-Way Cassette S-36PY1E5 S-45PY1E5 S-50PY1E5 – – – – –...
  • Page 2 When Transporting IMPORTANT! Please Read Before Starting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees This air conditioner must be installed by the sales dealer when lifting to reduce strain on your back. Sharp edges or installer.
  • Page 3 • Do not leak refrigerant while piping work for an installation or re-installation, and while repairing refrigeration parts. Handle liquid refrigerant carefully as it may cause frostbite. When Servicing • Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.
  • Page 4: Check Of Density Limit

    Check of Density Limit The standards for minimum room volume are as follows. (1) No partition (shaded portion) The room in which the air conditioner is to be installed requires a design that in the event of refrigerant gas leaking out, its density will not exceed a set limit. The refrigerant (R410A), which is used in the air conditioner, is safe, without the toxicity or combustibility of ammonia, and is not restricted by laws imposed to protect the ozone layer.
  • Page 5: Important Information Regarding The Refrigerant Used

    IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A value: 1975 GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information.
  • Page 6: Combination Of Indoor And Outdoor Units

    Combination of Indoor and Outdoor Units Single-phase S-36PU1E5 x2 S-45PU1E5 x3 S-50PU1E5 S-60PU1E5 S-71PU1E5 S-100PU1E5 S-125PU1E5 S-140PU1E5 U-71PE1E5 U-125PE1E5 U-50PE1E5 U-60PE1E5 U-71PE1E5 U-100PE1E5 U-125PE1E5 U-140PE1E5 S-36PU1E5 x3 S-50PU1E5 x2 S-60PU1E5 x2 S-71PU1E5 x2 U-100PE1E5 U-100PE1E5 U-125PE1E5 U-140PE1E5 S-36PU1E5 x4 S-50PU1E5 x3...
  • Page 7 Combination of Indoor and Outdoor Units 3-phase S-36PU1E5 x2 S-45PU1E5 x3 S-50PU1E5 x2 S-60PU1E5 x2 S-71PU1E5 S-100PU1E5 S-125PU1E5 S-140PU1E5 U-71PE1E8 U-125PE1E8 U-100PE1E8 U-125PE1E8 U-71PE1E8 U-100PE1E8 U-125PE1E8 U-140PE1E8 S-36PU1E5 x3 S-50PU1E5 x3 S-71PU1E5 x2 U-100PE1E8 U-140PE1E8 U-140PE1E8 S-36PU1E5 x4 U-125PE1E8 S-36PY1E5 x2...
  • Page 8 Combination of Indoor and Outdoor Units PEY1 Single-phase S-36PU1E5 x2 S-50PU1E5 x2 S-60PU1E5 S-71PU1E5 S-100PU1E5 S-125PU1E5 U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 U-71PEY1E5 U-100PEY1E5 P165 P166 P167 P169 P170 P171 S-60PU1E5 x2 U-125PEY1E5 P168 S-36PY1E5 x2 S-50PY1E5 x2 U-71PEY1E5 U-100PEY1E5 P178 P179 S-36PT1E5 x2 S-50PT1E5 x2 S-60PT1E5...
  • Page 9: Table Of Contents

    —— CONTENTS —— Section 1. SPECIFICATIONS....................1-1 1-1. Unit Specifications ........................1-2. Dimensional Data ........................ 1-241 1-3. Refrigerant Flow Diagram ....................1-255 1-4. Operating Range ......................... 1-258 1-5. Capacity Correction Graph According to Temperature Condition ........1-259 1-6. Noise Criterion Curves ......................
  • Page 10 Section 6. OUTDOOR UNIT MAINTENANCE REMOTE CONTROL ........6-1. Overview ..........................6-2. Functions..........................6-3. Normal Display Operations and Functions ................6-4. Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor Temperatures ..6-5. Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit Alarm History ....6-6.
  • Page 11: Dimensional Data

    1. SPECIFICATIONS 1-1. Unit Specifications....................1. 4-Way Cassette Type (U1) ....................... 2. 4-Way Cassette 60×60 Type (Y1) ....................1-28 3. Ceiling Type (T1) ..........................1-41 4. Ceiling Type (T2) ..........................1-67 5. Wall Mounted Type (K1) ........................1-93 6. Low Silhouette Ducted Type (F1) .....................
  • Page 12 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-36PU1E5×2 / U-71PE1E5 INDOOR MODEL S-36PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 13 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-36PU1E5×3 / U-100PE1E5 INDOOR MODEL S-36PU1E5×3 PANEL MODEL CZ-KPU2×3 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 14 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-36PU1E5×4 / U-125PE1E5 INDOOR MODEL S-36PU1E5×4 PANEL MODEL CZ-KPU2×4 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 15 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-45PU1E5×3 / U-125PE1E5 INDOOR MODEL S-45PU1E5×3 PANEL MODEL CZ-KPU2×3 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5...
  • Page 16 Single-Type 1-1. Unit Specifications 1. 4-Way Cassette Type S-50PU1E5 / U-50PE1E5 INDOOR MODEL S-50PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100 17100 17100 5100...
  • Page 17 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-50PU1E5×2 / U-100PE1E5 INDOOR MODEL S-50PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 18 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-50PU1E5×3 / U-140PE1E5 INDOOR MODEL S-50PU1E5×3 PANEL MODEL CZ-KPU2×3 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 19 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-60PU1E5 / U-60PE1E5 INDOOR MODEL S-60PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-60PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500...
  • Page 20 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-60PU1E5×2 / U-125PE1E5 INDOOR MODEL S-60PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 21 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-71PU1E5 / U-71PE1E5 INDOOR MODEL S-71PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 22: Unit Specifi Cations

    Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-71PU1E5×2 / U-140PE1E5 INDOOR MODEL S-71PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 23 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-100PU1E5 / U-100PE1E5 INDOOR MODEL S-100PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY...
  • Page 24 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-125PU1E5 / U-125PE1E5 INDOOR MODEL S-125PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY...
  • Page 25 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-140PU1E5 / U-140PE1E5 INDOOR MODEL S-140PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY...
  • Page 26 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-36PU1E5×2 / U-71PE1E8 INDOOR MODEL S-36PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 27 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-36PU1E5×3 / U-100PE1E8 INDOOR MODEL S-36PU1E5×3 PANEL MODEL CZ-KPU2×3 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 28 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-36PU1E5×4 / U-125PE1E8 INDOOR MODEL S-36PU1E5×4 PANEL MODEL CZ-KPU2×4 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 29 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-45PU1E5×3 / U-125PE1E8 INDOOR MODEL S-45PU1E5×3 PANEL MODEL CZ-KPU2×3 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5...
  • Page 30 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-50PU1E5×2 / U-100PE1E8 INDOOR MODEL S-50PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 31 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-50PU1E5×3 / U-140PE1E8 INDOOR MODEL S-50PU1E5×3 PANEL MODEL CZ-KPU2×3 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 32 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-60PU1E5×2 / U-125PE1E8 INDOOR MODEL S-60PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 33 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-71PU1E5 / U-71PE1E8 INDOOR MODEL S-71PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 34 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-71PU1E5×2 / U-140PE1E8 INDOOR MODEL S-71PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 35 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-100PU1E5 / U-100PE1E8 INDOOR MODEL S-100PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY...
  • Page 36 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-125PU1E5 / U-125PE1E8 INDOOR MODEL S-125PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY...
  • Page 37 Single-Type 1-1. Unit Specifi cations 1. 4-Way Cassette Type S-140PU1E5 / U-140PE1E8 INDOOR MODEL S-140PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY...
  • Page 38 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-36PY1E5×2 / U-71PE1E5 INDOOR MODEL S-36PY1E5×2 PANEL MODEL CZ-KPY2×2 OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h...
  • Page 39 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-36PY1E5×3 / U-100PE1E5 INDOOR MODEL S-36PY1E5×3 PANEL MODEL CZ-KPY2×3 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 40 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-36PY1E5×4 / U-125PE1E5 INDOOR MODEL S-36PY1E5×4 PANEL MODEL CZ-KPY2×4 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 41 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-45PY1E5×3 / U-125PE1E5 INDOOR MODEL S-45PY1E5×3 PANEL MODEL CZ-KPY2×3 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 42 Single-Type 1-1. Unit Specifications 2. 4-Way Cassette 60×60 Type S-50PY1E5 / U-50PE1E5 INDOOR MODEL S-50PY1E5 PANEL MODEL CZ-KPY2 OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100 17100 17100...
  • Page 43 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-50PY1E5×2 / U-100PE1E5 INDOOR MODEL S-50PY1E5×2 PANEL MODEL CZ-KPY2×2 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 44 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-50PY1E5×3 / U-140PE1E5 INDOOR MODEL S-50PY1E5×3 PANEL MODEL CZ-KPY2×3 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 45 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-36PY1E5×2 / U-71PE1E8 INDOOR MODEL S-36PY1E5×2 PANEL MODEL CZ-KPY2×2 OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h...
  • Page 46 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-36PY1E5×3 / U-100PE1E8 INDOOR MODEL S-36PY1E5×3 PANEL MODEL CZ-KPY2×3 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 47 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-36PY1E5×4 / U-125PE1E8 INDOOR MODEL S-36PY1E5×4 PANEL MODEL CZ-KPY2×4 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 48 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-45PY1E5×3 / U-125PE1E8 INDOOR MODEL S-45PY1E5×3 PANEL MODEL CZ-KPY2×3 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 49 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-50PY1E5×2 / U-100PE1E8 INDOOR MODEL S-50PY1E5×2 PANEL MODEL CZ-KPY2×2 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 50 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 2. 4-Way Cassette 60×60 Type S-50PY1E5×3 / U-140PE1E8 INDOOR MODEL S-50PY1E5×3 PANEL MODEL CZ-KPY2×3 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 51 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-36PT1E5×2 / U-71PE1E5 INDOOR MODEL S-36PT1E5×2 PANEL MODEL OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200...
  • Page 52 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-36PT1E5×3 / U-100PE1E5 INDOOR MODEL S-36PT1E5×3 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 53 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-36PT1E5×4 / U-125PE1E5 INDOOR MODEL S-36PT1E5×4 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 54 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-45PT1E5×3 / U-125PE1E5 INDOOR MODEL S-45PT1E5×3 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 55 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-50PT1E5 / U-50PE1E5 INDOOR MODEL S-50PT1E5 PANEL MODEL OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100 17100 17100 5100...
  • Page 56 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-50PT1E5×2 / U-100PE1E5 INDOOR MODEL S-50PT1E5×2 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 57 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-50PT1E5×3 / U-140PE1E5 INDOOR MODEL S-50PT1E5×3 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 58 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-60PT1E5 / U-60PE1E5 INDOOR MODEL S-60PT1E5 PANEL MODEL OUTDOOR MODEL U-60PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500 8500...
  • Page 59 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-60PT1E5×2 / U-125PE1E5 INDOOR MODEL S-60PT1E5×2 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 60 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-71PT1E5 / U-71PE1E5 INDOOR MODEL S-71PT1E5 PANEL MODEL OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 8500...
  • Page 61 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-71PT1E5×2 / U-140PE1E5 INDOOR MODEL S-71PT1E5×2 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 62 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-100PT1E5 / U-100PE1E5 INDOOR MODEL S-100PT1E5 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 63 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-125PT1E5 / U-125PE1E5 INDOOR MODEL S-125PT1E5 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 64 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-140PT1E5 / U-140PE1E5 INDOOR MODEL S-140PT1E5 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h...
  • Page 65 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-36PT1E5×2 / U-71PE1E8 INDOOR MODEL S-36PT1E5×2 PANEL MODEL OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200...
  • Page 66 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-36PT1E5×3 / U-100PE1E8 INDOOR MODEL S-36PT1E5×3 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 67 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-36PT1E5×4 / U-125PE1E8 INDOOR MODEL S-36PT1E5×4 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 68 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-45PT1E5×3 / U-125PE1E8 INDOOR MODEL S-45PT1E5×3 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 69 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-50PT1E5×2 / U-100PE1E8 INDOOR MODEL S-50PT1E5×2 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 70 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-50PT1E5×3 / U-140PE1E8 INDOOR MODEL S-50PT1E5×3 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 71 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-60PT1E5×2 / U-125PE1E8 INDOOR MODEL S-60PT1E5×2 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 72 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-71PT1E5 / U-71PE1E8 INDOOR MODEL S-71PT1E5 PANEL MODEL OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 10900...
  • Page 73 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 3. Ceiling Type S-71PT1E5×2 / U-140PE1E8 INDOOR MODEL S-71PT1E5×2 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 74 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-100PT1E5 / U-100PE1E8 INDOOR MODEL S-100PT1E5 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 75 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-125PT1E5 / U-125PE1E8 INDOOR MODEL S-125PT1E5 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 76 Single -Type 1-1. Unit Specifi cations 3. Ceiling Type S-140PT1E5 / U-140PE1E8 INDOOR MODEL S-140PT1E5 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h...
  • Page 77 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-36PT2E5×2 / U-71PE1E5 INDOOR MODEL S-36PT2E5×2 PANEL MODEL OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200...
  • Page 78 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-36PT2E5×3 / U-100PE1E5 INDOOR MODEL S-36PT2E5×3 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 15.5...
  • Page 79 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-36PT2E5×4 / U-125PE1E5 INDOOR MODEL S-36PT2E5×4 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 80 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-45PT2E5×3 / U-125PE1E5 INDOOR MODEL S-45PT2E5×3 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 81 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-50PT2E5 / U-50PE1E5 INDOOR MODEL S-50PT2E5 PANEL MODEL OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100 17100 17100 5100...
  • Page 82 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-50PT2E5×2 / U-100PE1E5 INDOOR MODEL S-50PT2E5×2 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 83 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-50PT2E5×3 / U-140PE1E5 INDOOR MODEL S-50PT2E5×3 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 84 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-60PT2E5 / U-60PE1E5 INDOOR MODEL S-60PT2E5 PANEL MODEL OUTDOOR MODEL U-60PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500 8500...
  • Page 85 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-60PT2E5×2 / U-125PE1E5 INDOOR MODEL S-60PT2E5×2 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 86 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-71PT2E5 / U-71PE1E5 INDOOR MODEL S-71PT2E5 PANEL MODEL OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 8500...
  • Page 87 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-71PT2E5×2 / U-140PE1E5 INDOOR MODEL S-71PT2E5×2 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.0...
  • Page 88 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-100PT2E5 / U-100PE1E5 INDOOR MODEL S-100PT2E5 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 89 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-125PT2E5 / U-125PE1E5 INDOOR MODEL S-125PT2E5 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 90 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-140PT2E5 / U-140PE1E5 INDOOR MODEL S-140PT2E5 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.0 CAPACITY BTU/h...
  • Page 91 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-36PT2E5×2 / U-71PE1E8 INDOOR MODEL S-36PT2E5×2 PANEL MODEL OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200...
  • Page 92 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-36PT2E5×3 / U-100PE1E8 INDOOR MODEL S-36PT2E5×3 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 93 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-36PT2E5×4 / U-125PE1E8 INDOOR MODEL S-36PT2E5×4 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 94 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-45PT2E5×3 / U-125PE1E8 INDOOR MODEL S-45PT2E5×3 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 95 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-50PT2E5×2 / U-100PE1E8 INDOOR MODEL S-50PT2E5×2 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 96 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-50PT2E5×3 / U-140PE1E8 INDOOR MODEL S-50PT2E5×3 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P3HPC2BM PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.0...
  • Page 97 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-60PT2E5×2 / U-125PE1E8 INDOOR MODEL S-60PT2E5×2 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 98 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-71PT2E5 / U-71PE1E8 INDOOR MODEL S-71PT2E5 PANEL MODEL OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 8500...
  • Page 99 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 4. Ceiling Type S-71PT2E5×2 / U-140PE1E8 INDOOR MODEL S-71PT2E5×2 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.0...
  • Page 100 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-100PT2E5 / U-100PE1E8 INDOOR MODEL S-100PT2E5 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 101 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-125PT2E5 / U-125PE1E8 INDOOR MODEL S-125PT2E5 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 102 Single -Type 1-1. Unit Specifi cations 4. Ceiling Type S-140PT2E5 / U-140PE1E8 INDOOR MODEL S-140PT2E5 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.0 CAPACITY BTU/h...
  • Page 103 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-36PK1E5×2 / U-71PE1E5 INDOOR MODEL S-36PK1E5×2 PANEL MODEL OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 104 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-36PK1E5×3 / U-100PE1E5 INDOOR MODEL S-36PK1E5×3 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 105 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-36PK1E5×4 / U-125PE1E5 INDOOR MODEL S-36PK1E5×4 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 106 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-45PK1E5×3 / U-125PE1E5 INDOOR MODEL S-45PK1E5×3 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 107 Single -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-50PK1E5 / U-50PE1E5 INDOOR MODEL S-50PK1E5 PANEL MODEL OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100 17100 17100...
  • Page 108 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-50PK1E5×2 / U-100PE1E5 INDOOR MODEL S-50PK1E5×2 PANEL MODEL OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 109 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-50PK1E5×3 / U-140PE1E5 INDOOR MODEL S-50PK1E5×3 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 110 Single -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-60PK1E5 / U-60PE1E5 INDOOR MODEL S-60PK1E5 PANEL MODEL OUTDOOR MODEL U-60PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500...
  • Page 111 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-60PK1E5×2 / U-125PE1E5 INDOOR MODEL S-60PK1E5×2 PANEL MODEL OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 112 Single -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-71PK1E5 / U-71PE1E5 INDOOR MODEL S-71PK1E5 PANEL MODEL OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 113 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-71PK1E5×2 / U-140PE1E5 INDOOR MODEL S-71PK1E5×2 PANEL MODEL OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 114 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-36PK1E5×2 / U-71PE1E8 INDOOR MODEL S-36PK1E5×2 PANEL MODEL OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 115 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-36PK1E5×3 / U-100PE1E8 INDOOR MODEL S-36PK1E5×3 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 116 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-36PK1E5×4 / U-125PE1E8 INDOOR MODEL S-36PK1E5×4 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 117 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-45PK1E5×3 / U-125PE1E8 INDOOR MODEL S-45PK1E5×3 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 118 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-50PK1E5×2 / U-100PE1E8 INDOOR MODEL S-50PK1E5×2 PANEL MODEL OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 119 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-50PK1E5×3 / U-140PE1E8 INDOOR MODEL S-50PK1E5×3 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 120 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-60PK1E5×2 / U-125PE1E8 INDOOR MODEL S-60PK1E5×2 PANEL MODEL OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 121 Single -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-71PK1E5 / U-71PE1E8 INDOOR MODEL S-71PK1E5 PANEL MODEL OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 122 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 5. Wall Mounted Type S-71PK1E5×2 / U-140PE1E8 INDOOR MODEL S-71PK1E5×2 PANEL MODEL OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 123 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-36PF1E5×2 / U-71PE1E5 INDOOR MODEL S-36PF1E5×2 OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 7.10 7.10 7.10 CAPACITY...
  • Page 124 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-36PF1E5×3 / U-100PE1E5 INDOOR MODEL S-36PF1E5×3 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 125 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-36PF1E5×4 / U-125PE1E5 INDOOR MODEL S-36PF1E5×4 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 126 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-45PF1E5×3 / U-125PE1E5 INDOOR MODEL S-45PF1E5×3 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 127 Single-Type 1-1. Unit Specifications 6. Low Silhouette Ducted Type S-50PF1E5 / U-50PE1E5 INDOOR MODEL S-50PF1E5 PANEL MODEL OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100 17100 17100 5100...
  • Page 128 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-50PF1E5×2 / U-100PE1E5 INDOOR MODEL S-50PF1E5×2 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 129 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-50PF1E5×3 / U-140PE1E5 INDOOR MODEL S-50PF1E5×3 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 130 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-60PF1E5 / U-60PE1E5 INDOOR MODEL S-60PF1E5 OUTDOOR MODEL U-60PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 6.00 6.00 6.00 CAPACITY BTU/h 20500 20500 20500...
  • Page 131 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-60PF1E5×2 / U-125PE1E5 INDOOR MODEL S-60PF1E5×2 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 132 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-71PF1E5 / U-71PE1E5 INDOOR MODEL S-71PF1E5 OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 7.10 7.10 7.10 CAPACITY BTU/h 24200 24200 24200...
  • Page 133 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-71PF1E5×2 / U-140PE1E5 INDOOR MODEL S-71PF1E5×2 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 134 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-100PF1E5 / U-100PE1E5 INDOOR MODEL S-100PF1E5 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h 34100 34100...
  • Page 135 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-125PF1E5 / U-125PE1E5 INDOOR MODEL S-125PF1E5 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h 42700 42700...
  • Page 136 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-140PF1E5 / U-140PE1E5 INDOOR MODEL S-140PF1E5 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h 47800 47800...
  • Page 137 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-36PF1E5×2 / U-71PE1E8 INDOOR MODEL S-36PF1E5×2 OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 7.10 7.10 7.10 CAPACITY...
  • Page 138 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-36PF1E5×3 / U-100PE1E8 INDOOR MODEL S-36PF1E5×3 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 139 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-36PF1E5×4 / U-125PE1E8 INDOOR MODEL S-36PF1E5×4 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 140 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-45PF1E5×3 / U-125PE1E8 INDOOR MODEL S-45PF1E5×3 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 141 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-50PF1E5×2 / U-100PE1E8 INDOOR MODEL S-50PF1E5×2 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5...
  • Page 142 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-50PF1E5×3 / U-140PE1E8 INDOOR MODEL S-50PF1E5×3 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 143 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-60PF1E5×2 / U-125PE1E8 INDOOR MODEL S-60PF1E5×2 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0...
  • Page 144 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-71PF1E5 / U-71PE1E8 INDOOR MODEL S-71PF1E5 OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 7.10 7.10 7.10 CAPACITY BTU/h 24200...
  • Page 145 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-71PF1E5×2 / U-140PE1E8 INDOOR MODEL S-71PF1E5×2 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5...
  • Page 146 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-100PF1E5 / U-100PE1E8 INDOOR MODEL S-100PF1E5 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 147 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-125PF1E5 / U-125PE1E8 INDOOR MODEL S-125PF1E5 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 148 Single -Type 1-1. Unit Specifi cations 6. Low Silhouette Ducted Type S-140PF1E5 / U-140PE1E8 INDOOR MODEL S-140PF1E5 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h...
  • Page 149 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-36PN1E5×2 / U-71PE1E5 INDOOR MODEL S-36PN1E5×2 OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 8500...
  • Page 150 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 7. Ducted Type S-36PN1E5×3 / U-100PE1E5 INDOOR MODEL S-36PN1E5×3 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 151 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-36PN1E5×4 / U-125PE1E5 INDOOR MODEL S-36PN1E5×4 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 152 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 7. Ducted Type S-45PN1E5×3 / U-125PE1E5 INDOOR MODEL S-45PN1E5×3 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 153 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-50PN1E5 / U-50PE1E5 INDOOR MODEL S-50PN1E5 PANEL MODEL OUTDOOR MODEL U-50PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 17100 17100 17100 5100...
  • Page 154 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-50PN1E5×2 / U-100PE1E5 INDOOR MODEL S-50PN1E5×2 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 155 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 7. Ducted Type S-50PN1E5×3 / U-140PE1E5 INDOOR MODEL S-50PN1E5×3 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h...
  • Page 156 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-60PN1E5 / U-60PE1E5 INDOOR MODEL S-60PN1E5 OUTDOOR MODEL U-60PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500 8500 24200 CURRENT...
  • Page 157 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-60PN1E5×2 / U-125PE1E5 INDOOR MODEL S-60PN1E5×2 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 158 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-71PN1E5 / U-71PE1E5 INDOOR MODEL S-71PN1E5 OUTDOOR MODEL U-71PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 8500 27300 CURRENT...
  • Page 159 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-71PN1E5×2 / U-140PE1E5 INDOOR MODEL S-71PN1E5×2 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h...
  • Page 160 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-100PN1E5 / U-100PE1E5 INDOOR MODEL S-100PN1E5 OUTDOOR MODEL U-100PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h 34100 34100 34100 11300...
  • Page 161 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-125PN1E5 / U-125PE1E5 INDOOR MODEL S-125PN1E5 OUTDOOR MODEL U-125PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h 42700 42700 42700 11300...
  • Page 162 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-140PN1E5 / U-140PE1E5 INDOOR MODEL S-140PN1E5 OUTDOOR MODEL U-140PE1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h 47800 47800 47800 11300...
  • Page 163 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-36PN1E5×2 / U-71PE1E8 INDOOR MODEL S-36PN1E5×2 OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 8500...
  • Page 164 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 7. Ducted Type S-36PN1E5×3 / U-100PE1E8 INDOOR MODEL S-36PN1E5×3 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 165 Simultaneous (Double-Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-36PN1E5×4 / U-125PE1E8 INDOOR MODEL S-36PN1E5×4 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1×3 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 166 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 7. Ducted Type S-45PN1E5×3 / U-125PE1E8 INDOOR MODEL S-45PN1E5×3 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 167 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-50PN1E5×2 / U-100PE1E8 INDOOR MODEL S-50PN1E5×2 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h...
  • Page 168 Simultaneous (Triple) -Type 1-1. Unit Specifi cations 7. Ducted Type S-50PN1E5×3 / U-140PE1E8 INDOOR MODEL S-50PN1E5×3 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P3HPC2 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h...
  • Page 169 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-60PN1E5×2 / U-125PE1E8 INDOOR MODEL S-60PN1E5×2 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h...
  • Page 170 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-71PN1E5 / U-71PE1E8 INDOOR MODEL S-71PN1E5 OUTDOOR MODEL U-71PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200 8500 27300 CURRENT...
  • Page 171 Simultaneous (Twin) -Type 1-1. Unit Specifi cations 7. Ducted Type S-71PN1E5×2 / U-140PE1E8 INDOOR MODEL S-71PN1E5×2 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h...
  • Page 172 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-100PN1E5 / U-100PE1E8 INDOOR MODEL S-100PN1E5 OUTDOOR MODEL U-100PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 12.5 CAPACITY BTU/h 34100 34100...
  • Page 173 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-125PN1E5 / U-125PE1E8 INDOOR MODEL S-125PN1E5 OUTDOOR MODEL U-125PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 14.0 CAPACITY BTU/h 42700 42700...
  • Page 174 Single -Type 1-1. Unit Specifi cations 7. Ducted Type S-140PN1E5 / U-140PE1E8 INDOOR MODEL S-140PN1E5 OUTDOOR MODEL U-140PE1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.5 CAPACITY BTU/h 47800 47800...
  • Page 175 Simultaneous (Twin) -Type 1-1. Unit Specifications PEY1 1. 4-Way Cassette Type S-36PU1E5×2 / U-71PEY1E5 INDOOR MODEL S-36PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 176 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-50PU1E5×2 / U-100PEY1E5 INDOOR MODEL S-50PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø...
  • Page 177 Single-Type 1-1. Unit Specifications PEY1 1. 4-Way Cassette Type S-60PU1E5 / U-60PEY1E5 INDOOR MODEL S-60PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-60PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500...
  • Page 178 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-60PU1E5×2 / U-125PEY1E5 INDOOR MODEL S-60PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø...
  • Page 179 Single-Type 1-1. Unit Specifications PEY1 1. 4-Way Cassette Type S-71PU1E5 / U-71PEY1E5 INDOOR MODEL S-71PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 180 Single -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-100PU1E5 / U-100PEY1E5 INDOOR MODEL S-100PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 181 Single -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-125PU1E5 / U-125PEY1E5 INDOOR MODEL S-125PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 182 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-50PU1E5×2 / U-100PEY1E8 INDOOR MODEL S-50PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø...
  • Page 183 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-60PU1E5×2 / U-125PEY1E8 INDOOR MODEL S-60PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 184 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-71PU1E5×2 / U-140PEY1E8 INDOOR MODEL S-71PU1E5×2 PANEL MODEL CZ-KPU2×2 OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø...
  • Page 185 Single -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-100PU1E5 / U-100PEY1E8 INDOOR MODEL S-100PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 186 Single -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-125PU1E5 / U-125PEY1E8 INDOOR MODEL S-125PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 187 Single -Type 1-1. Unit Specifi cations PEY1 1. 4-Way Cassette Type S-140PU1E5 / U-140PEY1E8 INDOOR MODEL S-140PU1E5 PANEL MODEL CZ-KPU2 OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 188 Simultaneous (Twin) -Type 1-1. Unit Specifications PEY1 2. 4-Way Cassette 60×60 Type S-36PY1E5×2 / U-71PEY1E5 INDOOR MODEL S-36PY1E5×2 PANEL MODEL CZ-KPY2×2 OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 189 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 2. 4-Way Cassette 60×60 Type S-50PY1E5×2 / U-100PEY1E5 INDOOR MODEL S-50PY1E5×2 PANEL MODEL CZ-KPY2×2 OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø...
  • Page 190 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 2. 4-Way Cassette 60×60 Type S-50PY1E5×2 / U-100PEY1E8 INDOOR MODEL S-50PY1E5×2 PANEL MODEL CZ-KPY2×2 OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø...
  • Page 191 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-36PT1E5×2 / U-71PEY1E5 INDOOR MODEL S-36PT1E5×2 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200...
  • Page 192 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-50PT1E5×2 / U-100PEY1E5 INDOOR MODEL S-50PT1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 193 Single-Type 1-1. Unit Specifications PEY1 3. Ceiling Type S-60PT1E5 / U-60PEY1E5 INDOOR MODEL S-60PT1E5 PANEL MODEL OUTDOOR MODEL U-60PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500 6800 23900...
  • Page 194 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-60PT1E5×2 / U-125PEY1E5 INDOOR MODEL S-60PT1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 195 Single -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-71PT1E5 / U-71PEY1E5 INDOOR MODEL S-71PT1E5 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 196 Single -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-100PT1E5 / U-100PEY1E5 INDOOR MODEL S-100PT1E5 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 197 Single -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-125PT1E5 / U-125PEY1E5 INDOOR MODEL S-125PT1E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 198 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-50PT1E5×2 / U-100PEY1E8 INDOOR MODEL S-50PT1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 199 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-60PT1E5×2 / U-125PEY1E8 INDOOR MODEL S-60PT1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 200 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-71PT1E5×2 / U-140PEY1E8 INDOOR MODEL S-71PT1E5×2 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 201 Single -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-100PT1E5 / U-100PEY1E8 INDOOR MODEL S-100PT1E5 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 202 Single -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-125PT1E5 / U-125PEY1E8 INDOOR MODEL S-125PT1E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 13.5 CAPACITY...
  • Page 203 Single -Type 1-1. Unit Specifi cations PEY1 3. Ceiling Type S-140PT1E5 / U-140PEY1E8 INDOOR MODEL S-140PT1E5 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 204 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-36PT2E5×2 / U-71PEY1E5 INDOOR MODEL S-36PT2E5×2 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 205 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-50PT2E5×2 / U-100PEY1E5 INDOOR MODEL S-50PT2E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 206 Single -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-60PT2E5 / U-60PEY1E5 INDOOR MODEL S-60PT2E5 PANEL MODEL OUTDOOR MODEL U-60PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500...
  • Page 207 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-60PT2E5×2 / U-125PEY1E5 INDOOR MODEL S-60PT2E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 208 Single -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-71PT2E5 / U-71PEY1E5 INDOOR MODEL S-71PT2E5 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 209 Single -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-100PT2E5 / U-100PEY1E5 INDOOR MODEL S-100PT2E5 PANEL MODEL OUTDOOR MODEL U100PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0 11.5 CAPACITY...
  • Page 210 Single -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-125PT2E5 / U-125PEY1E5 INDOOR MODEL S-125PT2E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5 13.5 CAPACITY...
  • Page 211 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-50PT2E5×2 / U-100PEY1E8 INDOOR MODEL S-50PT2E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 212 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-60PT2E5×2 / U-125PEY1E8 INDOOR MODEL S-60PT2E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 213 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-71PT2E5×2 / U-140PEY1E8 INDOOR MODEL S-71PT2E5×2 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 214 Single -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-100PT2E5 / U-100PEY1E8 INDOOR MODEL S-100PT2E5 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0 11.5 13.5...
  • Page 215 Single -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-125PT2E5 / U-125PEY1E8 INDOOR MODEL S-125PT2E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 13.5 CAPACITY...
  • Page 216 Single -Type 1-1. Unit Specifi cations PEY1 4. Ceiling Type S-140PT2E5 / U-140PEY1E8 INDOOR MODEL S-140PT2E5 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0 15.0 CAPACITY...
  • Page 217 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 5. Wall Mounted Type S-36PK1E5×2 / U-71PEY1E5 INDOOR MODEL S-36PK1E5×2 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 218 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 5. Wall Mounted Type S-50PK1E5×2 / U-100PEY1E5 INDOOR MODEL S-50PK1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 219 Single-Type 1-1. Unit Specifications PEY1 5. Wall Mounted Type S-60PK1E5 / U-60PEY1E5 INDOOR MODEL S-60PK1E5 PANEL MODEL OUTDOOR MODEL U-60PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500 6800...
  • Page 220 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 5. Wall Mounted Type S-60PK1E5×2 / U-125PEY1E5 INDOOR MODEL S-60PK1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 221 Single -Type 1-1. Unit Specifi cations PEY1 5. Wall Mounted Type S-71PK1E5 / U-71PEY1E5 INDOOR MODEL S-71PK1E5 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200...
  • Page 222 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 5. Wall Mounted Type S-50PK1E5×2 / U-100PEY1E8 INDOOR MODEL S-50PK1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 223 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 5. Wall Mounted Type S-60PK1E5×2 / U-125PEY1E8 INDOOR MODEL S-60PK1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 224 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 5. Wall Mounted Type S-71PK1E5×2 / U-140PEY1E8 INDOOR MODEL S-71PK1E5×2 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 225 Simultaneous (Twin) -Type 1-1. Unit Specifications PEY1 6. Low Silhouette Ducted Type S-36PF1E5×2 / U-71PEY1E5 INDOOR MODEL S-36PF1E5×2 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200...
  • Page 226 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-50PF1E5×2 / U-100PEY1E5 INDOOR MODEL S-50PF1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø...
  • Page 227 Single-Type 1-1. Unit Specifications PEY1 6. Low Silhouette Ducted Type S-60PF1E5 / U-60PEY1E5 INDOOR MODEL S-60PF1E5 PANEL MODEL OUTDOOR MODEL U-60PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500...
  • Page 228 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-60PF1E5×2 / U-125PEY1E5 INDOOR MODEL S-60PF1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø...
  • Page 229 Single-Type 1-1. Unit Specifications PEY1 6. Low Silhouette Ducted Type S-71PF1E5 / U-71PEY1E5 INDOOR MODEL S-71PF1E5 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 230 Single -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-100PF1E5 / U-100PEY1E5 INDOOR MODEL S-100PF1E5 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 231 Single -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-125PF1E5 / U-125PEY1E5 INDOOR MODEL S-125PF1E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 232 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-50PF1E5×2 / U-100PEY1E8 INDOOR MODEL S-50PF1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø...
  • Page 233 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-60PF1E5×2 / U-125PEY1E8 INDOOR MODEL S-60PF1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 234 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-71PF1E5×2 / U-140PEY1E8 INDOOR MODEL S-71PF1E5×2 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø...
  • Page 235 Single -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-100PF1E5 / U-100PEY1E8 INDOOR MODEL S-100PF1E5 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 236 Single -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-125PF1E5 / U-125PEY1E8 INDOOR MODEL S-125PF1E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 237 Single -Type 1-1. Unit Specifi cations PEY1 6. Low Silhouette Ducted Type S-140PF1E5 / U-140PEY1E8 INDOOR MODEL S-140PF1E5 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 238 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-36PN1E5×2 / U-71PEY1E5 INDOOR MODEL S-36PN1E5×2 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200...
  • Page 239 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-50PN1E5×2 / U-100PEY1E5 INDOOR MODEL S-50PN1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 240 Single-Type 1-1. Unit Specifications PEY1 7. Ducted Type S-60PN1E5 / U-60PEY1E5 INDOOR MODEL S-60PN1E5 PANEL MODEL OUTDOOR MODEL U-60PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 20500 20500 20500 6800 23900...
  • Page 241 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-60PN1E5×2 / U-125PEY1E5 INDOOR MODEL S-60PN1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5...
  • Page 242 Single -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-71PN1E5 / U-71PEY1E5 INDOOR MODEL S-71PN1E5 PANEL MODEL OUTDOOR MODEL U-71PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY CAPACITY BTU/h 24200 24200 24200...
  • Page 243 Single -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-100PN1E5 / U-100PEY1E5 INDOOR MODEL S-100PN1E5 PANEL MODEL OUTDOOR MODEL U-100PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 244 Single -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-125PN1E5 / U-125PEY1E5 INDOOR MODEL S-125PN1E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E5 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 1ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 245 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-50PN1E5×2 / U-100PEY1E8 INDOOR MODEL S-50PN1E5×2 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0...
  • Page 246 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-60PN1E5×2 / U-125PEY1E8 INDOOR MODEL S-60PN1E5×2 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5...
  • Page 247 Simultaneous (Twin) -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-71PN1E5×2 / U-140PEY1E8 INDOOR MODEL S-71PN1E5×2 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL CZ-P155BK1 PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0...
  • Page 248 Single -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-100PN1E5 / U-100PEY1E8 INDOOR MODEL S-100PN1E5 PANEL MODEL OUTDOOR MODEL U-100PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN14825 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 10.0 10.0 10.0...
  • Page 249 Single -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-125PN1E5 / U-125PEY1E8 INDOOR MODEL S-125PN1E5 PANEL MODEL OUTDOOR MODEL U-125PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 12.5 12.5 12.5 13.5 CAPACITY...
  • Page 250 Single -Type 1-1. Unit Specifi cations PEY1 7. Ducted Type S-140PN1E5 / U-140PEY1E8 INDOOR MODEL S-140PN1E5 PANEL MODEL OUTDOOR MODEL U-140PEY1E8 Branch pipe MODEL PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12012 ø, Hz 1ø 50Hz 3ø 50Hz POWER SUPPLY 14.0 14.0 14.0...
  • Page 251 1-2. Dimensional Data (A) Indoor Units: S-36PU1E5 / S-45PU1E5 / S-50PU1E5 / S-60PU1E5 / S-71PU1E5 860~910 unit: mm (Ceiling opening dimensions) (Suspension bolt pitch) Less than 35 Less than 35 Less than 300 View X Raise dimension of drain tube...
  • Page 252 1-2. Dimensional Data (A) Indoor Units: S-100PU1E5 / S-125PU1E5 / S-140PU1E5 860~910 unit: mm (Ceiling opening dimensions) (Suspension bolt pitch) Less than 35 Less than 35 Less than 300 View X The length of the suspension bolts should be selected so that there is a gap of 30 mm or more below the lower surface of the ceiling (18 mm or more below the lower surface of...
  • Page 253 1-2. Dimensional Data (A) Indoor Units: S-36PY1E5, S-45PY1E5, S-50PY1E5 1-243...
  • Page 254 1-2. Dimensional Data (A) Indoor Units: S-36PT1E5, S-45PT1E5, S-50PT1E5, S-60PT1E5 S-71PT1E5, S-100PT1E5, S-125PT1E5, S-140PT1E5 Length Type 36, 45, 50 Air intake 60, 71 1125 1180 100, 125, 140 1540 1595 Ceiling side 27.5 27.5 Air outlet Unit: mm (Suspension bolt pitch) (Liquid tubing •...
  • Page 255 1-2. Dimensional Data (A) Indoor Units: S-36PT2E5, S-45PT2E5, S-50PT2E5 unit :mm Detailed view of intaking Distance of each exposed bolt must be of equal length outside air duct connection port within 50mm. Suspension bolt Unit Ceiling surface Bracket (Suspension bolt pitch) Over Over discharge...
  • Page 256 1-2. Dimensional Data (A) Indoor Units: S-60PT2E5, S-71PT2E5 unit :mm Detailed view of intaking Distance of each exposed bolt must be of equal length outside air duct connection port within 50mm. Suspension bolt Unit Ceiling surface 1226 (Suspension bolt pitch) Bracket 1269 Over...
  • Page 257 1-2. Dimensional Data (A) Indoor Units: S-100PT2E5, S-125PT2E5, S-140PT2E5 unit :mm Detailed view of intaking Distance of each exposed bolt must be of equal length outside air duct connection port within 50mm. Suspension bolt Unit Ceiling surface 1541 Bracket (Suspension bolt pitch) 1584 Over Over...
  • Page 258: Front View

    1-2. Dimensional Data (A) Indoor Units: S-36PK1E5, S-45PK1E5, S-50PK1E5, S-60PK1E5 S-71PK1E5 unit: mm Refrigerant tubing (liquid tube) S36 - S50: ø6.35 (flared) S60 - S71: ø9.52 (flared) Refrigerant tubing (gas tube) S36 - S50: ø12.7 (flared) S60 - S71: ø15.88 (flared) FILTER SIZE Drain hose VP13 (outer dia.
  • Page 259 1-2. Dimensional Data (A) Indoor Units: S-36PF1E5, S-45PF1E5, S-50PF1E5, S-60PF1E5 S-71PF1E5, S-100PF1E5, S-125PF1E5, S-140PF1E5 Unit: mm Type 36, 45, 50 450 (Pitch 150 × 3) 60, 71 1,067 1,000 750 (Pitch 150 × 5) 100, 125, 140 1,467 1,400 1,050 (Pitch 150 × 7) 1,192 a) Refrigerant tubing joint (liquid tube) b) Refrigerant tubing joint (gas tube)
  • Page 260 1-2. Dimensional Data (A) Indoor Units: S-36PN1E5, S-45PN1E5, S-50PN1E5 POSITION OF SUSPENSION BOLT (unit:mm) TYPE S-36PN1E5 S-45PN1E5 S-50PN1E5 S-60PN1E5 1060 1000 S-71PN1E5 S-100PN1E5 1260 1200 S-125PN1E5 S-140PN1E5 NOTE NAME Q'TY Pipe connection (gas) O.D. Ø12.7 Flared Pipe connection (liquid) O.D. Ø6.35 Flared Drain pipe connection Female screw PT1"...
  • Page 261 1-2. Dimensional Data (A) Indoor Units: S-60PN1E5, S-71PN1E5 Q'TY NOTE NAME Pipe connection (gas) O.D. Ø15.88 Flared Pipe connection (liquid) O.D. Ø9.52 Flared Drain pipe connection Female screw PT1" Duct connection Hanger 845 (P65 x 13) 57.5 Control box Air Flow 28-Ø4.5 30-Ø4.5 780 (P65 x 12)
  • Page 262 1-2. Dimensional Data (B) Outdoor Unit: U-50PE1E5 U-60PEY1E5 / U-71PEY1E5 (97) Drain port Air intake Air intake Drain port Air discharge (161) Refrigerant tubing joint (liquid tube) Unit: mm (157) Flare connection ø6.35 mm (50) ø9.52 mm (60, 71) Refrigerant tubing joint (gas tube) Flare connection ø12.7 mm (50) ø15.88 mm (60, 71) 1-252...
  • Page 263 1-2. Dimensional Data (B) Outdoor Units: U-60PE1E5 / U-71PE1E5/ U-100PEY1E5/ U-125PEY1E5 U-71PE1E8 / U-100PEY1E8/ U-125PEY1E8 unit: mm Mounting hole (4-R6.5), anchor bolt: M10 Refrigerant piping (liquid pipe), flared connection (ø9.52) Refrigerant piping (gas pipe), flared connection (ø15.88) Electrical wiring port ( ø13) ø22) Electrical wiring port (...
  • Page 264 1-2. Dimensional Data (B) Outdoor Units: U-100PE1E5 / U-125PE1E5 / U-140PE1E5 U-100PE1E8 / U-125PE1E8 / U-140PE1E8 / U-140PEY1E8 unit: mm Mounting hole (4-R6.5), anchor bolt: M10 Refrigerant piping (liquid pipe), flared connection (ø9.52) Refrigerant piping (gas pipe), flared connection (ø15.88) Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27)
  • Page 265 1-3. Refrigerant Flow Diagram Outdoor Unit: U-50PE1E5 Indoor Unit: Accumulator Compressor Gas line service valve ø12.7 Flare connection High pressure switch Muffler Muffler Heat exchanger 4-way valve Heat exchanger Distributor Strainer Electronic ref. Liquid line control valve service valve ø6.35 Flare connection Strainer Cooling cycle...
  • Page 266 1-3. Refrigerant Flow Diagram Outdoor Units: U-60PE1E5 / U-71PE1E5 Indoor Unit U-71PE1E8 High pressure 4-way switch valve Muffler ø15.88 Outdoor-air Heat Temp Thermistor exchanger Suction Temp Heat exchanger Thermistor Temp Thermistor Heat exchanger Discharge Temp Distributor Thermistor Defrost Temp Thermistor Strainer Distributor ø9.52...
  • Page 267 1-3. Refrigerant Flow Diagram Outdoor Units: U-100PEY1E5 / U-100PEY1E8 : t i Indoor Unit: High pressure 4-way switch valve ø15.88 Outdoor-air Heat Temp Thermistor exchanger Suction Temp Heat exchanger Thermistor Temp Thermistor Discharge Temp Thermistor Heat exchanger Distributor Defrost Temp Thermistor Strainer Distributor...
  • Page 268 1-4. Operationg Range Type PE1 Temperature Indoor air intake temp. Outdoor air intake temp. Maximum 32°C DB / 25°C WB 46°C DB Cooling Minimum 18°C DB / 14°C WB -15°C DB Maximum 30°C DB / − WB 24°C DB/18°C WB Heating Minimum 16°C DB / −...
  • Page 269 1-5. Capacity Correction Graph According to Temperature Condition U-50PE1E5 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp. ( °C DB) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 24 °CDB 20 °CDB...
  • Page 270 1-5. Capacity Correction Graph According to Temperature Condition U-60PE1E5 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 16 °CDB 20 °CDB 22°CWB 19°CWB 24 °CDB...
  • Page 271 1-5. Capacity Correction Graph According to Temperature Condition U-71PE1E5 (For 50 Hz) / U-71PE1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 16 °CDB 20 °CDB 22°CWB...
  • Page 272 1-5. Capacity Correction Graph According to Temperature Condition U-100PE1E5 (For 50 Hz) / U-100PE1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 273 1-5. Capacity Correction Graph According to Temperature Condition U-125PE1E5 (For 50 Hz) / U-125PE1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 274 1-5. Capacity Correction Graph According to Temperature Condition U-140PE1E5 (For 50 Hz) / U-140PE1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 275 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-60PEY1E5 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp. ( °C DB) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) 24 °CDB 20 °CDB 16 °CDB...
  • Page 276 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-71PEY1E5 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) Indoor air intake temp. ( °C DB) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 24 °CDB 20 °CDB...
  • Page 277 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-100PEY1E5 (For 50 Hz) / U-100PEY1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 278 1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-125PEY1E5 (For 50 Hz) / U-125PEY1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB...
  • Page 279: Capacity Correction Graph According To Temperature Condition

    1-5. Capacity Correction Graph According to Temperature Condition PEY1 U-140PEY1E8 (For 50 Hz) Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity) 16 °CDB 20 °CDB 24 °CDB 22°CWB 19°CWB 16°CWB Indoor air intake temp ( °C WB) Indoor air intake temp ( °C DB) 22°CWB 19°CWB 16°CWB...
  • Page 280: Noise Criterion Curves

    1-6. Noise Criterion Curves (A) Indoor Units: 4 WAY Cassette Type High : S-36PU1E5 : S-45PU1E5 MODEL MODEL SOUND LEVEL : High 30 dB(A) SOUND LEVEL : High 31 dB(A) 27 dB(A) 27 dB(A) CONDITION : Under the unit 1.5m CONDITION : Under the unit 1.5m...
  • Page 281: Way Cassette 60×60 Type (Y1)

    1-6. Noise Criterion Curves (A) Indoor Units: 4 WAY Cassette Type High : S-71PU1E5 : S-100PU1E5 MODEL MODEL : High 37 dB(A) : High 44 dB(A) SOUND LEVEL SOUND LEVEL 28 dB(A) 32 dB(A) : Under the unit 1.5m CONDITION CONDITION : Under the unit 1.5m : 220-230-240V, 1 phase, 50Hz...
  • Page 282 1-6. Noise Criterion Curves (A) Indoor Units: 4 WAY Cassette 60×60 Type Both 50Hz / 60Hz Strong Weak MODEL : S-45PY1E5 MODEL : S-36PY1E5 SOUND LEVEL : High 36 dB(A) SOUND LEVEL : High 32 dB(A) 28 dB(A) 26 dB(A) CONDITION : 1.5 m directly below unit CONDITION...
  • Page 283: Ceiling Type (T1)

    1-6. Noise Criterion Curves (A) Indoor Units: Both 50Hz / 60Hz High Ceiling Type : S-36PT1E5 : S-45PT1E5 MODEL MODEL S-50PT1E5 : High 35 dB(A) : High 38 dB(A) SOUND LEVEL SOUND LEVEL 30 dB(A) 30 dB(A) CONDITION CONDITION : 1 m from front of outlet at height of 1 m : 1 m from front of outlet at height of 1 m : 220-230-240V, 1 phase, 50Hz : 220-230-240V, 1 phase, 50Hz...
  • Page 284: Ceiling Type (T2)

    1-6. Noise Criterion Curves (A) Indoor Units: Both 50Hz / 60Hz High Ceiling Type : S-36PT2E5 : S-45PT2E5 MODEL MODEL S-50PT2E5 High 36 dB(A) High 37 dB(A) SOUND LEVEL : SOUND LEVEL : 29 dB(A) 29 dB(A) CONDITION CONDITION : 1 m from front of outlet at height of 1 m : 1 m from front of outlet at height of 1 m : 220-230-240V, 1 phase, 50Hz : 220-230-240V, 1 phase, 50Hz...
  • Page 285 1-6. Noise Criterion Curves (A) Indoor Units: Both 50Hz / 60Hz High Ceiling Type : S-100PT2E5 : S-125PT2E5 MODEL MODEL High 42 dB(A) High 46 dB(A) SOUND LEVEL : SOUND LEVEL : 35 dB(A) 36 dB(A) CONDITION CONDITION : 1 m from front of outlet at height of 1 m : 1 m from front of outlet at height of 1 m : 220-230-240V, 1 phase, 50Hz : 220-230-240V, 1 phase, 50Hz...
  • Page 286: Wall Mounted Type (K1)

    1-6. Noise Criterion Curves (A) Indoor Units: Both 50Hz / 60Hz Wall Mounted Type Strong Weak MODEL : S-36PK1E5 MODEL : S-45PK1E5 SOUND LEVEL : STRONG 35 dB(A) SOUND LEVEL : STRONG 38 dB(A) High 31 dB(A) High 34 dB(A) 27 dB(A) 30 dB(A) CONDITION...
  • Page 287: Low Silhouette Ducted Type (F1)

    1-6. Noise Criterion Curves (A) Indoor Units High Low Silhouette Ducted Type : S-36PF1E5 : S-45PF1E5 MODEL MODEL 33 dB(A) SOUND LEVEL : High 33 dB(A) SOUND LEVEL : High 25 dB(A) 25 dB(A) CONDITION : Under the unit 1.5m CONDITION : Under the unit 1.5m : 220-230-240V, 1 phase, 50Hz...
  • Page 288 1-6. Noise Criterion Curves (A) Indoor Units High Low Silhouette Ducted Type : S-100PF1E5 : S-125PF1E5 MODEL MODEL 39 dB(A) SOUND LEVEL : High 38 dB(A) SOUND LEVEL : High 31 dB(A) 32 dB(A) CONDITION : Under the unit 1.5m CONDITION : Under the unit 1.5m : 220-230-240V, 1 phase, 50Hz...
  • Page 289 1-6. Noise Criterion Curves (A) Indoor Units High Ducted Type MODEL : S-36PN1E5 MODEL : S-45PN1E5 S-50PN1E5 SOUND LEVEL SOUND LEVEL : HIGH 40 dB(A) : HIGH 41 dB(A) 35 dB(A) 35 dB(A) CONDITION CONDITION : Under the unit 1.5m : Under the unit 1.5m SOURCE SOURCE...
  • Page 290: (B) Outdoor Units

    1-6. Noise Criterion Curves (B) Outdoor Unit MODEL : U-50PE1E5 MODEL : U-50PE1E5 : Cooling 46 dB(A) : Heating 50 dB(A) SOUND LEVEL SOUND LEVEL : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION SOURCE...
  • Page 291 1-6. Noise Criterion Curves (B) Outdoor Unit MODEL : U-60PE1E5 MODEL : U-60PE1E5 : Cooling 48 dB(A) : Heating 50 dB(A) SOUND LEVEL SOUND LEVEL : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION SOURCE...
  • Page 292 1-6. Noise Criterion Curves (B) Outdoor Unit : U-100PE1E5, U-100PE1E8 MODEL : U-100PE1E5, U-100PE1E8 MODEL : Cooling 52 dB(A) : Heating 52 dB(A) SOUND LEVEL SOUND LEVEL : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION SOURCE...
  • Page 293 1-6. Noise Criterion Curves (B) Outdoor Unit : U-140PE1E5, U-140PE1E8 MODEL : U-140PE1E5, U-140PE1E8 MODEL : Cooling 54 dB(A) : Heating 55 dB(A) SOUND LEVEL SOUND LEVEL : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION SOURCE...
  • Page 294 1-6. Noise Criterion Curves (B) Outdoor Unit : U-60PEY1E5 : U-60PEY1E5 MODEL MODEL : Cooling 46 dB(A) : Heating 50 dB(A) SOUND LEVEL SOUND LEVEL CONDITION : 1 m in front at height of 1.5 m CONDITION : 1 m in front at height of 1.5 m : 220-230-240V, 1 phase, 50Hz : 220-230-240V, 1 phase, 50Hz SOURCE...
  • Page 295 1-6. Noise Criterion Curves (B) Outdoor Unit MODEL : U-100PEY1E5, U-100PEY1E8 MODEL : U-100PEY1E5, U-100PEY1E8 : Cooling 54 dB(A) : Heating 54 dB(A) SOUND LEVEL SOUND LEVEL : 1 m in front at height of 1.5 m : 1 m in front at height of 1.5 m CONDITION CONDITION SOURCE...
  • Page 296 1-6. Noise Criterion Curves (B) Outdoor Unit : U-140PEY1E8 MODEL MODEL : U-140PEY1E8 SOUND LEVEL : Cooling 54 dB(A) : Heating 53 dB(A) SOUND LEVEL : 1 m in front at height of 1.5 m CONDITION : 1 m in front at height of 1.5 m CONDITION SOURCE : 380-400-415V, 3 phase, 50Hz...
  • Page 297: Indoor Fan Performance

    1-7. Indoor Fan Performance External Static Pressure Setting for AC Fan Motor Model To apply to following models S-36PN1E5 , S-45PN1E5 , S-50PN1E5 There are two tap connector located in indoor unit control box can be selected. The "blue connector" is standard tap ,use-as-is at shipment. For high static pressure duct ,switch Fan Motor connector to plug in boost tap "white connector"...
  • Page 298: Airflow Distance Chart

    1-8. Airflow Distance Chart 4-Way Cassette Type S-60PU1E5 / 71PU1E5 Heating : Distribution of wind velocity ) ° ° 0 1.5m/s 1.0m/s 0.5m/s 0.3m/s Horizontal air flow distance (m) Heating : Distribution of temperature ) ° ° 0 Horizontal air flow distance (m) Cooling : Distribution of wind velocity ) °...
  • Page 299 S-100PU1E5 / 125PU1E5 / 140PU1E5 Heating : Distribution of wind velocity ) ° ° 0 1.5m/s 1.0m/s 0.5m/s 0.3m/s Horizontal air flow distance (m) Heating : Distribution of temperature ) ° ° 0 Horizontal air flow distance (m) Cooling : Distribution of wind velocity ) °...
  • Page 300 Ceiling Type (T2 Type) S-36PT2E5 / 45PT2E5 / 50PT2E5 Heating : Distribution of wind velocity (Strong wind : Discharge angle approx.54 ) (Room temperature approx.20 1.5m/s 1.0m/s 0.5m/s 0.3m/s Horizontal air flow distance (m) Heating : Distribution of temperature (Strong wind : Discharge angle approx.54 ) (Room temperature approx.20 Horizontal air flow distance (m) Cooling : Distribution of wind velocity...
  • Page 301 S-60PT2E5 / 71PT2E5 Heating : Distribution of wind velocity (Strong wind : Discharge angle approx.54 ) (Room temperature approx.20 1.5m/s 1.0m/s 0.5m/s 0.3m/s Horizontal air flow distance (m) Heating : Distribution of temperature (Strong wind : Discharge angle approx.54 ) (Room temperature approx.20 Horizontal air flow distance (m) Cooling : Distribution of wind velocity...
  • Page 302 S-100PT2E5 / 125PT2E5 / 140PT2E5 Heating : Distribution of wind velocity (Strong wind : Discharge angle approx.54 ) (Room temperature approx.20 1.5m/s 1.0m/s 0.5m/s 0.3m/s Horizontal air flow distance (m) Heating : Distribution of temperature (Strong wind : Discharge angle approx.54 ) (Room temperature approx.20 Horizontal air flow distance (m) Cooling : Distribution of wind velocity...
  • Page 303: Intaking Fresh Air Of 4-Way Cassette Type

    1-9. Intaking Fresh Air of 4-Way cassette Type Precautions Regarding External Air Intake (1) Ventilation Load Ensure that the design of the air-conditioner takes air-conditioning loads into consideration when external air intake is involved. (2) Restrictions on External Air Intake Ensure that the design conforms to the restrictions on air intake volume stipulated in accordance with the model of the indoor unit and the intake method.
  • Page 304 • U1, Y1 Types When an External Air Intake Flange (ø100) is in Use With the External Air Intake Flange Attached External Air Intake Volume and Resistance and Operation Noise Characteristics within the Unit U1 Type Y1 Type Duct (ø100) for Connecting the External Air Intake Flange Operation Noise (External Air Intake Only)
  • Page 305: Electrical Wiring

    1-10. Electrical Wiring General Precautions on Wiring Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. Provide a power outlet to be used exclusively for each unit and a circuit breaker for overcurrent protection should be provided in the exclusive line.
  • Page 306 Wiring System Diagrams * 3-phase model connections Indoor unit (No. 1) Power supply Outdoor unit (3-phase) 220/230/240V ~50Hz INV unit Power supply Ground Remote 380/400/415V, 3 N~, 50Hz controller Ground Ground Ground Indoor unit * Single-phase model connections (No. 2) Power supply Ground 220/230/240V ~50Hz...
  • Page 307 CAUTION (1) When linking the outdoor units in a network, disconnect the terminal extended from the short plug from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) For a system without link (no wiring connection between outdoor units), do not remove the short plug. (2) Do not install the inter-unit control wiring in a way that forms a loop.
  • Page 308 How to connect wiring to the terminal For stranded wiring (1) Cut the wire end with cutting pliers, Stranded wire Special Screw then strip the insulation to expose washer the stranded wiring about 10 mm and Ring tightly twist the wire ends. (Fig. 1-1) pressure Ring pressure terminal...
  • Page 309 Wiring samples T1 type Y1 type Functional ground screw (External Electronic Expansion Valve Kit and Schedule Timer) Protective ground screw Remote Control Wiring Power Supply Inter-unit Control Wiring Use this screw when connecting the shield Use this screw when connecting the shield for the Inter-unit control wiring to ground.
  • Page 310: Installation Instructions

    1-11. Installation instructions U-50PE1E5, U-60PEY1E5, U-71PEYE5 ACCESSORIES SUPPLIED WITH OUTDOOR UNIT Part Name Figure Q’ty Remarks Part Name Figure Q’ty Remarks Operating Installation Included this A5-size Instructions Instructions instructions SELECTING THE INSTALLATION SITE AVOID: heat sources and exhaust fans, etc. Exhaust fan damp, humid or uneven locations.
  • Page 311 (3) Obstructions on the front side and above the unit (Left side, right side and rear side are opened). 50 cm 30 cm or more or more In case of multiple installations Air intake Air intake Provide a solid base (concrete block, 10 × 40 cm beams or equal), a minimum of 15 cm above ground level to reduce humidity and protect the unit against possible water damage and decreased service life.
  • Page 312 Precautions for Installation in Heavy Snow Areas The platform should be higher than the maximum snow depth +50 cm. The 2 anchoring feet of the outdoor unit should be used for the platform, and the platform should be installed beneath the air intake side of outdoor unit. The platform foundation must be firm and the unit must be secured with anchor bolts.
  • Page 313 Tubing Size (A) Single type Refrigerant tubing between the indoor and outdoor units should be kept as short as possible. The lengths of the refrigerant tubes between the indoor and outdoor units are limited by the elevation difference between the 2 units. During tubing work, try to make both the tubing length (L) and the difference in elevation (H1) as short as possible.
  • Page 314 Table 1-2 Tubing Data for Models (Single, Twin) U-60PEY1E5 Models U-50PE1E5 Tubing Data U-71PEY1E5 Liquid tube mm (in.) 6.35 (1/4) 9.52 (3/8) Tubing size outer diameter Gas tube mm (in.) 12.7 (1/2) 15.88 (5/8) Limit of tubing length 50 * Outdoor unit is placed higher Limit of elevation difference...
  • Page 315 CAUTION 1. This unit requires no additional refrigerant charge up to tubing length 20 m (50 type: 30 m). In case of more than 20 m (50 type: 30 m), additional refrigerant charge is required. 2. In case of multi type installation, indoor units should be installed within the same room. If multi type indoor units are installed in different rooms, temperature control may develop problems because thermostat operation must follow the thermostat condition of 1 indoor unit only (the main unit).
  • Page 316 HOW TO INSTALL THE OUTDOOR UNIT Installing the Outdoor Unit Use concrete or a similar material to make the base, and ensure good drainage. Ordinarily, ensure a base height of 5 cm or more. If a drain pipe is used, or for use in cold-weather regions, ensure a height of 15 cm or more at the feet on both sides of the unit.
  • Page 317 HOW TO PROCESS TUBING The liquid tubing side is connected by a flare nut, and the gas tubing side is connected by brazing. Connecting the Refrigerant Tubing Use of the Flaring Method Many of conventional split system air conditioners employ the flaring method to connect refrigerant tubes that run between indoor and outdoor units.
  • Page 318 Caution Before Connecting Tubes Tightly (1) Apply a sealing cap or water-proof tape to prevent dust or water from entering the tubes before they are used. (2) Be sure to apply refrigerant lubricant to the matching surfaces of the flare and union before connecting them together. This is effective for reducing gas leaks.
  • Page 319 For the flare nuts at tubing connections, be sure to use the flare nuts that were supplied with the unit, or else flare nuts for R410A (type 2). The refrigerant tubing that is used must be of the correct wall thickness as shown in the table below. Tightening torque Tube diameter Tube thickness...
  • Page 320 Insulating the Refrigerant Tubing Tubing Insulation Thermal insulation must be applied to all units tubing, Two tubes arranged together including distribution joint (purchased separately). Inter-unit Gas tube * For gas tubing, the insulation material must be heat control resistant to 120°C or above. For other tubing, it must be wiring Liquid tube heat resistant to 80°C or above.
  • Page 321 Taping the Tubes (1) At this time, the refrigerant tubes (and electrical wiring if local codes permit) should be taped together with armoring tape in 1 bundle. To prevent condensation from overflowing the drain pan, keep the drain hose separate from the refrigerant tubing.
  • Page 322 LEAK TEST, EVACUATION AND ADDITIONAL REFRIGERANT CHARGE Perform an air-tightness test for this package A/C. Check that there is no leakage from any of the connections. Air and moisture in the refrigerant system may have undesirable effects as indicated below. pressure in the system rises operating current rises cooling (or heating) efficiency drops...
  • Page 323 Leak Test (1) With the service valves on the outdoor unit closed, remove the 6.35 mm flare nut and its bonnet on the gas tube service valve. (Save for reuse.) (2) Attach a manifold valve (with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses.
  • Page 324 Charging Additional Refrigerant Charging additional refrigerant (calculated from the liquid tube length as shown in “Amount of additional refrigerant charge”) using the liquid tube service valve. Use a balance to measure the refrigerant accurately. If the additional refrigerant charge amount cannot be charged at once, charge the remaining refrigerant in liquid form by using the gas tube service valve with the system in Cooling mode at the time of test run.
  • Page 325: Electrical Wiring

    ELECTRICAL WIRING General Precautions on Wiring (1) Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. (2) Provide a power outlet to be used exclusively for each unit and a circuit breaker for overcurrent protection should be provided in the exclusive line.
  • Page 326: Outdoor Unit

    Wiring System Diagrams Indoor unit (No. 1) Outdoor unit (single-phase) Power supply INV unit 220/230/240 V ~ 50Hz Power supply 220/230/240 ~ 50/60 Hz Ground Remote controller Ground Ground Ground Indoor unit Ground (No. 2) Power supply 220/230/240 V ~ 50Hz Ground Outdoor Unit NOTE...
  • Page 327 CAUTION (1) When linking the outdoor units in a network, disconnect the terminal extended from the short plug from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) For a system without link (no wiring connection between outdoor units), do not remove the short plug. (2) Do not install the inter-unit control wiring in a way that forms a loop.
  • Page 328 How to connect wiring to the terminal Air Purging with a Vacuum Pump (for Test Run) Preparation Stranded wire (1) Cut the wire end with cutting pliers, then strip the insulation to expose the stranded wire about 10 mm and tightly twist the wire ends. Ring pressure terminal...
  • Page 329 TEST RUN Preparing for Test Run Before attempting to start the air conditioner, check the following: (1) All loose matter is removed from the cabinet especially steel filings, bits of wire, and clips. (2) The control wiring is correctly connected and all electrical connections are tight. (3) The protective spacers for the compressor used for transportation have been removed.
  • Page 330 U1, Y1, T1, F1, N1 Types Caution This unit may be used in a single-type refrigerant system where 1 outdoor unit is connected to 1 indoor unit, and also in a system where 1 outdoor unit is connected to multiple indoor units (maximum 2). * If multiple indoor units are used, also refer to section “System Control”.
  • Page 331 Items to Check Before the Test Run (1) Turn the remote power switch ON at least 12 hours in advance in order to energize the crankcase heater. (2) Fully open the closed valves on the liquid-tube and gastube sides. Test Run Using the Remote Controller (1) Press and hold the remote controller button for 4 seconds or longer.
  • Page 332 Table of Self-Diagnostic Functions and Corrections (U1, Y1, T1, F1, N1 Types) Cause Wired Indoor Control by remote unit Simultaneous-operation Correction main-sub controller receiver 1:1 connection (single type) Group connection multi system remote display lamp (flexible combination) controllers Remote controller is not Remote controller is not Same at left Same at left Connect the remote...
  • Page 333 System Control System address rotary switch (Set to “0” at the time of shipment.) System control refers to the link wiring connection Inter-unit control wiring Ground for control of simultaneous-operation multi Outdoor unit For a simultaneous-operation Leakage breaker systems, group control, multi system, a maximum of 2 indoor units can be connected and mainsub remote controller control.
  • Page 334 (Wiring procedure) Connect the remote controller to the indoor unit remote control wiring terminal board (1, 2). (Remote control wiring) (2) Connect the indoor units (U1, U2) and the outdoor units (1, 2). Connect the other outdoor units and indoor units (with different refrigerant systems) in the same way.
  • Page 335 Automatic address setting using the remote controller When the outdoor unit shown in “Basic wiring diagram 2” is used for group control of multiple units, use the remote controller to perform automatic address setting. (During automatic address setting, “SETTING” blinks on the remote controller display.) Press the remote controller timer time button and...
  • Page 336 Connecting 2 remote controllers Connecting 2 remote controllers to control a to control 1 indoor unit simultaneous-operation multi system Remote controller Remote controller Remote controller Remote controller (main) (main) (sub) (sub) Remote control Optional Optional Optional Optional communication wiring Remote control wiring Terminal board for remote control Terminal board for...
  • Page 337 K1 Type Caution This unit may be used in a single-type refrigerant system where 1 outdoor unit is connected to 1 indoor unit, and also in a system where 1 outdoor unit is connected to multiple indoor units (maximum 2). * If multiple indoor units are used, also refer to section “System Control”...
  • Page 338 Items to Check Before the Test Run (1) Turn the remote power switch ON at least 12 hours in advance in order to energize the crankcase heater. (2) Fully open the closed valves on the liquid tube and gas tube sides. Preparation for Test Run Switching the temperature sensor Temperature sensors are contained in the indoor unit and wireless remote controller.
  • Page 339 Test Run Indoor control unit switch Using the control unit (1) Change the indoor control unit switch from “ON” → “TEST”. (The outdoor unit will not operate for 3 minutes after the power is turned ON and after operation is stopped.) TEST (2) All the indicator lamps blink while the test run is in progress.
  • Page 340 Table of Self-Diagnostic Functions and Corrections (K1 Type) Wired Cause remote controller Indoor unit Correction Group connection display receiver lamp 1:1 connection (Single type) (Simultaneous multi system) (Field supply) Indoor operation switch is OFF. Same at left Set the indoor operation switch ON. Nothing is Nothing is Turn ON the indoor unit power.
  • Page 341 System Control System control refers to the link wiring connection for control of simultaneous-operation multi systems, group control, and mainsub remote controller control. Basic wiring diagram 1 Single type and simultaneous-operation multi system Simultaneous-operation multi system Up to 2 (Twin) indoor units can be connected to 1 outdoor unit for operation. (However, coordinate the outdoor unit capacity and the total capacity of the indoor units.) (It is not possible to connect individual remote controllers for independent operation.) Be careful to avoid miswiring when connecting...
  • Page 342 Basic wiring diagram 2 Group control (when a central control device is not used) A maximum of 8 indoor units can be connected to a single remote controller. Example: In a refrigerant system where 2 or 3 indoor units are connected to 1 outdoor unit, set the new system address (refrigerant system address) before turning ON the remote power switch.
  • Page 343 Setting the outdoor unit system addresses For basic wiring diagram 2 (Set the system addresses: 1, 2,...) System address System address Outdoor unit control PCB System address 10s digit 1s place (2P DIP switch) (Rotary switch) System address rotary switch Both OFF (Set to “0”...
  • Page 344 Indoor unit remote controller main-sub setting When multiple wall mounted indoor units are installed for group control in a simultaneous-operation multi system, set the control PCB at the No. 2 and following wall mounted units to “Sub remote control”. If a wired remote controller is used, set the wired remote controller to “Sub”. If 2 wireless remote controllers are used, set the wireless PCB (DIP switch) on the second remote controller to “Sub”.
  • Page 345 U1, T1, F1, N1 Types (for Link Wiring) Caution This unit may be used in a single-type refrigerant system where 1 outdoor unit is connected to 1 indoor unit, and also in a system where 1 outdoor unit is connected to multiple indoor units (maximum 2 < Twin >). This test run explanation describes primarily the procedure when using the wired remote controller.
  • Page 346 Test Run Procedure See section “Items to Check Before the Recheck the items to check before the test run. Test Run” for U1, T1, F1, N1 Types (for Link Wiring). See section “Basic wiring diagram” Check the combination (wiring) of indoor and outdoor units. for U1, T1, F1, N1 Types (for Link Wiring).
  • Page 347 Items to Check Before the Test Run (1) Turn the remote power switch ON at least 12 hours in advance in order to energize the crankcase heater. (2) Fully open the closed valves on the liquid tube and gas tube sides. Test Run Using the Remote Controller (1) Press and hold the remote controller button for 4 seconds or longer.
  • Page 348 Automatic Address Setting Basic wiring diagram Link wiring N OTE A terminal plug (black) is attached to each of the outdoor unit control PCBs. At only one outdoor unit, leave the terminal plug shortcircuit socket on the “Yes” side. At all the other outdoor units, change the socket (from “Yes” to “No”). A maximum of 8 indoor units can be connected to 1 remote controller for group control.
  • Page 349 Case 2 If the power cannot be turned ON separately for the indoor and outdoor units in each system: The compressors must be run in order to automatically set the indoor unit addresses. Therefore perform this step after completing the refrigerant tubing work. Be sure to use a jig for short-circuiting.
  • Page 350 Case 4 If the power cannot be turned ON separately for the indoor and outdoor units in each system: (The compressors must be run in order to automatically set the indoor unit addresses. Therefore perform this step after completing the refrigerant tubing work.) All-systems automatic address setting: Display item code “AA”.
  • Page 351 Checking indoor unit addresses Use the remote controller to check the addresses of the indoor units. Press and hold the button and button for 4 seconds or longer (simple settings mode, “ALL” appears on the remote controller). Then press the button and select the indoor address.
  • Page 352 K1 Type (for Link Wiring) Caution This unit may be used in a single-type refrigerant system where 1 outdoor unit is connected to 1 indoor unit, and also in a system where 1 outdoor unit is connected to multiple indoor units (maximum 2). If link wiring is used, set the outdoor unit system address to allow the combination of indoor and outdoor units to be identified.
  • Page 353 Test Run Procedure (See section “Items to Check Before Recheck the items to check before the test run. the Test Run” for K1 Type .) (See section “Basic wiring diagram” Check the combination (wiring) of indoor and outdoor units. for K1 Type (for Link Wiring).) Is system “single-type”? (1 indoor unit is connected to 1 outdoor unit)
  • Page 354 Table of Self-Diagnostic Functions and Corrections (K1 Type) Wired Cause remote Indoor unit Correction Group connection and simultaneous-operation controller receiver lamp display multi system Remote controller is not connected with indoor unit Connect the remote controller correctly. Nothing is Nothing is correctly.
  • Page 355 Automatic Address Setting Basic wiring diagram Link wiring N OTE A terminal plug (black) is attached to each of the outdoor unit control PCBs. At only 1 outdoor unit, leave the terminal plug short-circuit socket on the “Yes” side. At all the other outdoor units, change the socket (from “Yes” to “No”). A maximum of 8 indoor units can be connected to 1 remote controller for group control.
  • Page 356 System address System address System address 10s digit 1s place (2P DIP switch) (Rotary switch) Both OFF “0” setting 0 Automatic address (Setting at shipment = “0”) Both OFF “1” setting 1 (If outdoor unit is No. 1) Both OFF “2”...
  • Page 357 Case 2 If the power cannot be turned ON separately for the indoor and outdoor units in each system: The compressors must be run in order to automatically set the indoor unit addresses. Therefore perform this step after completing the refrigerant tubing work. Be sure to use a jig for short-circuiting.
  • Page 358 Remote controller setting mode To set the remote controller main/sub setting or change the sensor, follow the steps below. (1) Press both buttons on the remote controller for more than 4 seconds together. (2) Select CODE No. with ) buttons. (3) Change DATA with (TIMER) buttons.
  • Page 359 Y1 Type (for Link Wiring) Caution This unit may be used in a single-type refrigerant system where 1 outdoor unit is connected to 1 indoor unit, and also in a system where 1 outdoor unit is connected to multiple indoor units (maximum 2 < Twin >). This test run explanation describes primarily the procedure when using the wired remote controller.
  • Page 360 Test Run Procedure (See section “Items to Check Before the Recheck the items to check before the test run. Test Run” for Y1 Type (for Link Wiring).) See section “Basic wiring diagram” Check the combination (wiring) of indoor and outdoor units. for Y1 Type (for Link Wiring).
  • Page 361 Items to Check Before the Test Run (1) Turn the remote power switch ON at least 12 hours in advance in order to energize the crankcase heater. (2) Fully open the closed valves on the liquid-tube and gas-tube sides. Test Run Using the Remote Controller (1) Press and hold the remote controller button for 4 seconds or longer.
  • Page 362 Automatic Address Setting Basic wiring diagram Link wiring N OTE A terminal plug (black) is attached to each of the outdoor unit control PCBs. At only one outdoor unit, leave the terminal plug short-circuit socket on the “Yes” side. At all the other outdoor units, change the socket (from “Yes” to “No”). A maximum of 8 indoor units can be connected to 1 remote controller for group control.
  • Page 363 Case 2 If the power cannot be turned ON separately for the indoor and outdoor units in each system: The compressors must be run in order to automatically set the indoor unit addresses. Therefore perform this step after completing the refrigerant tubing work. Be sure to use a jig for short-circuiting.
  • Page 364 Case 4 If the power cannot be turned ON separately for the indoor and outdoor units in each system: (The compressors must be run in order to automatically set the indoor unit addresses. Therefore perform this step after completing the refrigerant tubing work.) All-systems automatic address setting: Display item code “AA”.
  • Page 365 Checking indoor unit addresses Use the remote controller to check the addresses of the indoor units. Press and hold the button and button for 4 seconds or longer (simple settings mode, “ALL” appears on the remote controller). Then press the button and select the indoor address.
  • Page 366 Caution for Pump Down Pump down means refrigerant gas in the system is returned to the outdoor unit. Pump down is used when the unit is to be moved, or before servicing the refrigerant circuit. CAUTION This outdoor unit cannot collect more than the rated refrigerant amount as shown by the nameplate on the back.
  • Page 367: U-60Pe1E5 ~ U-140Pe1E5, U-71Pe1E8 ~ U-140Pe1E8

    U-60PE1E5 ~ U-140PE1E5, U-71PE1E8 ~ U-140PE1E8 U-100PEY1E5, U-125PEY1E5, U-100PEY1E8, U-125PEY1E8, U-140PEY1E8 ACCESSORIES SUPPLIED WITH OUTDOOR UNIT The following parts are supplied as accessories with each outdoor unit. Check that all accessory parts are present before installing the outdoor unit. Part name Q’ty Diagram Application Part name...
  • Page 368 SELECTING THE LOCATION FOR INSTALLATION SERVICE When installing multiple units, allow enough space in between the units and the side of the building. (A) If there are obstacles at the intake If the upper part is open (unit: mm) For separate installation location •...
  • Page 369 (B) If there are obstacles at the discharge If the upper part is open (unit: mm) For separate installation location For multiple units (more than 2 units) If there are obstacles above the unit (unit: mm) For separate installation location For multiple units (more than 2 units) If there are obstacles on both the intake and discharge If there is an obstacle that is higher than the unit on the intake side.
  • Page 370 If there is an obstacle that is higher than the unit on the discharge side. Pattern 2 (There is no limit to the height of theobstacle above the discharge.) If the upper part is open (unit: mm) For separate installation location For multiple units (more than 2 units) If there are obstacles above the unit (unit: mm)
  • Page 371 TRANSPORT AND INSTALL THE OUTDOOR UNIT Transporting 1. Transport the outdoor unit in its original packaging as close as possible to the installation location. 2. In the event that the unit needs to be lifted or suspended, use a rope or belt and use cloth or wood as padding to avoid damaging the unit.
  • Page 372 Precautions when operating the 3-way valve for piping installation Do not open the 3-way valve until the piping installation is completed. Valve shaft • It is closed during shipment. Service port • During installation the side panel may warp if only the flare nut is Valve cap loosened and tightened with a torque wrench.
  • Page 373 Precautions for flare nut installation Dimensions when adding flare nuts and the tightening torque (unit: mm) Piping size Tightening torque Flare section dimensions A Flare configuration 14.2N•m ~ 17.2N•m 8.7 ~ 9.1 ø 6.35 {1.4kgf•m ~ 1.7kgf•m} 32.7N•m ~ 39.9N•m 12.8 ~ 13.2 ø...
  • Page 374 Charging with refrigerant For the type PE1 At the time of shipment from the factory, this unit is charged with enough refrigerant for an equivalent pipe length of 30m. If the equivalent pipe length used will be 30m or less, no additional charging will be necessary. If the equivalent pipe length will be between 30 and 50 / 75m, charge with additional refrigerant according to the equivalent length given in the table below.
  • Page 375 ELECTRICAL WIRING This air conditioner must be installed in accordance with national wiring regulations. Cables connected to outdoor unit must be approved polychloroprene sheathed type 60245 IEC 57 or H05RN-F/H07RN-F or heavier. The units must be connected to the supply cables for fixed wiring by qualified technician. Circuit breaker must be incorporated in the fixed wiring in accordance with the national wiring regulations.
  • Page 376 OUTDOOR UNIT/3-PHASE MODEL OUTDOOR UNIT/SINGLE-PHASE MODEL Power supply (220/230/240V~) Power supply (380/400/415V 3N~) Power supply (220/230/240V~) Power supply (220/230/240V~) Circuit breaker Circuit breaker Circuit breaker Circuit breaker Switch Switch Switch Switch Earth Earth Earth Earth Indoor unit Outdoor unit Indoor unit Outdoor unit Wired remote controller Wired remote controller...
  • Page 377 COMBINATION OF INDOOR UNIT CONNECTION Twin, Triple and Double Twin Type Connections for PE1 Type Two, three or four indoor units can be operated simultaneously with a single remote controller. Note that individual operation is not possible. Master unit and slave unit can be set automatically in twin and triple system. No address setting is necessary.
  • Page 378 Piping Connections For PE1 Type The following table shows the pipe diameter. (Branch pipe kit should be used) (unit: mm) Indoor unit combination Outdoor unit main pipe Branch pipe diameter diameter (mm) S-36 S-45 S-50 S-60 S-71 Liquid side ø6.35 ø6.35 ø6.35 ø9.52...
  • Page 379 (TWIN type) Indoor unit Indoor unit Branch pipe Main pipe (TRIPLE type) Indoor unit Indoor unit Indoor unit Branch pipe Main pipe (DOUBLE TWIN type) Indoor unit Indoor unit Indoor unit Indoor unit Pipe branch 2 Pipe branch 2 Pipe branch 1 Main pipe •...
  • Page 380 Refrigerant charging For PE1 Type For the twin connection, the amount of refrigerant required for pipe length 30m has been included in this unit at the factory while that required for pipe length 20m has been included for the triple/double-twin connections. No additional charge is required for the first 30m pipe length in the case of the twin connection and for the first 20m in the case of the triple/double-twin connections.
  • Page 381 PRECAUTIONS REGARDING TEST RUN Check Before Test Run Content check Power supply cable Is the wire set up and connected as described in the instructions? Indoor/outdoor connection wire Check for any phase sequence. Earth wire Are the wire connection’s screws loose? Is the open and close device / leakage breaker installed? Is the power supply cable’s thickness and length appropriately measured as described in the instructions?
  • Page 382 Outdoor main PCB CHK pin RUN pin MODE pin *MODE pin: factory setting is cooling operation mode. CHECKS AFTER INSTALLATION HAVE COMPLETED Check the following items after completing installation. Is there a short circuit with the intake air flow? Is the insulation secure? (Refrigerant piping) Are there any errors with the wiring? Are the terminal screws loose? Tightening torque (Unit: N •...
  • Page 383 Optional Distribution Joint Kits CZ-P155BK1 Prior to undertaking the installation work, read carefully through the “Installation Instructions” for the air conditioner and this “Installation Instructions”. This line branch pipe is used for the R410A refrigerant. 1. Details of parts supplied Unit : mm (in.) 1 Liquid side branch pipe (inner diameter) 2 Gas side branch pipe (inner diameter)
  • Page 384 2-1 Installation Instructions Output (1) To next branch pipe or indoor unit Output (2) Refrigerant pipe Refrigerant pipe To the outdoor unit or Gas side / Liquid side next branch pipe Input branch pipe If the size of the selected refrigerant pipe and the size of the branch pipe differ, cut the connecting section with pipe cutters per the illustration at right.
  • Page 385 CZ-P3HPC2 Unit : mm CZ-P3HPC2 (for simultaneous Triple) Liquid distribution joint for liquid tube Gas distribution joint for gas tube Dowel pin position BCUP-3 (3 locations) ø12.7 ø25.4 Liquid-tube side tube connector Gas-tube side tube connector Gas-tube side tube connector ø19.05 ø28.58 ø19.05...
  • Page 386 Installing Distribution Joint Kit (for Triple) (CZ-P3HPC2) Only the distribution joints are horizontal with Check the system combination before installing the respect to the ground. The collective tubes are vertical with respect to the ground. distribution joints. Three indoor units must be installed within the The collective tube and distribution same room.
  • Page 387: Indoor Unit

    1. SELECTING THE INSTALLATION SITE 4-Way Cassette Type 4-Way Cassette Type (U1) Indoor Unit AVOID: areas where leakage of flammable gas may be expected. places where large amounts of oil mist exist. direct sunlight. locations near heat sources which may affect the performance of the unit.
  • Page 388 HOW TO INSTALL THE INDOOR UNIT 4-Way Cassette Type (U1 Type) Note: For DC Fan Tap Change Procedure for 4-Way Cassette, see page 1-339. Preparation for Suspending Hole-in-anchor This unit uses a drain pump. Use a carpenter’s level to check Hole-in-plug Insert Concrete...
  • Page 389 Placing the Unit Inside the Ceiling This unit is equipped with the drain pump. Check a tape measure or carpenter’s level. Ceiling Before installing the ceiling panel, complete the work of conditioner drain pipe and refrigerant pipe installation. (1) When placing the unit inside the ceiling, determine the pitch of the suspension bolts using the supplied full-scale Paper model for installation...
  • Page 390 Installing the Drain Pipe Before Performing the Installation Drain Piping (1) Limitations of Raising the Drain Pipe Connection 300 mm or less (as short as possible) CAUTION Indoor unit A : 850 mm or lower Ceiling surface The drain pipe can be raised to a maximum height of B : 670 mm or lower 850 mm from the bottom surface of the ceiling.
  • Page 391 Installing the Drain Pipe CAUTION Do not apply force to the drain port when connecting the 3) Move the hose band so that the center position of the drain pipe. Install and fix it near the indoor unit as close hose band can be placed approx.
  • Page 392 Checking the Drainage Be careful since the fan will start Drainage check CAUTION when you short the pin on the indoor control board. After wiring and drain piping are completed, use the following procedure to check that the water will drain smoothly. For this, prepare a bucket and wiping cloth to catch and wipe up Over 100 mm spilled water.
  • Page 393 Important Note for Wiring 4-Way Cassette Type Power supply inlet (1) The power supply inlet is located at the lower area of the refrigerant tubing side of the unit. The electrical component box is located at the air intake of the bottom of the unit.
  • Page 394 How to Install the Ceiling Panel (3) Installing the ceiling panel The power must be turned ON in order to change the (1) Removing the air-intake grille flap angle. (Do not attempt to move the flap by hand. 1) Remove the 2 screws on the latch of the air-intake Doing so may damage the flap.) grille.
  • Page 395 (5) How to Attach the Corner & Air-Intake Grille A. Attaching the corner cover CAUTION 1) Check that the safety cord from the corner cover is fastened to the ceiling panel pin, as shown in the figure If the screws are not sufficiently tightened, trouble below.
  • Page 396 Others 2) When setting with the Wired Remote Controller (1) Checking After Installation <Procedure> 1) Check that there are no gaps between the unit and Stop the system before performing these steps. the ceiling panel, or between the ceiling panel and the Press and hold the buttons ceiling surface.
  • Page 397 (4) Setting the Flap Separately (When setting the CZ-RTC2) Press the timer time buttons to select the 1) The 4-air outlet flap can be adjusted separately during desired setting data. operation. When not adjusted separately, all flaps Flap position operate in the same manner. Air discharge port Flap...
  • Page 398 (4-Way Cassette) Part Name Figure Q’ty Remarks Full-scale Printed on installation container box diagram For suspension Washer bolts For full-scale Screw installation diagram For gas and liquid (White) Insulating tape tube flare nuts Flare insulator For liquid tube Flare insulator For gas tube Drain hose For securing drain...
  • Page 399: Selecting The Installation Site 4-Way Cassette Type (U1)

    2. SELECTING THE INSTALLATION SITE HOW TO INSTALL THE INDOOR UNIT 4-Way Cassette 60×60 Type (Y1) 4-Way Cassette 60 × 60 Type Indoor Unit (Y1 Type) AVOID: Preparation for Ceiling Suspension areas where leakage of flammable gas may be expected. This unit uses a drain pump.
  • Page 400 Placing the Unit Inside the Ceiling Twist tie (4 ties, supplied) (1) When placing the unit inside the ceiling, determine the Hard PVC pipe Drain hose Position to (equivalent to pitch of the suspension bolts using the supplied full-scale Drain port insulation fasten hose O.D.
  • Page 401 (4-Way Cassette 60 × 60) 300 mm or less Part Name Figure Q'ty Remarks 850 mm or less 0 - 45° For temporarily Washer suspending indoor unit from ceiling * Length of supplied drain hose = 140 mm Fig. 2-8 Do not use natural drainage.
  • Page 402: How To Install The Ceiling Panel

    HOW TO INSTALL THE CEILING PANEL Before Installing the Ceiling Panel (1) Remove the air-intake grille and air filter from the ceiling panel. 4-Way Cassette 60 × 60 Type (Y1 Type) a) Remove the 2 screws on the latch of the air-intake Checking the unit position grille.
  • Page 403 The ceiling panel must be installed in the correct direction Wiring the Ceiling Panel relative to the unit. Align the REF. PIPE and DRAIN marks (1) Open the cover of the electrical component box. on the ceiling panel corner with the correct positions on the (2) Connect the 7P wiring connector (red) from the ceiling unit.
  • Page 404 Adjusting the Auto Flap Hole for ceiling The air-direction louver on the ceiling panel outlet can be panel hook adjusted as follows. Adjust the louver to the desired angle using the remote controller. The louver also has an automatic air-sweeping mechanism.
  • Page 405: Selecting The Installation Site Ceiling Type (T1)

    3. SELECTING THE INSTALLATION SITE Ceiling Ceiling Type (T1) Ceiling Indoor Unit AVOID: areas where leakage of flammable gas may be expected. Wall places where large amounts of oil mist exist. direct sunlight. Font view locations near heat sources which may affect the performance of the unit.
  • Page 406 HOW TO INSTALL THE INDOOR UNIT Ceiling Type (T1 Type) Air intake Required Minimum Space for Installation and Service Ceiling side (1) Dimensions of suspension bolt pitch and unit Length Type 36, 45, 50 27.5 27.5 (Suspension bolt pitch) 60, 71 1125 1180 Unit: mm...
  • Page 407 (4) Wall and ceiling side opening position WARNING Figure shows view from front. It is important that you use extreme care in supporting the indoor unit from the ceiling. Ensure that the ceiling is strong enough to support the weight of the unit. Before Ceiling hanging the ceiling unit, test the strength of each attached suspension bolt.
  • Page 408 Suspension bolt PVC pipe (field supply) (field supply) INSIDE OUTSIDE Washer Wall (field supply) PVC pipe Unit Slight Washer (supplied) angle Double nut (field supply) Cut at slight angle Fig. 3-12 Fig. 3-17 Duct for Fresh Air There is a duct connection port (knock-out hole) at the right-rear of the top panel of the indoor unit for drawing in fresh air.
  • Page 409 (Ceiling) Part Name Figure Q’ty Remarks For temporarily Special suspending indoor unit washer from ceiling Drain For drain hose joint insulator For gas and liquid tube Flare insulator sets joints Insulating For gas and liquid flare White tape joints (heat- resisting) For flare and drain Vinyl clamp...
  • Page 410: Selecting The Installation Site Ceiling Type (T2)

    4. SELECTING THE INSTALLATION SITE Ceiling Ceiling Type (T2) Indoor Unit Ceiling AVOID: areas where leakage of flammable gas may be expected. Wall places where large amounts of oil mist exist. direct sunlight. locations near heat sources which may affect the Minimum 25 cm Minimum 25 cm performance of the unit.
  • Page 411 Unit: mm HOW TO INSTALL THE INDOOR UNIT Ceiling Type (T2 Type) 4-1. Required Minimum Space for Installation and Service Air intake (1) Dimensions of suspension bolt pitch and unit Length Type 36, 45, 50 60, 71 1226 1275 100, 125, 140 1541 1590 Unit: mm...
  • Page 412 4-2. Preparation Before Installation (4) Remove the center bracket. When wiring, remove the center bracket if necessary. (1) Remove the bracket (for suspending the indoor unit). When wiring is completed, reinstall the center bracket in its Loose the M8 suspension bolts. original position.
  • Page 413 b) Suspend the indoor unit to the bracket. WARNING Tighten the M8 suspension bolts and fix the indoor unit in place. (Fig. 4-17) It is important that you use extreme care in supporting the indoor unit from the ceiling. Ensure that the ceiling is strong enough to support the weight of the unit.
  • Page 414 4-5. Shaping the Tubing Never allow water traps to occur in the course of the piping. Insulate any piping inside the room to prevent dripping. The positions of the refrigerant tubing connections are After the drain piping, pour an appropriate amount of water shown in the figure below.
  • Page 415 4-7. Final Procedure ( Ceiling ) Reinstall the removed part to be placed in its original position. Part Name Figure Q’ty Remarks (See the section “4-2. Preparation Before Installation”.) For temporarily suspending Special Then install the accessory supplied side covers (L/R) on both indoor unit from ceiling washer sides of the indoor unit.
  • Page 416: Selecting The Installation Site Wall Mounted Type (K1)

    5. SELECTING THE INSTALLATION SITE Wall Mounted Wall Mounted Type (K1) Indoor Unit AVOID: min. 7.5 cm min. min. areas where leakage of flammable gas may be expected. 5 cm 5 cm places where large amounts of oil mist exist. direct sunlight.
  • Page 417 HOW TO INSTALL THE INDOOR UNIT Wall Mounted Type (K1 Type) Remove the Rear Panel from the Unit (1) Remove and discard the set screw on the rear panel. (Fig. 5-1) (2) Press the 2 marks on the frame cover and disengage the stationary tabs from the frame.
  • Page 418 (4) Using a sabre saw, key hole saw or hole-cutting drill N OT E attachment, cut a hole in the wall. See Table 5-1 and Hole should be made at a slight downward slant to the outdoor Fig. 5-7. side. Indoor Outdoor Table 5-1...
  • Page 419 Removing and Installing the Grille Front panel Basically, these models can be installed and wired without removing the grille. If access to any internal part is needed, follow the steps as given below. How to remove the grille (1) Open the front panel until it is nearly horizontal, grasp the sections near the front panel arms on both sides, and then remove the panel by pushing the arms towards the outside while pulling the panel towards you.
  • Page 420 Shape the Indoor Side Tubing (1) Arrangement of tubing by direction a) Right or left tubing Cut out the corner of the right/left frame with a hacksaw or the like. (Figs. 5-19 and 5-20) Grille b) Right-rear or left-rear tubing In this case, the corner of the frame need not be cut.
  • Page 421 Mounting (1) To install the indoor unit, mount the indoor unit onto the 3 tabs on the upper part of the rear plate. (2) Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely fasten to the 2 tabs on the lower part of the rear plate.
  • Page 422 Left-side tubing (1) Lead the tubing and drain hose through the wall, allowing sufficient length for connection. Then bend the tubing using a tube bender to make the attachment. (Fig. 5-28) Rear panel (2) Switch the drain hose and drain cap. Hole in wall Switching drain hose and drain cap (a) Locate the drain hose and the drain cap.
  • Page 423 To unmount indoor unit (1) Remove the screw cover on the bottom surface. (Fig. 5-34) (2) Fasten the frame to the rear panel using the 2 supplied tapping screws 4 × 10 mm. (Fig. 5-34) (3) Press the 2 marks on the lower part of the indoor unit and unlatch the tabs.
  • Page 424 (Wall Mounted) Part Name Figure Q’ty Truss-head Phillips Tapping screw 4 × 20 mm Truss-head Phillips Tapping screw 4 × 10 mm Flare insulation 1-414...
  • Page 425: Selecting The Installation Site Low Silhouette Ducted Type (F1)

    6. SELECTING THE INSTALLATION SITE Low Silhouette Ducted Type (F1) Indoor Unit AVOID: areas where leakage of flammable gas may be expected. places where large amounts of oil mist exist. direct sunlight. locations near heat sources which may affect the performance of the unit.
  • Page 426 HOW TO INSTALL THE INDOOR UNIT Low Silhouette Ducted Type (F1 Type) Unit: mm 6-1. Required Minimum Space for Installation and Service A (Suspension bolt pitch) This air conditioner is usually installed above the ceiling so Electrical that the indoor unit and ducts are not visible. Only the air component box intake and air outlet ports are visible from the unit bottom.
  • Page 427 6-2. Suspending the Indoor Unit Suspension bolt Depending on the ceiling type: • Insert suspension bolts (Fig. 6-3) Nuts and washers (use for upper and lower) • Use existing ceiling supports or construct a suitable support (Fig. 6-4). Suspension lug Hole-in-anchor Concrete Insert...
  • Page 428 6-3. Installing the Drain Pipe 300 mm or less (1) Prepare standard hard PVC pipe (O.D. 32 mm) for the 500 mm or less drain and use the supplied hose band to prevent water Good leaks. The PVC pipe must be purchased separately. The transparent drain part on the unit allows you to check drainage.
  • Page 429 6-4. Connecting Duct to Air Intake Port Side Bracket (1) First pull out a filter in the direction of the electrical equipment box in the unit. (Fig. 6-15) The pre-installed filter will not be used any more. (2) Then remove the seal packing, bracket and filter attached to the side of the air intake port.
  • Page 430 6-5. External Static Pressure Setting Choose one of the following methods from “a”, “b”, “c” or “d” as shown in the flow chart (within the dotted lines) and then make the setting accordingly. a. No setting modification............: Use-as-is at shipment (there are cases in which the setting may differ from the shipment setting when reset after once setting the external static pressure.) b.
  • Page 431 Refer to Table 6-4 and Fig. 6-18 for details on the relationship between the value of item code “b0” and the external stati c pressure. When set in group control (connecting multiple indoor units with one wired remote controller), set each indoor unit to item code “b0”.
  • Page 432 6-7. Operating the Timer Remote Controller (CZ-RTC2) Table 6-4 Setting the external static pressure Setting Item Code “ ” Indoor unit Item code 36, 45, 50, 60, 71 100, 125, 140 Press and hold down the buttons External static pressure of the rated simultaneously for 4 or more seconds.
  • Page 433 Indoor Fan Performance Item code “ ” M M M M M M M L L L L L L L L 1 -2 L L L L 1 -3 100 type 36, 45 types PQ diagram PQ diagram 1 -3 1 -2 1 -3 1 -2...
  • Page 434 (Low Silhouette Ducted) Part Name Figure Q’ty Remarks For suspending indoor Washer unit from ceiling Flare insulator For gas and liquid tubes Insulating For gas and liquid tubes tape flare nuts Drain For drain hose joint insulator Hose band For securing drain hose For drain hose joint Packing (hard material)
  • Page 435 Optional Duct Frange How to Install Duct Frange 4 circle duct frange (CZ-160DAF2) 3 circle duct frange (CZ-90DAF2) 2 circle duct frange (CZ-56DAF2) 1. Remove the air outlet duct frange. 2. Attach the duct frange to the side of the unit with the supplied screws. Duct frange 1-425...
  • Page 436 Dimensional Diagram : CZ-56DAF2 unit: mm Ø200 Ø200 (45) (170) Dimensional Diagram : CZ-90DAF2 unit: mm Ø200 Ø200 Ø200 (45) Dimensional Diagram : CZ-160DAF2 unit: mm Ø200 Ø200 Ø200 Ø200 1240 (45) (185) 1-426...
  • Page 437: Selecting The Installation Site Ducted Type (N1)

    7. SELECTING THE INSTALLATION SITE Ducted Type (N1) Indoor Unit AVOID: areas where leakage of flammable gas may be expected. places where large amounts of oil mist exist. direct sunlight. locations near heat sources which may affect the performance of the unit. locations where external air may enter the room directly.
  • Page 438 SELECTING THE LOCATION FOR THE INDOOR UNIT 7-1. Required Minimum Space for Installation and Service Provide a check port on the piping side ceiling for repair and maintenance. Install the indoor unit once the following conditions are satisfied and after receiving the customer approval. The indoor unit must be within a maintenance space.
  • Page 439 NOTE NAME Q'TY Pipe connection (gas) O.D. Ø12.7 Flared Pipe connection (liquid) O.D. Ø6.35 Flared Drain pipe connection Female screw PT1" Duct connection Hanger Control box 650 (P65 x 10) Air Flow 22-Ø4.5 24-Ø4.5 585 (P65 x 9) Air Flow UNIT:mm S-36PN1E5 Drain pipe connection...
  • Page 440 NOTE NAME Q'TY Pipe connection (gas) O.D. Ø15.88 Flared Pipe connection (liquid) O.D. Ø9.52 Flared Drain pipe connection Female screw PT1" Duct connection Hanger Control box 1260 1160 1040(P65x16) 44-Ø4.5 46-Ø4.5 975 (P65 x 15) 57.5 1090 Air Flow 1320 1200 Drain pipe connection UNIT:mm...
  • Page 441 7-2. Suspending the Indoor Unit Depending on the ceiling type: • Insert suspension bolts (Fig. 7-3) • Use existing ceiling supports or construct a suitable support (Fig. 7-4). Hole-in-anchor Hole-in-plug Concrete Insert Ceiling tiles Ceiling support Suspension bolt (M10 or 3/8") (field supply) Fig.
  • Page 442 7-3. Installing the Drain Pipe Drainage hole (1) Prepare standard hard PVC pipe (O.D. 32 mm) for the drain and use the supplied hose band to prevent water leaks. The PVC pipe must be purchased separately. Thermal insulator Hose clip (Accessories) CAUTION (Accessories)
  • Page 443 7-5. External Static Pressure Setting for Dc Fan Motor Model Choose one of the following methods from “a”, “b”, “c” or “d” as shown in the flow chart (within the dotted lines) and then make the setting accordingly. a. No setting modification............: Use-as-is at shipment (there are cases in which the setting may differ from the shipment setting when reset after once setting the external static pressure.) b.
  • Page 444 Refer to Table 7-3 and Fig. 7-18 for details on the relationship between the value of item code “b0” and the external static pressure. When set in group control (connecting multiple indoor units with one wired remote controller), set each indoor unit to item code “b0”. When amending the setting after selecting [ b.
  • Page 445 7-7. Operating the Timer Remote Controller (CZ-RTC2) Table 7-3 Setting the external static pressure Setting Item Code “ ” Indoor unit Item code Press and hold down the buttons 60, 71 100, 125, 140 simultaneously for 4 or more seconds. External static pressure of the rated , the Unit No., Item Code and Detailed Data will air flow volume (Pa)
  • Page 446 Indoor Fan Performance Item code “ ” M M M M M M M 1 -2 1 -3 S-60PN1E5 • S-71PN1E5 S-125PN1E5 P-Q diagram P-Q diagram Limit line Limit line Air Volume (m /min.) Air Volume (m /min.) S-100PN1E5 S-140PN1E5 P-Q diagram P-Q diagram Limit line...
  • Page 447 7-8. External Static Pressure Setting for AC Fan Motor Model To apply to following models S-36PN1E5 , S-45PN1E5 , S-50PN1E5 There are two tap connector located in indoor unit control box can be selected. The “blue connector” is standard tap, use-as-is at shipment. For high static pressure duct, switch Fan Motor connector to plug in boost tap “white connector”...
  • Page 448 (Ducted) Part Name Figure Q’ty Remarks For suspending indoor unit Washer from ceiling Flare insulator For gas and liquid tubes Hose band For securing drain hose Foam drain For drain hole socket (another side of drain hose) Drain hose Flange For inlet duct installation Screw Use M10 for suspension bolts.
  • Page 449: How To Select Ahu System

    1-12. How to select AHU system AHU system selection guideline System lineup Capacity Outdoor combination Connectable AHU-kit combination 10 kW U-100PE1E8 U-100PE1E5 CZ-280PAH1 CZ-280PAH1 12.5 kW U-125PE1E8 U-125PE1E5 CZ-280PAH1 CZ-280PAH1 14 kW U-140PE1E8 U-140PE1E5 CZ-280PAH1 CZ-280PAH1 * Single connection type only * Mix connection with standard indoor units is not allowed.
  • Page 450 Installation   Installation of Strainer (Field supplied) Attach the strainer to the side of the outdoor unit for Gas & Liquid piping. (See the “System Overview” on previous page.) Thermistor for Liquid pipe and Heat exchanger pipe middle Liquid pipe thermistor Attach the liquid pipe thermistor Cover the thermistor Cover the aluminum...
  • Page 451 Blower operation signal and protection signal Blower signal output Power supply Minimum applicable load DC 5 V, 1 mA Maximum applicable load AC 230 V, 2 A X1 : Relay (field supply) Blower protect input SW 1 : operation command (field supply) AC 220 ~240 V, 0.1 A Limitation of AHU When the AHU is selected, there are some limitations.
  • Page 452 Restriction on the number of passes of the heat exchanger hairpin Minimum number of passes = Number of steps × Distance between tube sheets × Number of rows × 1.5 ×10 <For example> Number of steps Distance between tube sheets 1000 [mm] Number of rows Minimum number of passes = 12 ×...
  • Page 453: Capacity Table

    1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C...
  • Page 454 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C...
  • Page 455 14.8 4.68 13.8 4.87 10.1 3.98 230V 13.6 13.6 3.86 13.6 13.6 4.15 13.1 13.1 4.41 12.2 12.2 4.59 3.75 S-45PU1E5×3 240V U-125PE1E5 14.6 12.1 4.03 14.6 12.2 4.32 14.0 11.8 4.60 13.0 11.5 4.78 3.91 50Hz (U-125PE1E8) 16.0 4.16 16.0...
  • Page 456 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C...
  • Page 457 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 458 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 459 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 460 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceilling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 461 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 462 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 463 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 464 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 465 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 466 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 467 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 468 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C...
  • Page 469 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C...
  • Page 470 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C...
  • Page 471 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 472 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 473 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 474 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 475 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 476 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 477 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 478 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 46°C Source...
  • Page 479 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C...
  • Page 480 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C...
  • Page 481 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C...
  • Page 482 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 483 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 484 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 485 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 486 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 487 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 488 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C...
  • Page 489 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C...
  • Page 490 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 491 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 492 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C...
  • Page 493 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 494 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 495 1-13. Capacity Table :Cooling Capacity SHC :Sensible Heat Capacity 1. Cooling Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ducted Type unit : kW Outdoor air intake temp(°C D.B.) Ambient Power Model Return 25°C 30°C 35°C 40°C 43°C Source...
  • Page 496: Heating Capacity Performance Data

    1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.79 1.84 2.19...
  • Page 497 15.0 5.28 15.0 4.65 15.0 3.94 (3 phase) 220V 16.7 5.52 17.2 5.43 17.3 4.91 17.3 4.33 17.3 3.66 230V S-45PU1E5×3 240V U-125PE1E5 15.5 5.84 15.9 5.74 16.0 5.20 16.0 4.58 16.0 3.87 50Hz (U-125PE1E8) 1 phase 14.5 5.93 14.9 5.84...
  • Page 498 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.00 2.06...
  • Page 499 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.88...
  • Page 500 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.03 2.08 2.47 2.96...
  • Page 501 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.88 2.90 2.86...
  • Page 502 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.79 1.84 2.19 2.62...
  • Page 503 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.88 2.90 2.86...
  • Page 504 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.91 1.96 2.33...
  • Page 505 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.88 2.90...
  • Page 506 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Sihouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.87 1.92...
  • Page 507 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.88...
  • Page 508 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.96 2.02 2.39 2.87...
  • Page 509 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 220V 2.90 2.92 2.88...
  • Page 510 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.89 1.92 2.05...
  • Page 511 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.95 2.04 2.38...
  • Page 512 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit 4-Way Cassette 60×60 Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.09 2.19...
  • Page 513 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.89 1.92 2.05 2.29...
  • Page 514 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.02 2.11 2.47 2.68...
  • Page 515 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.89 1.92 2.05 2.29...
  • Page 516 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ceiling Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.95 2.04 2.38 2.59...
  • Page 517 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.92 1.96 2.09...
  • Page 518 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Wall Mounted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.98 2.07 2.42...
  • Page 519 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.80 1.83...
  • Page 520 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Low Silhouette Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 1.86 1.95...
  • Page 521 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Single Unit Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.12 2.16 2.30 2.57...
  • Page 522 1-13. Capacity Table :Cooling Capacity 2. Heating Capacity Performance Data IPT :Cooling Power Consumption • Combination of Multiple Unit Ducted Type unit : kW Outdoor air intake temp(°C W.B.) Ambient Power Model Return -5°C 0°C 6°C 10°C 15°C Source 2.20 2.30 2.70 2.93...
  • Page 523: Product Fiche

    1-14. Product Fiche U-50PE1E5 1-513...
  • Page 524 1-14. Product Fiche U-60PE1E5 1-514...
  • Page 525 1-14. Product Fiche U-60PEY1E5 1-515...
  • Page 526 1-14. Product Fiche U-71PE1E5 1-516...
  • Page 527 1-14. Product Fiche U-71PE1E8 1-517...
  • Page 528 1-14. Product Fiche U-71PEY1E5 1-518...
  • Page 529 1-14. Product Fiche U-100PE1E5 1-519...
  • Page 530 1-14. Product Fiche U-100PE1E5 1-520...
  • Page 531 1-14. Product Fiche U-100PE1E5 1-521...
  • Page 532 1-14. Product Fiche U-100PE1E8 1-522...
  • Page 533 1-14. Product Fiche U-100PE1E8 1-523...
  • Page 534 1-14. Product Fiche U-100PEY1E5 1-524...
  • Page 535 1-14. Product Fiche U-100PEY1E8 1-525...
  • Page 536 – MEMO – 1-526...
  • Page 537: Section 2. Test Run

    2. TEST RUN n PRECAUTIONS REGARDING TEST RUN ................ 2-2 n CHECKS AFTER INSTALLATION HAVE COMPLETED ........... 2-3 n REGARDING DELIVERY TO THE CUSTOMER ..............2-3...
  • Page 538: Precautions Regarding Test Run

    PRECAUTIONS REGARDING TEST RUN Check Before Test Run Content check Power supply cable Is the wire set up and connected as described in the instructions? Check for any phase Indoor/outdoor connection wire sequence. Earth wire Are the wire connection’s screws loose? Is the open and close device / leakage breaker installed? Is the power supply cable’s thickness and length appropriately measured as described in the instructions?
  • Page 539: Checks After Installation Have Completed

    Outdoor main PCB CHK pin RUN pin MODE pin *MODE pin: factory setting is cooling operation mode. CHECKS AFTER INSTALLATION HAVE COMPLETED Check the following items after completing installation. Is there a short circuit with the intake air fl ow? Is the insulation secure? (Refrigerant piping) Are there any errors with the wiring? Are the terminal screws loose? Tightening torque (Unit: N •...
  • Page 540 – MEMO –...
  • Page 541: Section 3. Electrical Data

    3. ELECTRICAL DATA 3-1. Indoor Units (Electric Wiring Diagram Schematic Diagram) ........3-2 4-Way Cassette Type ..........................3-2 4-Way Cassette 60 × 60 type ........................3-3 Ceiling Type ............................3-4 Wall Mounted Type ..........................3-7 Low Silhouette Ducted Type ........................3-8 Ducted Type ............................
  • Page 542 3-1. Indoor Units 4-Way Cassette Type S-36PU1E5 / S-45PU1E5 / S-50PU1E5 / S-60PU1E5 / S-71PU1E5 / S-100PU1E5 / S-125PU1E5 / S-140PU1E5 Electric Wiring Diagram...
  • Page 543 3-1. Indoor Units 4-Way Cassette 60 × 60 Type S-36PY1E5 / S-45PY1E5 / S-50PY1E5 Electric Wiring Diagram...
  • Page 544 3-1. Indoor Units Ceiling Type S-36PT1E5 / S-45PT1E5 / S-50PT1E5 / S-60PT1E5 / S-71PT1E5         S-100PT1E5 / S-125PT1E5 / S-140PT1E5 Electric Wiring Diagram...
  • Page 545 3-1. Indoor Units Ceiling Type S-36PT1E5 / S-45PT1E5 / S-50PT1E5 / S-60PT1E5 / S-71PT1E5        S-100PT1E5 / S-125PT1E5 / S-140PT1E5 Schematic Diagram...
  • Page 546 3-1. Indoor Units Ceiling Type S-36PT2E5 / S-45PT2E5 / S-50PT2E5 / S-60PT2E5 / S-71PT2E5 S-100PT2E5 / S-125PT2E5 / S-140PT2E5 Electric Wiring Diagram...
  • Page 547 3-1. Indoor Units Wall Mounted Type S-36PK1E5 / S-45PK1E5 / S-50PK1E5 / S-60PK1E5 / S-71PK1E5 Electric Wiring Diagram...
  • Page 548 3-1. Indoor Units Low Silhouette Ducted Type S-36PF1E5 / S-45PF1E5 / S-50PF1E5 / S-60PF1E5 / S-71PF1E5                S-100PF1E5 / S-125PF1E5 / S-140PF1E5 Electric Wiring Diagram...
  • Page 549 3-1. Indoor Units Ducted Type S-36PN1E5 / S-45PN1E5 / S-50PN1E5 Electric Wiring Diagram...
  • Page 550 3-1. Indoor Units Ducted Type S-60PN1E5 / S-71PN1E5 / S-100PN1E5 / S-125PN1E5 / S-140PN1E5 Electric Wiring Diagram 3-10...
  • Page 551 3-2. Outdoor Units Single-phase U-50PE1E5 3-11...
  • Page 552 3-2. Outdoor Units Single-phase U-50PE1E5 3-12...
  • Page 553: Outdoor Units (Electric Wiring Diagram)

    3-2. Outdoor Units Single-phase U-60PE1E5 / U-71PE1E5 3-13...
  • Page 554 3-2. Outdoor Units Single-phase U-100PE1E5 / U-125PE1E5 / U-140PE1E5 3-14...
  • Page 555 3-2. Outdoor Units Single-phase U-60PEY1E5 / U-71PEY1E5 3-15...
  • Page 556 3-2. Outdoor Units Single-phase U-60PEY1E5 / U-71PEY1E5 3-16...
  • Page 557 3-2. Outdoor Units Single-phase U-100PEY1E5 / U-125PEY1E5 3-17...
  • Page 558 3-2. Outdoor Units 3-phase U-71PE1E8 3-18...
  • Page 559 3-2. Outdoor Units 3-phase U-100PEY1E8 / U-125PEY1E8 3-19...
  • Page 560 3-2. Outdoor Units 3-phase U-100PE1E8 / U-125PE1E8 / U-140PE1E8 /U-140PEY1E8 3-20...
  • Page 561: Section 4. Control Functions

    4. CONTROL FUNCTIONS 4-1. Room Temperature Control ..................4-2 4-2. Heating Standby ......................4-4 4-3. Automatic Fan Speed Control ..................4-5 4-4. Drain Pump Control ....................... 4-6 4-5. Automatic Heating/Cooling Control ................4-7 4-6. Automatic Flap Control ....................4-8 4-7. Filter Sign ........................4-8 4-8.
  • Page 562: Room Temperature Control

    4-1. Room Temperature Control The body sensor or remote controller sensor detects temperature in the room. The detected temperature is called the room temperature. The body sensor is the one contained in the indoor unit. Body sensor is enabled Remote controller sensor is enabled Set temp.
  • Page 563 Remote controller sensor is enabled Remote controller sensor is enabled Set temp. in remote Set temp. in remote controller controller Detected temp. by Detected temp. by 30.0 27.5 27.0 17.0 20.5 21.0 sensor sensor Detected temp. by Detected temp. by 30.0 27.5 27.0...
  • Page 564: Heating Standby

    4-2. Heating Standby In heating mode, the indoor fan speed decreases to prevent cold air discharge from the indoor unit. During this time, (heating standby) is displayed on the remote controller. This condition occurs in the following cases. Thermostat OFF Defrosting operation Indoor heat exchanger liquid temperature (E1) <...
  • Page 565: Automatic Fan Speed Control

    4-3. Automatic Fan Speed Control The indoor fan mode is controlled as shown below during the automatic fan mode. The fan mode does not change for 3 minutes during cooling operation and 1 minute during heating operation once it is changed. The values in the parenthesis are when the remote controller sensor is enabled.
  • Page 566: Drain Pump Control

    4-4. Drain Pump Control The drain pump operates in the following conditions. Cooling thermostat ON The fl oat switch worked. The drain pump may often operate for a while when the cooling thermostat turns OFF or the indoor unit is stopped. The drain pump can be turned on when the cooling thermostat is OFF if the setting is made to prevent water collected in the drain pan for a long time.
  • Page 567: Automatic Heating/Cooling Control

    4-5. Automatic Heating/Cooling Control The operating mode is selected according to the set temperature and room temperature when the operation is started. Room temperature > set temperature in remote controller – 1˚C → Cooling mode Room temperature < set temperature in remote controller – 1˚C → Heating mode The set temperature is corrected according to the operating mode.
  • Page 568: Automatic Flap Control

    4-6. Automatic Flap Control The flap position can be selected from 5 positions. Close Close (Fully open) (Fully open) Except ceiling type (T2 type) For ceiling type (T2 type) Operating mode Flap position Cooling/Dry Heating The flap will be closed automatically when the indoor unit is stopped. Close: Types K1, T1, T2, U1, Y1 The flap closes once and moves to the set position when the operating mode is changed.
  • Page 569: Fan Control During Dry Mode

    4-8. Fan Control during Dry Mode The fan control during dry mode is as follows. T (deg) Set temp. in remote controller Fan mode A: Fan mode set in the remote controller B: Fan mode is L during thermostat ON, LL during thermostat OFF For details on T, refer to “4-1.
  • Page 570: Parameter

    4-11. Parameter Heat/cool switching Correction temp. (heating) correction temp. (automatic heat/cool) Type Model Setting at time of factory Setting at time of factory shipment shipment 4-Way Cassette 4 deg 2 deg 4-Way Cassette 60×60 4 deg 2 deg T1, T2 Ceiling 4 deg 2 deg...
  • Page 571 4-12. Control Functions Single-phase : U-50PE1E5 Single-phase : U-60PEY1E5, 71PEY1E5 4-12-1. Indoor Air Temperature Control The thermostat is switched on and off in accordance with T shown below. T= (Indoor air temperature) - (Temperature set with the remote controller) In the body thermostat mode Indoor air temperature = (Body sensor) - (Shift temperature *) (setting at factory shipment) In the remote controller thermostat mode Indoor air temperature = (Remote controller sensor)
  • Page 572 1) Indoor Air Temperature Control By the control method, not only the thermostat is switched on and off, as explained section “4-12-1”. Indoor Air Temperature Control ", but also the frequency of the compressor's inverter is controlled in accordance with T and fluctuations in indoor air temperature.
  • Page 573 4) Cooling High-Load Prevention Control This system control is performed to limit the inverter frequency in order to restrict high pressure’s abnormal increase and high-load operating prevention in the cooling mode. In accordance with the temperature of the outdoor heat exchanger temperature sensors (C1, C2), such controls are performed as to halting the operations of the indoor unit, decreasing the inverter frequency and restricting its increase, etc.
  • Page 574 6) Cooling Freeze Prevention Control The following control is performed during cooling operations (including dry mode operation), in accordance with whichever of the indoor heat exchanger temperatures (E1 or E2) is lower. (See the chart below.) If the temperature remains in the "J" zone (decreasing operation frequency and thermostat OFF zone) for 6 minutes, the operating frequency of the compressor is decreased.
  • Page 575 8) Defrosting Control This control function removes frost that has adhered to the outdoor heat exchanger during the heating operation. The control is performed to prevent the deterioration of the heating capabilities attributed to the adherence of frost, and to prevent the crack or crush of pipes attributed to the accretion of ice. The following control is performed in accordance with the ambient temperature and the outdoor heat exchanger temperature sensor (C1).
  • Page 576 Ending Defrosting Defrosting operations are ended when the following conditions are satisfied. • Ending defrosting conditions When the temperature of the outdoor heat exchanger temperature sensor (C1) is 12°C or higher. When the temperature of the outdoor heat exchanger temperature sensor (C1) is 7°C or higher for consecutive 60 seconds.
  • Page 577 Single-phase : U-60PE1E5, 71PE1E5, 100PE1E5, 125PE1E5, 140PE1E5 3-phase : U-71PE1E8, 100PE1E8, 125PE1E8, 140PE1E8 Single-phase : U-100PEY1E5, 125PEY1E5 3-phase : U-100PEY1E8, 125PEY1E8, 140PEY1E8 4-12-3. Indoor Air Temprature Control The thermostat is switched on and off in accordance with T shown below. T= (Indoor air temperature) - (Temperature set with the remote controller) In the body thermostat mode Indoor air temperature = (Body sensor) - (Shift temperature *)
  • Page 578 1) Indoor Air Temperature Control By the control method, not only the thermostat is switched on and off, as explained section “4-12-3”. Indoor Air Temperature Control ", but also the frequency of the compressor's inverter is controlled in accordance with T and fluctuations in indoor air temperature.
  • Page 579 4) Condensation Temperature Control (cooling) This system control is performed to limit the inverter frequency in order to restrict high pressure’s abnormal increase and high-load operating prevention in the cooling mode. In accordance with the temperature of the outdoor heat exchanger temperature sensors (C1, C2), such controls are performed as to halting the operations of the indoor unit, decreasing the inverter frequency and restricting its increase, etc.
  • Page 580 6) Cooling Freeze Prevention Control The following control is performed during cooling operations (including dry mode operation), in accordance with whichever of the indoor heat exchanger temperatures (E1 or E2) is lower. (See the chart below.) (a) Frequency will not be decreased less than 6 minutes after thermostat ON. (b) The threshold value is increased in accordance with the indoor load (differences of temperature).
  • Page 581 8) Defrosting Control This control function removes frost that has adhered to the outdoor heat exchanger during the heating operation. The control is performed to prevent the deterioration of the heating capabilities attributed to the adherence of frost, and to prevent the crack or crush of pipes attributed to the accretion of ice. The following control is performed in accordance with the ambient temperature and the outdoor heat exchanger temperature sensor (C1).
  • Page 582 Ending Defrosting Defrosting operations are ended when the following conditions are satisfied. • Ending defrosting conditions When the temperature of the outdoor heat exchanger temperature sensor (C1) is 12°C or higher. When the temperature of the outdoor heat exchanger temperature sensor (C1) is 10°C or higher for consecutive 60 seconds.
  • Page 583: Outdoor Units Control Pcb

    4-13. Outdoor Unit Control PCB 4-13-1. Single-Phase Unit CR-PCB CR-50PE1E5:Up side (U-50PE1E5) PUMP DOWN(CN042) MODE(CN031) TERMINAL JP007 RC plug(RC-P) JP001 S003 (R.C.ADD) S002 (R.C.ADD) D007 (LED1) D008(LED2) A.ADD(CN041) C-CHK(CN033) (COOL_CHECK) POWER LED (D225) EEPROM memory IC (IC006) LED for EEPROM memory IC (D014) (CN01) 4-23...
  • Page 584 CR-PCB CR-50PE1E5:Bottom side (U-50PE1E5) RC plug (RC-P) OC plug (OC) EMG plug (CN012) (EMG) SILENT Suction temp. (TS) (4P pin 3-4) Comp discharge temp. (TD) (4P pin 1-2) Outdoor air temp. (TO) Inlet temperature sensor in heat exchanger (C1) Intermediate temperature sensor in heat exchanger (C2)
  • Page 585 CR-PCB CR-60PEY1E5:Up side (U-60PEY1E5) PUMP DOWN(CN042) MODE(CN031) TERMINAL JP007 RC plug(RC-P) JP001 S003 (R.C.ADD) S002 (R.C.ADD) D007 (LED1) D008(LED2) A.ADD(CN041) C-CHK(CN033) (COOL_CHECK) POWER LED (D225) EEPROM memory IC (IC006) LED for EEPROM memory IC (D014) (CN01) 4-25...
  • Page 586 CR-PCB CR-60PEY1E5:Bottom side (U-60PEY1E5) RC plug (RC-P) OC plug (OC) EMG plug (CN012) (EMG) SILENT Suction temp. (TS) (4P pin 3-4) Comp discharge temp. (TD) (4P pin 1-2) Outdoor air temp. (TO) Inlet temperature sensor in heat exchanger (C1) Intermediate temperature sensor in heat exchanger (C2)
  • Page 587 CR-PCB CR-71PEY1E5:Up side (U-71PEY1E5) PUMP DOWN(CN042) MODE(CN031) TERMINAL JP007 RC plug(RC-P) JP001 S003 (R.C.ADD) S002 (R.C.ADD) D007 (LED1) D008(LED2) A.ADD(CN041) C-CHK(CN033) (COOL_CHECK) POWER LED (D225) EEPROM memory IC (IC006) LED for EEPROM memory IC (D014) (CN01) 4-27...
  • Page 588 CR-PCB CR-71PEY1E5:Bottom side (U-71PEY1E5) RC plug (RC-P) OC plug (OC) EMG plug (CN012) (EMG) SILENT Suction temp. (TS) (4P pin 3-4) Comp discharge temp. (TD) (4P pin 1-2) Outdoor air temp. (TO) Inlet temperature sensor in heat exchanger (C1) Intermediate temperature sensor in heat exchanger (C2)
  • Page 589 4-13-2. Single-Phase Unit CR-PCB A746894 (U-60PE1E5, U-71 PE1E5) EEPROM memory IC POWER LED JP001 (IC18) (D514) SILENT (CN- SILENT) S003 LED for EEPROM S002 memory PUMP (D330) DOWN A.ADD D302 (LED1) D303 (LED2) MODE CN-OPT1 STOP CN-OPT2 TEST Inlet temperature Comp sensor in heat OC plug...
  • Page 590 CR-PCB A746844 (U-100PE1E5) EEPROM memory IC POWER LED JP001 (IC18) (D514) SILENT (CN- SILENT) S003 LED for EEPROM S002 memory PUMP (D330) DOWN A.ADD D302 (LED1) D303 (LED2) MODE CN-OPT1 STOP CN-OPT2 Inlet TEST temperature Comp sensor in heat OC plug EMG plug discharge exchanger...
  • Page 591 CR-PCB A746845 (U-125PE1E5, U-140PE1E5) EEPROM memory IC POWER LED JP001 (IC18) (D514) SILENT (CN- SILENT) S003 LED for EEPROM S002 memory PUMP (D330) DOWN A.ADD D302 (LED1) D303 (LED2) MODE CN-OPT1 STOP CN-OPT2 TEST Inlet temperature Comp sensor in heat OC plug EMG plug discharge...
  • Page 592 CR-PCB A747179 (U-100PEY1E5) EEPROM memory IC POWER LED (IC18) (D514) S003 JP001 PUMP DOWN CN-SILENT S002 LED for EEPROM memory (D330) A.ADD MODE STOP D302 MOV plug (LED1) (CN-MOV1) D303 High-pressure (LED2) switch plug (CN-63PH) CN-OPT1 Suction temp (CN-TS) CN-OPT2 OC plug (CN-OC) EMG plug...
  • Page 593 CR-PCB A747180 (U-125PEY1E5) EEPROM memory IC POWER LED (IC18) (D514) S003 JP001 PUMP DOWN CN-SILENT S002 LED for EEPROM memory (D330) A.ADD MODE STOP D302 MOV plug (LED1) (CN-MOV1) D303 High-pressure (LED2) switch plug (CN-63PH) CN-OPT1 Suction temp (CN-TS) CN-OPT2 OC plug (CN-OC) EMG plug...
  • Page 594 HIC-PCB A746895 (U-60PE1E5, U-71PE1E5) 4WAY Valve (CN-20S) CN-VDC- CN-VDC+ 4-34...
  • Page 595 HIC-PCB (continued) A746846 (U-100PE1E5) 4WAY Valve (CN-20S) CN-VDC- CN-VDC+ 4-35...
  • Page 596 HIC-PCB (continued) A746847 (U-125PE1E5, U-140PE1E5) 4WAY Valve (CN-20S) CN-VDC- CN-VDC+ 4-36...
  • Page 597 HIC-PCB A746846 (U-100PEY1E5) 4WAY Valve (CN-20S) CN-VDC- CN-VDC+ 4-37...
  • Page 598 HIC-PCB (continued) A746847 (U-125PEY1E5) 4WAY Valve (CN-20S) CN-VDC- CN-VDC+ 4-38...
  • Page 599 4-13-3. 3-Phase Unit CR-PCB A746968 (U-71PE1E8) A746967 (U-100PE1E8, U-125PE1E8, U-140PE1E8) A747596 (U-140PEY1E8) TEST JP001 POWER LED EEPROM memory IC (D514) (IC18) LED for EEPROM memory (D330) S003 S002 SILENT (CN- SILENT) PUMP DOWN A.ADD D302 (LED1) MODE D303 (LED2) STOP CN-PRY1 CN-OPT1 CN-OPT2...
  • Page 600 CR-PCB A747247 (U-100PEY1E8, U-125PEY1E8) PUMP DOWN POWER LED S003 LED for (D514) EEPROM EEPROM memory IC memory IC JP001 (IC18) (D330) S002 SILENT (CN-SILENT) A.ADD MODE STOP D302 MOV plug (LED1) (CN-MOV1) CN-PRY2 D303 CN-PRY1 (LED2) High-pressure switch plug CN-OPT1 (CN-63PH) CN-OPT2 Suction temp...
  • Page 601 HIC-PCB A746970 (U-71PE1E8) A746969 (U-100PE1E8, U-125 PE1E8, U-140PE1E8, U-140PEY1E8) 4WAY Valve (CN-20S) CN-VDC- CN-VDC+ 4-41...
  • Page 602 HIC-PCB A747248 (U-100PEY1E8, U-125PEY1E8) 4WAY Valve (CN-20S) CN-VDC+ CN-VDC- 4-42...
  • Page 603: Functions Of Outdoor Unit Pcb

    4-14. Functions of Outdoor Unit PCB CN-A.ADD 2P plug : Automatic address setting pin • Short-circuit this pin for 1 second or longer to automatically set the addresses at the indoor units that are connected to that outdoor unit and are within the same system.
  • Page 604 LED 1 (D302) LED (red × 2) LED 2 (D303) • LED 1 and 2 blink alternately while automatic address setting is in progress. • Display the alarm contents for alarms that are detected by the outdoor unit. Power LED LED (green): Power indicator (D330) Indicates the DC 5V power on the outdoor unit control PCB.
  • Page 605 Table 1. Setting the System Address [S002: Rotary switch (yellow), S003: 2P DIP (black)] S003 setting S002 setting (system Outdoor system address No. address switch) 1P (10s digit) 2P (20s digit) 1 refrigerant system only Link wiring 4-45...
  • Page 606: Self-Diagnostics Function Table

    4-15. Self-Diagnostics Function Table • Causes and corrections in instances when automatic address setting cannot be started. Trouble Cause and correction The power LED on the outdoor unit control PCB does not turn ON. Check for any errors in the power wiring to the outdoor unit, and check for a missing phase.
  • Page 607 Check items Check that the indoor unit power is turned ON. Check that the inter-unit control wiring is connected correctly. (Check that there are no open circuits, short circuits, terminal plugs, incorrect wiring to the remote controller terminals, or similar problems.) Check that the remote controller wiring is connected correctly.
  • Page 608 • The outdoor unit maintenance remote controller can be used to check the alarm display. The number of times that LED 1 and 2 blink on the outdoor unit control PCB can be used to check the alarm display. (Refer to "Checking the LED 1 and 2 Alarm Display on the Outdoor Unit Control PCB.") Alarm Alarm Meaning Code...
  • Page 609: Section 5. Trouble Diagnosis

    5. TROUBLE DIAGNOSIS 5-1. Contents of Remote Controller Switch Alarm Display .......... 5-2 5-2. Outdoor Unit Control Panel LED Display ..............5-4 5-3. PAC System Alarm Codes ..................5-5 5-4. Inspection of Parts (Outdoor Unit) ................5-68 5-5. Symptom: Thermostat in OFF continues or cycles OFF & ON too frequently ..5-69 5-6.
  • Page 610: Contents Of Remote Controller Switch Alarm Display

    5-1. Contents of Remote Controller Switch Alarm Display Blinking: OFF: Wired Wireless remote remote controller control receiver display display Possible cause of malfunction Remote controller is Error in receiving serial communication signal Serial Operating lamp detecting error signal from (Signal from main indoor unit in case of group control) blinking communication indoor unit.
  • Page 611 Blinking: OFF: Wired Wireless remote remote controller control receiver display display Possible cause of malfunction Compressor discharge temperature trouble Operating and Activation of Protective device in outdoor heating ready protective unit is activated. High pressure trouble lamp blinking device altemately AC power supply trouble Insufficient gas level detected Compressor overcurrent trouble...
  • Page 612: Outdoor Unit Control Panel Led Display

    5-2. Outdoor Unit Control Panel LED Display : ON : Blinking : OFF ) LED1 LED2 Display meaning D302 D303 After the power is turned ON (and automatic address setting is not in progress), no communica- tion with the indoor units in that system is possible. (Both ON) After power is turned ON (and automatic address setting is not in progress), 1 or more indoor units are confirmed in that system;...
  • Page 613: Pac System Alarm Codes

    5-3. PAC System Alarm Codes Alarms for outdoor units Alarm Alarm Meaning Code Remote Controller Reception Error Remote Controller Transmission Error Error in Indoor Unit Receiving Signal from Remote Controller (central) Error in Indoor Unit Receiving Signal from the Outdoor Unit Error in Indoor Unit Transmitting Signal to the Outdoor Unit Outdoor Unit Failed to Receive Serial Communication Signals from Indoor Unit Duplicate Indoor Unit Address Settings Error...
  • Page 614 Symptoms and Parts to Inspect Remote Alarm Eliminating controller Judgement conditions Judgement and correction contents condition of alarm alarm display Abnormal discharge Stops when temp. exceeds Recovery at restart 1. Check refrigerant cycle (gas temperature error leak). • Discharge temp. Alarm output on 5 pre-trips 2.Trouble with electronic detected at or...
  • Page 615 Check Prior to Auto Address Setting If an outdoor unit displays an alarm, conduct this process after diagnosing the problem. 1 Auto Address Is the power of the indoor unit(s) and outdoor unit(s) on? Power on Indoor/ Has the wiring of the indoor/outdoor control line been completed? outdoor Is it all connected? Connect the wiring...
  • Page 616 E01 Remote Controller Reception Error (When indoor unit(s) are connected) Error Detection Method It is judged an error if no self-addressed communication is sent to the remote controller in a 3-minute period. When a remote controller is set to sub remote controller. •...
  • Page 617 A746802 : 4-way Cassette Type Indoor Unit Control Board EEPROM OPTION TEST Pin CHK Pin A746803 : Duct Type Indoor Unit Control Board EEPROM OPTION TEST Pin CHK Pin A747711 : Ceiling Type (T2 type) Indoor Unit Control Board EEPROM OPTION TEST Pin CHK Pin...
  • Page 618 E02 Remote Controller Transmission Error Error Detection Method When the remote controller itself cannot transmit. Or when it cannot receive the signal it transmitted itself, or when they are different and judged an error. • Malfunction of the remote controller itself (transmit circuit error) Error Diagnosis 1 Remote Is the indoor unit under group control?
  • Page 619 E03 Error in Indoor Unit Receiving Signal from Remote Controller (central) (When indoor unit(s) are connected) Error Detection Method It is judged an error when there is no communication from any remote controller (collectively) in a 3-minute period or if there is no communication from the central device in a 15-minute period.
  • Page 620 A746802 : 4-way Cassette Type Indoor Unit Control Board EEPROM OPTION TEST Pin CHK Pin A746803 : Duct Type Indoor Unit Control Board EEPROM OPTION TEST Pin CHK Pin A747711 : Ceiling Type (T2 type) Indoor Unit Control Board EEPROM OPTION TEST Pin CHK Pin...
  • Page 621 E04 Error in Indoor Unit Receiving Signal from the Outdoor unit Error Detection Method When there is no communication within a 3-minute period from the outdoor unit. Or, judged an error when no reply comes from the outdoor unit. • The outdoor unit is not turned on.
  • Page 622 • Regarding the remote controller check, refer to the Reference Materials. • For information on the procedures for replacing the nonvolatile memory (EEPROM) of the indoor unit and/or replacing the indoor unit’s control board, refer to the manual that is packaged with the indoor unit service board. Outdoor Unit Control PCB CR-50PE1E5 : Up side (U-50PE1E5) A746894 : (U-60PE1E5, U-71PE1E5)
  • Page 623 CR-60PEY1E5 : Up side (U-60PEY1E5) CR-71PEY1E5 : Up side (U-71PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) EEPROM EEPROM TERMINAL TERMINAL A747179 : (U-100PEY1E5) A747180 : (U-125PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) TERMINAL EEPROM TERMINAL...
  • Page 624 A746968 : (U-71PE1E8) A747247 : (U-100PEY1E8, U-125PEY1E8) A746967 : (U-100PE1E8, U-125PE1E8, U-140PE1E8) (for 3-phase outdoor unit PCB) A747596 : (U-140PEY1E8) (for 3-phase outdoor unit PCB) TERMINAL EEPROM TERMINAL EEPROM Indoor Unit Control PCB A746802 : 4-way Cassette Type A746803 : Duct Type EEPROM TEST pin EEPROM...
  • Page 625 E05 Error in Indoor Unit Transmitting Signal to the Outdoor Unit Error Detection Method It is judged an error when a unit itself cannot receive a signal that it has sent. • Indoor unit control PC board error • The setting of the terminal resistor select switch on the outdoor unit main PC board is set incorrectly. Error Diagnosis 1 Indoor Is the indoor/outdoor operation line connected to more than one...
  • Page 626 A746844 : (U-100PE1E5) A746845 : (U-125PE1E5, U-140PE1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) TERMINAL EEPROM TERMINAL EEPROM CR-60PEY1E5 : Up side (U-60PEY1E5) CR-71PEY1E5 : Up side (U-71PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) EEPROM EEPROM TERMINAL...
  • Page 627 A747179 : (U-100PEY1E5) A747180 : (U-125PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) TERMINAL EEPROM TERMINAL EEPROM A746968 : (U-71PE1E8) A747247 : (U-100PEY1E8, U-125PEY1E8) A746967 : (U-100PE1E8, U-125PE1E8, U-140PE1E8) (for 3-phase outdoor unit PCB) A747596 : (U-140PEY1E8) (for 3-phase outdoor unit PCB) TERMINAL EEPROM...
  • Page 628 E06 Outdoor Unit Failed to Receive Serial Communication Signals from Indoor Unit (When indoor unit(s) are connected) Error Detection Method It is judged an error when there is no transmission (reply) from the indoor unit to the outdoor unit for a period of three minutes. •...
  • Page 629 E08 Duplicate Indoor Unit Address Settings Error Error Detection Method It is judged an error if the addresses of indoor units are duplicated. • The indoor unit address settings are duplicated in the remote control detailed settings mode. • The multiple unit DISP pin is shorted across the indoor unit whose address is Not Set. Error Diagnosis Indoor Remove the short...
  • Page 630 E09 More Than One Remote Controller Set to Main Error Error Detection Method It is judged an error when more than one remote controller in a remote control group is set as the main remote controller. Forgot to set one remote controller to sub in a 2-remote control group. •...
  • Page 631 E12Automatic Address Setting Start is Prohibited while Auto-address Setting in Progress. Error Detection Method It is judged an error if a command to start auto address setting comes from another controller during auto address setting. This occurs in a system that has more than one outdoor unit and operating lines among the indoor/outdoor units •...
  • Page 632 E14 Main Unit duplication in Simultaneous-operation Multi Control (detected outdoor unit) Error Detection Method It is judged an error that the main units are duplicated in the indoor unit group. Main unit setting was made in the indoor unit group control setting of the remote control detailed settings mode. •...
  • Page 633 E15 Automatic Address Alarm (The total capacity of indoor units is too low.) Error Detection Method Connecting indoor unit It is judged an error the total capacity of indoor units replied by communication is lower than that of outdoor unit. •...
  • Page 634 E16 Automatic Address Alarm (The total capacity of indoor units is too high.) Error Detection Method It is judged an error the total capacity of indoor units is too high or the total number of indoor units is too many. The total capacity of indoor units is too high.
  • Page 635 E18 Faulty Communication in Group Control Wiring Error Detection Method When the main remote controller cannot communicate with a sub remote controller in the remote control group. It is judged an error if a sub remote controller in a remote control group fails to communicate with the main remote controller for a period of three minutes.
  • Page 636 E20 Connection Problem of Indoor/Outdoor Units Error Detection Method The outdoor unit detects an error at following cases during auto address setting. Indoor unit is not turned On. • Indoor/outdoor control line is disconnected and also detects an error in the following cases when the outdoor unit is •...
  • Page 637 F04 Compressor Discharge Temperature Sensor (TD) Trouble Error Detection Method It is judged an error based on the criteria listed below. Open circuit or Short circuit • Error Diagnosis 1 Sensor Sensor connector is connected to PC board properly. Reconnect and check Replace sensor Correct and see what Sensor is correctly installed at holder side.
  • Page 638 F06 Inlet Temperature Sensor (C1) in Heat Exchanger Trouble Error Detection Method In case of open or short • Error Diagnosis 1 Sensor Is the connector properly connected to PCB? Trouble Reconnect & check Replace sensor. Is the resistor between the sockets infinity or 0Ω? 2 Control Outdoor unit control PCB failure Replace PCB with a new one.
  • Page 639 F07 Intermediate Temperature Sensor (C2) in Heat Exchanger Trouble Error Detection Method It is judged an error when open circuit or short circuit. Error Diagnosis 1 Sensor Sensor connector is connected to PC board properly. Reconnect and check Replace sensor Resistance between sockets is infinity or 0 ohm.
  • Page 640 F08 Outdoor Air Temperature Sensor (TO) Trouble Error Detection Method It is judged an error when open circuit or short circuit. Error Diagnosis 1 Sensor Sensor connector is connected to PC board properly. Reconnect and check Replace sensor Resistance between sockets is infinity or 0 ohm. 2 PC board Replace PC board because of outdoor control PC board failure.
  • Page 641 F12 Compressor inlet Suction Temperature Sensor (TS) Trouble Error Detection Method It is judged an error when open circuit or short circuit. Error Diagnosis 1 Sensor Sensor connector is connected to PC board properly. Reconnect and check Replace sensor Resistance between sockets is infinity or 0 ohm. 2 Outdoor control Replace PC board because of outdoor control PC board failure.
  • Page 642 F31 Outdoor Unit Nonvolatile Memory (EEPROM) Trouble Error Detection Method It is judged an error based on the criteria listed below. When power initially turned ON for the first time, nonvolatile memory (EEPROM) is not installed. • • Read values after writing onto nonvolatile memory (EEPROM) is inconsistent. Error Diagnosis 1 PC board Does EEPROM exist on the control PC board?
  • Page 643 H01 Primary (input) Overcurrent Detected Error Detection Method • Primary current effective value detected overcurrent (trip current value). Trip current value hp = horse power Trip current value hp = horse power Single-phase model 2.5 hp 3 hp 4 hp 5 hp 6 hp 3-phase model...
  • Page 644 A746844 : (U-100PE1E5) A746845 : (U-125PE1E5, U-140PE1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) FUSE1 FUSE1 CR-60PEY1E5 : bottom (U-60PEY1E5) CR-71PEY1E5 : bottom (U-71PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) F001 F001 5-36...
  • Page 645 A747179 : (U-100PEY1E5) A747180 : (U-125PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) FUSE1 FUSE1 A746968 : (U-71PE1E8) A747247 : (U-100PEY1E8, U-125PEY1E8) A746967 : (U-100PE1E8, U-125PE1E8, U-140PE1E8) (for 3-phase outdoor unit PCB) A747596 : (U-140PEY1E8) (for 3-phase outdoor unit PCB) FUSE1 FUSE1 5-37...
  • Page 646 H02 PAM Trouble (Single-phase only) Error Detection Method • Error is detected by over-voltage and overcurrent of DC side. Error Diagnosis Check power supply 1 Power Not satisfied with + 10% rated supply voltage supply* Check power supply Extreme voltage fluctuations Check power supply Extreme distortion of voltage waveform Correct connection...
  • Page 647 H03 Primary Current CT Sensor (current sensor) Failure Error Detection Method It is judged an error based on the criteria listed below. • If 18A or greater is detected when the compressor is stopped (alarm triggered even if the connector is unplugged). •...
  • Page 648 H05 Sensor Failure, Compressor Discharge Temperature Sensor (TD) Disconnected Error Detection Method • (In case of outdoor temperature over 5°C) For 10 minutes since started, variation of discharge temperature is always detected within 2°C comparing with the temperature just before starting. •...
  • Page 649 H31 HIC Trouble Error Detection Method It is judged an error if the computer detects an error signal from the HIC. An error signal is issued by the HIC if abnormal heat occurs inside the HIC or if there is an overcurrent. However, it is judged an error in the same way if the signal line from the HIC is not connected properly or opened.
  • Page 650 Tester terminals HIC- HIC+ Resistance value (ohm) 1 k to 10 k 1 k to 10 k 1 k to 10 k 5 k to 20 k 20 k to 20 k to 20 k to 20 k to Tester terminals Resistance value (ohm) 20 k to 20 k to...
  • Page 651 Outdoor Unit Control HIC PCB A746846 : (U-100PE1E5) A746847 : (U-125PE1E5, U-140PE1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit HIC PCB) Outdoor Unit Control PCB CR-60PEY1E5 : bottom (U-60PEY1E5) CR-71PEY1E5 : bottom (U-71PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) 5-43...
  • Page 652 A746846 : (U-100PEY1E5) A746847 : (U-125PEY1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit HIC PCB) A746970 : (U-71PE1E8) A747248 : (U-100PEY1E8, U-125PEY1E8) A746969 : (U-100PE1E8, U-125PE1E8, (for 3-phase outdoor unit HIC PCB) U-140PE1E8, U-140PEY1E8) (for 3-phase outdoor unit HIC PCB) Outdoor Unit Control PCB A746968 : (U-71PE1E8) A747247 : (U-100PEY1E8, U-125PEY1E8)
  • Page 653 L04 Outdoor Unit Address Duplication Error Detection Method It is judged an error when the identical self-address communication on the indoor and outdoor wirings is received over 5 times within 3 minutes. Error Diagnosis 1 System Are other outdoor units using a duplicate setting? address Installation When units are networked, first set the system address for each outdoor unit in the order...
  • Page 654 L10 Outdoor Unit Capacity not Set or Invalid Error Detection Method It is judged an error when outdoor unit capacity not yet setup or systematically unauthorized setting. Error Diagnosis 1 Check the Was EEPROM replaced when PC board was replaced? control Replace EEPROM PC board...
  • Page 655 L13 Indoor Unit Type Setting Error Error Detection method • Discordance model(s) between outdoor and indoor units are detected. 1 Discordance Are models for outdoor and indoor units matched respectively? Unit (Ex: Are multiple indoor units connected to commercial outdoor units?) Replace indoor units.
  • Page 656 L18 4-way Valve Operation Failure Error Detection Method It is judged an error when during heating operation (Comp. ON), the highest detected temperature at an outdoor unit heat exchanger (C1) was 20°C or more above the outdoor air temperature (Air Temp.) continuously for 5 minutes or longer.
  • Page 657 P03 Compressor Discharge Temperature Trouble Error Detection Method • When the discharge temperature is over 106°C. Error Diagnosis Additional 1 Adjustment refrigerant charge Not additional refrigerant charged refrigerant charge Adjust the refrigerant amount Tends to have insufficient refrigerant charge in the system. Replace CR board 2 Blockage in Open service valve...
  • Page 658 P04 High Pressure Trouble Error Detection Method It is judged an error if the internal circuit of the high pressure switch is dead. The electronic circuitry of the high pressure switch is cut off if the pressure at the pressure sensor port of the high pressure switch reaches 3.80 MPa.
  • Page 659 3 Problem Prevent air short The intake temperature (ambient temperature) of the indoor unit is around the circuit above 36°C. heat exchanger Clean the filter The filter of the indoor unit is clogged. Replace the indoor fan (motor) The fan of the indoor unit is broken or the fan motor is faulty. 4 Blockage Is the outdoor unit’s electronic control valve operating correctly? in the...
  • Page 660 P05 AC Power Supply Trouble Error Detection Method • Instantaneous blackout • Zero-cross (waveform input of power supply) error • DC voltage charge failure Error Diagnosis Note : The work involved in diagnosing each of the items is extremely dangerous, so turn the power off at the breaker before performing the tests.
  • Page 661 P13 Alarm Valve Open Error Detection Method Detection is performed only in the test run. When once detected or the test run finished without any error, the second detection will not be done. In case of forgetting to open a valve, P04 (high-pressure switch operational alarm) is occasionally preceded due to the following conditions.
  • Page 662 P14 O Sensor Detect Error Detection Method • It is judged an error whenever the outdoor unit receives the signal “O Alarm Occurred” from the indoor unit. • With the indoor unit’s EEPROM setting (item code 0B) set to 0001, the EXCT input was shorted. Error Diagnosis 1 System Is an O...
  • Page 663 P15 Insufficient Gas Level Detected Abnormal Detection Method Alarm occurs in the following cases: • Compressor's current value shows lower than a certain value. • Compressor's discharge temperature exceeds 95°C. • Electronic expansion valve is fully opened. • The difference between indoor unit heat exchanger temperature and intake temperature is less than 4K. Error Diagnosis 1 Adjustment Recharge with...
  • Page 664 P16 Compressor Overcurrent Trouble Meaning of Alarm • Secondary current effective value detected the overcurrent (trip current value). Single-phase model (2.5hp – 3hp) : Trip current = 23.0 A 3-phase model (4hp – 6hp) : Trip current = 17.0 A Single-phase model (4hp –...
  • Page 665 4 Check the Take measures Outdoor air intake temperature is high. situation Correct May be caused by poor outdoor unit air flow (dirty or clogged heat exchanger, blocked discharge port, etc.) Prevent air short Air short circuit has occurred. This is a phenomenon when circuit discharged air (exhaust heat) from the outdoor unit is drawn back into the suction vent.
  • Page 666 9 Check the See what happens. Replace the HIC PC board and operate the unit. (Apply putty and HIC PC screws must not be loose) Does it operate normally? 10-1 boards 10 Check the outdoor 10-1 Replace the control PC board and operate the unit. See what happens.
  • Page 667 Outdoor Unit Control HIC PCB Outdoor Unit Control PCB A746895 : (U-60PE1E5, U-71PE1E5) CR-50PE1E5 : bottom (U-50PE1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit PCB) Outdoor Unit Control HIC PCB A746846 : (U-100PE1E5) A746847 : (U-125PE1E5, U-140PE1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit HIC PCB) 5-59...
  • Page 668 Outdoor Unit Control PCB CR-60PEY1E5 : bottom (U-60PEY1E5) CR-71PEY1E5 : bottom (U-71PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) Outdoor Unit Control HIC PCB A746846 : (U-100PEY1E5) A746847 : (U-125PEY1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit HIC PCB) 5-60...
  • Page 669 Outdoor Unit Control HIC PCB A746970 : (U-71PE1E8) A747248 : (U-100PEY1E8, U-125PEY1E8) A746969 : (U-100PE1E8, U-125PE1E8, (for 3-phase outdoor unit HIC PCB) U-140PE1E8, U-140PEY1E8) (for 3-phase outdoor unit HIC PCB) 5-61...
  • Page 670 P22 Outdoor Unit Fan Motor Trouble Error Detection Method • It is judged an error when the outdoor fan motor’s rotating signal cannot be detected normally. Error Diagnosis 1 Wiring Are the connectors “CN-FMA”, “CN-FMB”, “CN-FM1”, and “CN-FM2” firmly connected to the outdoor control PC board Correct the connector (lock engaged)? connections...
  • Page 671 P29 Lack of INV compressor wiring, INV compressor actuation failure (including locked), DCCT failure Error Detection Method • Abnormal current is detected at DCCT before start-up. • Start-up failed during overcurrent and/or step-out detected. • Open-wire of compressor and/or backspin detected. •...
  • Page 672 P31 Group Control Error Error Detection Method • Other indoor unit alarms within the group. 1 Other indoor Survey the indoor unit that alarms other than “P31” in the indoor unit group and specify the unit causes of failure. 5-64...
  • Page 673 Outdoor Unit Control HIC PCB Outdoor Unit Control PCB A746895 : (U-60PE1E5, U-71PE1E5) CR-50PE1E5 : bottom (U-50PE1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit PCB) Outdoor Unit Control HIC PCB A746846 : (U-100PE1E5) A746847 : (U-125PE1E5, U-140PE1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit HIC PCB) 5-65...
  • Page 674 Outdoor Unit Control PCB CR-60PEY1E5 : bottom (U-60PEY1E5) CR-71PEY1E5 : bottom (U-71PEY1E5) (for single-phase outdoor unit PCB) (for single-phase outdoor unit PCB) Outdoor Unit Control HIC PCB A746846 : (U-100PEY1E5) A746847 : (U-125PEY1E5) (for single-phase outdoor unit HIC PCB) (for single-phase outdoor unit HIC PCB) 5-66...
  • Page 675 Outdoor Unit Control HIC PCB A746970 : (U-71PE1E8) A747248 : (U-100PEY1E8, U-125PEY1E8) A746969 : (U-100PE1E8, U-125PE1E8, (for 3-phase outdoor unit HIC PCB) U-140PE1E8, U-140PEY1E8) (for 3-phase outdoor unit HIC PCB) 5-67...
  • Page 676: Inspection Of Parts (Outdoor Unit)

    5-4. Inspection of Parts (Outdoor Unit) (1) Electronic control valve (MOV1) MOV1: Measure the voltage between plug pin 5 and pins 1 through 4 at the CN-MOV1 connector (5P, white) on the outdoor unit control PCB. (Because of the pulse output, a simplified measurement method is used. Set the tester to the 12 V range;...
  • Page 677: Symptom: Thermostat In Off Continues Or Cycles Off & On Too Frequently

    5-5. Symptom: Thermostat in OFF continues or cycles OFF & ON too frequently How to detect abnormality • Abnormality does not occur. Protective function can be checked when the outdoor maintenance remote controller is connected. Error Diagnosis Adjust setting Indoor control Setting temperature reaches the level set ON thermostat.
  • Page 678: How To Clean Heat Exchanger

    5-6. How to Clean Heat Exchanger Turn off the power supply. WARNING ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. Remove the lid (drain pump). (Fig. 1) Drain plug Fig. 1 Remove the drain plug and drain the water from the drain pan. (Fig. 1) Insert a high pressure cleaner from the opening (Fig.
  • Page 679: How To Replace Fan Motor

    5-7. How to Replace Fan Motor Removing Fan Motor Turn off the power supply. Screws x 5 locations WARNING Lid of electrical ELECTRICAL SHOCK CAN CAUSE component box SEVERE PERSONAL INJURY OR DEATH. Fig. 1 Remove the lid of the electrical component box. (Screws x 5 locations: Fig.
  • Page 680 6. Remove the screws (M6 x2 locations: Fig. 6) fixing the fan motor. It is recommended that a nutdriver (8mm) be used. Bracket Screws (M6) Fig. 6 7. Remove the bracket (Fig. 6) and then remove the fan and fan motor (Fig. 7). Fan motor Fig.
  • Page 681: Section 6. Outdoor Unit Maintenance Remote Control

    6. OUTDOOR UNIT MAINTENANCE REMOTE CONTROL 6-1. Overview ........................6-2 6-2. Functions ........................6-2 6-3. Normal Display Operations and Functions ............6-3 6-4. Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor Temperatures ......................6-6 6-5. Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit Alarm History ........................
  • Page 682: Overview

    6-1. Overview What is the outdoor unit maintenance remote controller? Beginning with the DC-INV series of outdoor units, nonvolatile memory (EEPROM) is used in the outdoor unit PCB. In this way, the setting switches that were located on earlier PCBs have been converted to EEPROM data. This remote controller is an out- door unit maintenance tool that is used to make and change the EEPROM settings.
  • Page 683: Normal Display Operations And Functions

    Temperature monitor • Displays the indoor/outdoor unit sensor temperatures. Outdoor unit alarm history monitor • Displays the outdoor unit alarm history. Setting modes • Setting mode 1 and setting mode 2 are used to make the outdoor EEPROM setting. 6-3. Normal Display Operations and Functions Normal display functions •...
  • Page 684 Display (functions) • Use the temperature setting buttons to change the item code. 00(1) Outdoor unit contents (code) : OFF when normal At initial status Blinking 8 - alarm code display at pre-trip,LED (2) No. of indoor units connected in that refrigerant system Unit Nos.
  • Page 685 *2: 7-segment, 4-digit display for remote controller timer display The connected unit Nos. are displayed as shown below, using the 7-segment 4-digit ( ) display and the colon. Display for unit Nos. 1 – 20 Not lit Not lit Not lit Not lit Meaning of display colon —...
  • Page 686: Monitoring Operations: Display Of Indoor Unit And Outdoor Unit Sensor Temperatures

    6-4. Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor Temperatures <Operating procedure> (1) Press and hold the button and button simultaneously for 4 seconds or longer to switch to temperature monitor mode. During temperature monitoring, “Service Monitor” is lit. (The display and operations are the same as when monitor mode is started from the unit remote controller.) (2) Press...
  • Page 687: Monitoring The Outdoor Unit Alarm History: Display Of Outdoor Unit Alarm History

    6-5. Monitoring the Outdoor Unit Alarm History: Display of Outdoor Unit Alarm History Displays outdoor unit alarms only. Does not display indoor unit alarms. Check the indoor unit alarm histories separately using the indoor unit remote controllers or other control device. <Operating procedure>...
  • Page 688 List of Item Codes (Some item codes cannot be set due to the type of models.) Silent level 1=Silent level1 2=Silent level2 3=Silent level3 Ignore capacity 0 = Disabled 1 = Ignores capacity ratio Forced operation of 0 = Disable 1 = 2 hours stopped + 20 minutes operating indoor unit drain pump (regardless of whether the unit is running or stopped)
  • Page 689: Section 7. Remote Controller Functions Section

    7. REMOTE CONTROLLER FUNCTIONS SECTION 7-1. Simple Settings Function ..................7-2 7-2. List of Simple Setting Items ..................7-3 7-3. Detailed Settings Function ..................7-4 7-4. List of Detailed Setting Items .................. 7-5 7-5. Simple Setting Items ....................7-9 7-6. Detaild Setting Items ....................
  • Page 690: Simple Settings Function

    7-1. Simple Settings Function • This allows the filter lifetime, operating mode priority change, central control address, and other settings to be made for an individual or group- control indoor unit to which the remote controller used for simple settings is connected. When simple settings mode is engaged, operation stops at the individual or group-control indoor unit to which the remote controller for simple settings is...
  • Page 691: List Of Simple Setting Items

    7-2. List of Simple Setting Items Setting data Item code Item Description 0000 Not displayed 0001 150 hours Filter sign ON time 0002 2,500 hours (filter life time) 0003 5,000 hours 0004 10,000 hours 0005 Use the filter clogging sensor. 0000 Standard (setting at time of shipping) Degree of filter fouling Highly fouled...
  • Page 692: Detailed Settings Function

    7-3. Detailed Settings Function • This allows the system address, indoor unit address, and other settings to be made for the individual or group-control indoor unit to which the remote controller used for detailed settings is connected. When detailed settings mode is engaged, operation stops at the individual or group-control indoor unit where the remote controller used for detailed settings is connected.
  • Page 693: List Of Detailed Setting Items

    7-4. List of Detailed Setting Items Setting data Item Item code Description Description 4-Way Cassette (U1) Low Silhouette Ducted (F1) 0001 0005 4-Way Cassette 60 x 60 (Y1) Ducted (N1) Type High Static Pressure Ducted (E1) 0007 Ceiling (T1) (T2) 0006 Wall mounted (K1) 0008...
  • Page 694 Setting data Item code Item Forced thermostat ON 0000 5 minutes (1B) time 0001 4 minutes 0001 ± 1°C 0002 ± 2°C Temperature shift for 0003 ± 3°C cooling/heating change in auto heat/cool mode 0007 ± 7°C 0018 18°C (Lower limit at shipment) 0019 19°C (Upper limit)
  • Page 695 Setting data Item code Item Description 0000 No forced operation 0001 Forced operation for 1 minute Automatic drain pump operation Continuous operation 0060 None 0000 Ventilation fan operation 0001 Ventilation fan operated by remote controller. 0000 Not used. (Body sensor is used.) Wired remote controller Remote control sensor is used.
  • Page 696 Setting data Item code Item Description DC fan tap Purpose operating mode 0000 Standard Standard (setting at shipment) High ceiling use High ceiling setting 1 (with standard panel) Ultra long-life filter, oil guard panel, ammonia 0001 For low static- deodorizing filter, optical regenerative pressure filter Fan tap setting deodorizing filter...
  • Page 697: Simple Setting Items

    7-5. Simple Setting Items Item code Item Description Filter sign ON time setting Changes the indoor unit filter lifetime when a high-performance filter or (filter lifetime) other optional product is installed. Reduces the filter sign ON time to 1/2 of the standard time (setting at the Degree of filter fouling time of shipping) for cases when filter fouling is more severe than normal.
  • Page 698 When the operating mode at the priority remote controller is changed, the operating modes of other remote controllers change as shown below. Mode change at priority remote controller Operating modes at other remote controllers Current mode New mode Current mode New mode Cooling or dry Heating...
  • Page 699: Detaild Setting Items

    7-6. Detaild Setting Items Item code Item Description Unit type Set when the indoor unit EEPROM memory is replaced during servicing. Indoor unit capacity System (outdoor unit) These are not set at the time of shipping from the factory. address These must be set after installation if automatic address setting is not Indoor unit address performed.
  • Page 700 Item code Item Description 1F (Upper limit) Cooling 20 (Lower limit) This setting changes the temperature range (upper limit and lower 21 (Upper limit) Change to the Heating limit) which is set from the remote controller or central control device. 22 (Lower limit) remote control The set upper limit must be greater than or equal to the lower limit.
  • Page 701 (Continued from previous page) Item code Item Description Heat exchanger The heat exchanger temperature control point for prevention of cold temperature for cold air air discharge during heating operation can be changed. discharge The indoor unit PCB optional output for the fan can be switched Fan output switching according to the purpose of use.
  • Page 702 DC Fan Tap Change Procedure <Procedure> Be sure to turn the main power OFF before performing the steps below. (1) Check the optional product that will be used from the table below. Setting No. Optional part name Optional part No. Air-blocking material (for 3-direction discharge) CZ-CFU2 Air-blocking material (when a discharge duct is connected) CZ-CFU2...
  • Page 703: Remote Controller Servicing Functions

    7-7. Remote Controller Servicing Functions • The remote controller includes a number of servicing functions. Use these as needed for test runs and inspections. List of Servicing Functions Functions Description Button operation Reset operation Unit status Operation with forced Press and hold the button for 4 Test run thermostat ON...
  • Page 704 Sensor Temperature Display Function (displayed regardless of whether unit is operating or stopped) The procedure below displays the sensor temperatures from the remote controller, indoor unit, and outdoor unit on the remote controller. <Procedure> 1 Press and hold the buttons simultaneously for 4 seconds or longer.
  • Page 705: Section 8. How To Install The Wireless Remote Controller Receiver

    8. HOW TO INSTALL THE WIRELESS REMOTE CONTROLLER RECEIVER Important Safety Instructions ..................8-2 Optional Controller (Remote Controller) ................ 8-1. Names and Functions ....................8-2. Installing Batteries ....................8-5 8-3. Setting the Current Time ..................8-4. Operation .........................8-6 8-5. Timer Operation ....................... 8-7 8-6.
  • Page 706: Important Safety Instructions

    Important Safety Instructions Warning Installation Precautions • Do not install yourself Installation should always be performed by your dealer or a professional service provider. Electric shock or fire may result if an inexperienced person performs any installation or wiring procedures incorrectly.
  • Page 707: Optional Controller (Remote Controller)

    Optional Controller (Remote Controller) Wireless Remote Controller CZ-RWSU2 / CZ-RWST2 / CZ-RWSL2 / CZ-RWSC2 / CZ-RWSY2 / CZ-RWSK2 / CZ-RWST3 One remote control can control a group of up to eight indoor units. 8-1. Names and Functions REMOTE CONTROL Use this when switching to detect Displays the operation status.
  • Page 708 RECEIVER CZ-RWSU2 CZ-RWST2 1. Receiver Receives the signal sent from the remote control. 2. Emergency Display lamps operation button When an error occurs, one of the lamps flashes. When a display lamp is blinking, refer to " Before 3 4 5 Requesting Service ".
  • Page 709: Installing Batteries

    8-2. Installing Batteries 1. Remove the cover. 2. Insert two AAA alkaline batteries. Put the batteries in with the polarity [+/–] as shown in the figure. 3. Gently insert one end of an unfolded paper clip (or a similar object that can fit) into the Reset hole and press the Reset button inside the hole and then put the cover back on.
  • Page 710: Operation

    8- 4. Operation , Dry , Cool , Fan Auto , Heat Models that only provide the cooling function cannot operate in the auto or heating modes. Power: Turn on the power of the indoor unit at least 14 hours before operation. 1.
  • Page 711: Timer Operation

    8-5. Timer Operation When setting the timer, make sure the current time on the remote control is accurate. The timer’s clock can only be set when the display of the remote control is ON. After setting the timer, put the remote control in a place where its signal will reach the receiver of the indoor unit.
  • Page 712: Adjusting The Wind Direction

    8-6. Adjusting the Wind Direction Never try to manually move the flap (up-down wind direction plate) that is operated by the remote control. When the unit stops, the flap (up-down wind direction plate) automatically faces downwards. When the unit is in heating standby, the flap (up-down wind direction plate) faces upward. Also, bear in mind that the flap starts swinging after the heating standby mode is released, but the display on the remote control indicates Auto Flap during standby heating as well.
  • Page 713: Using The Remote Control

    8-8. Using the Remote Control Point the transmitter of the remote control at the receiver. When the signal is received correctly it will beep once. (It beeps twice only when the unit starts operating.) The signal can be received at a distance of about 6 meters. This distance should be used only as a guide. It depends on battery strength.
  • Page 714 Matching up Addresses Setting Remote Control Addresses 1. If you press at the same time , “ ” will blink. 2. While holding down, every time you press , it cycles from ALL 3… ALL. Set it to the receiver address switch of the indoor unit you wish to operate. 3.
  • Page 715: Emergency Operation

    8-11. Emergency Operation Use [Emergency Operation] in the following situations when there is an urgent need. When the remote control’s batteries have failed. When the remote control is broken. When the remote control is lost. Figures: CZ-RWSU2, CZ-WRSY2, CZ-RWST2 and CZ-RWST3 are of receivers (inside indoor unit), CZ-RWSL2 is of the operation panel (inside indoor unit) and Indoor Unit (CZ-RWSK2) is of its front panel.
  • Page 716: Miscellaneous Settings

    8-12. Miscellaneous Settings A variety of changes can be made to settings, depending on the indoor unit being used. Operation mode indicator, time display (24 hour, AM/PM), Heat Max Temp (These settings are saved in nonvolatile memory in the remote control, so even when its batteries are changed, the settings do not have to be made again.) First check the display of the remote control when the unit is stopped and then make any desired settings.
  • Page 717: Before Requesting Service

    8-13. Before Requesting Service Before requesting service, please check the followings. Problem Cause Solution The power to the indoor unit is not ON. Make sure the power to the indoor unit is ON. The unit doesn’t work even when is pressed on the Is the Normal/Stop All switch in the Stop All Switch it to the Normal position and cancel remote control.
  • Page 718: How To Install The Wireless Remote Controller Receiver

    How to Install the Wireless Remote Controller Receiver 8-14. Common to All Models 1. Warnings about Installation of Receivers The wireless remote uses a very weak infrared light for its signal, which can result in the signal not being received because of the following influences, so take care in where the unit is installed.
  • Page 719 CZ-RWSU2 S003 → Bit 1: OFF Screw Cable clamp Receiver PCB PCB cover Adjustable Corner Cap CZ-RWST2 • CZ-RWST3 CZ-RWSL2 DIP Switch 3 S003 → Bit 3: OFF CZ-RWSC2 RCU: MAIN → RCU: SUB 8-15...
  • Page 720: Cz-Rwsu2

    8-15. CZ-RWSU2 1. Accessories Accessories Quantity Accessories Quantity Dry-cell Batteries Receiver Users Manual 6 Truss Self-Tapping Screws 4 X 16 Remote Control Cable clamp Remote Control Holder 2. Installing the Receiver The receiver can only be installed on the corner indicated in Fig. 8-1, so consider how the panel will face when it is installed on the indoor unit.
  • Page 721 3. Wiring the Receiver Wiring Diagram Indoor Unit Receiver PCB Terminal Strip for White Wiring Remote Black Controls Connections Connect the wires from the receiver to the remote control terminal strip on the indoor unit. (Polarity does not matter) 4. Test Operation CZ-RWSU2 Implementing a Test Run S003...
  • Page 722: Cz-Rwst2

    8-16. CZ-RWST2 1. Accessories Accessories Quantity Accessories Quantity Receiver Dry-cell Batteries Users Manual Remote Control Truss Self-Tapping Screws 4 X 16 Cable tie Remote Control Holder 2. Installing the Receiver Ceiling Suspended Model (1) Open the air inlet grill on the side panel, remove the 1 screw and then move it toward the front (direction of the arrow) and remove it.
  • Page 723 Unidirectional cassette model for high ceilings/Unidirectional ceiling cassette model (1) While spreading the tabs of the cover, pull it out from the panel to the front. (Fig. 8-10) (2) Pass the lead wire through the panel and install the receiver in the hole in the panel. (The projecting parts of the receiver hold it in the hole in the panel) (3) Press the lead wire from the receiver in along the rib on the back of the panel.
  • Page 724 4. Test Operation Implementing a Test Run 1. Turn the #1 DIP switch [S003] on the receiver’s PCB from OFF to ON and operate the wireless remote control with its Start/Stop button. 2. During a test run, all display lamps on the display will light up. 3.
  • Page 725: Cz-Rwsl2

    8-17. CZ-RWSL2 1. Accessories Accessories Quantity Accessories Quantity Operation Panel Dry-cell Batteries Users Manual Display Truss Self-Tapping Screws 4 X 16 Pan Head Self-Tapping Screws Remote Control 4 X 10 Plastic Clamp L150 Installing the Display/Operation Panel Resin Panel Installing the Operation Panel Remove the 2 screws and remove cover A from the back of the panel.
  • Page 726 Metal Panel Installing the Operation Panel Remove the 2 screws and remove cover A from the back of the panel. (Fig. 8-19) Fasten the operation panel to the location in the diagram below with the 2 enclosed screws (4 10). (Fig. 8-20) Pass the wiring for the display (W2, 6P white connector) through the back of the panel.
  • Page 727 4. Test Operation Implementing a Test Run 1. Turn the #1 DIP switch of the operation panel from OFF to ON (Down Up) and operate the wireless remote control with its Start/Stop button. 2. During a test run, all display lamps on the display will light up. 3.
  • Page 728: Cz-Rwsc2

    8-18. CZ-RWSC2 1. Accessories Accessories Quantity Accessories Quantity Receiver Users Manual (Enclosed 200 mm wiring) Truss Self-Tapping Screws 4 X 16 Remote Control Small screw Remote Control Holder Wood screw Dry-cell Batteries Cable tie 2. Installing the Receiver When using a separately installed receiver as a built-in model, install it to the JIS switch box (field supply) shown in the diagram on the right, which has been built into the wall on site in advance.
  • Page 729 When using a separately installed receiver as an exposed model, attach it to a wall where the receiver can be affixed. (1) Put a slotted screwdriver or the like into the groove on the bottom of the receiver unit and twist it to remove the bottom of the case.
  • Page 730 When using a receiver that has been installed separately into the ceiling, use the enclosed fittings for installing to a ceiling. Part A Part B Fig. 8-29 Fig. 8-31 Fig. 8-30 (1) Remove the metal plate of the receiver by slipping a slotted screwdriver or the like into the cutout on the bottom. (2) Cut out a hole in the ceiling to match the dimensions of the enclosed template.
  • Page 731 If it is to be used as an exposed model: Wiring Diagram Terminal strip for wiring White the remote control of the Black indoor unit Receiver Remote Control Cord (Sold Separately) Use remote control cord (sold separately) for wiring a separately installed receiver. (1) For instructions on how to install a remote control cord (sold separately), refer to the chapter on Using as an Embedded Model in Installing Separate Receivers.
  • Page 732: Cz-Rwsy2

    8-19. CZ-RWSY2 1. Accessories Accessories Quantity Accessories Quantity Receiver Remote Control Holder AAA alkaline batteries Tapping screw 4x16 Clamper Remote Controller 2. Installing the Receiver Unit As the receiver can only be installed in the corner where the panel wire comes out, as shown in Fig. 8-32, consideration should be given to orientation when fitting the panel to the indoor unit.
  • Page 733 3. Pass the wire from the wireless receiver through the grille. (Fig. 8-34) 4. Fit the panel to the indoor unit and connect the wire from the receiver to the connector (CN130/WL/WHT/10P) on the indoor control board. (Fig. 8-35) 5. After fixing the panel in place, fit the receiver to the panel taking care not to trap the wire from the receiver. 6.
  • Page 734: Cz-Rwst3

    8-20. CZ-RWST3 1. Accessories Accessories Quantity Accessories Quantity Dry-cell Batteries Receiver Users Manual Truss Self-Tapping Screws Remote Control 4 × 16 Remote Control Holder Cable tie 2. Installing the Receiver Ceiling Suspended Model Remove the screw, and slide the latch to open the air-intake grille. (Fig. 8-36) Insert a flat-head screwdriver from the side, and remove the cover while pressing down on the two cover tabs.
  • Page 735 Removing and Mounting the Side Cover Removing the side cover Side cover Remove the side cover mounting screw, and slide the side cover to the front side (direction of arrow in Fig. 8-41) to remove. Mounting the side cover Slide in the side cover from the indoor unit front side, mount to the latch tabs, and secure using the side cover mounting screw.
  • Page 736: Common To All Models

    8-21. Common to All Models 1. The Self-Diagnosis Function Display and What is Detected Alarm Display in the table below indicates the content of alarms that are displayed when a wired remote control is connected. For information on how to deal with the alarms, refer to the Mounting Instructions for the indoor unit or to Test Run or servicing materials.
  • Page 737 3. Setting Up Remote Control Functions The functions of the wireless remote can be set on site. (These settings are saved in nonvolatile memory in the remote control, so even when its batteries are changed, the settings do not revert to the defaults.) NOTE The operation of the air conditioner can be impacted, depending on the settings made, so only service personnel should make the settings.
  • Page 738 – MEMO – 8-34...
  • Page 739 201309...

Table of Contents