SiBE12-713
6.1.11 Capacitor Voltage Check
Check No.12
Before this checking, be sure to check the main circuit for short-circuit.

6.1.12 Power Transistor Check

Check No.13
Tester's negative terminal Power transistor
Tester's positive terminal
Normal resistance
Abnormal resistance
Service Diagnosis
Checking the capacitor voltage
With the circuit breaker still on, measure the voltage according to the drawing of the model in
question. Be careful never to touch any live parts.
MULTIMETER
(DC. VOLTAGE RANGE)
FAN MOTOR LEAD WIRE
ELECTRONIC EXPANSION VALVE
COIL LEAD WIRE(ROOM-A)
Checking the power transistor
Never touch any live parts for at least 10 minutes after turning off the circuit breaker.
If unavoidably necessary to touch a live part, make sure the power transistor's supply
voltage is below 50 V using the tester.
For the UVW, make measurements at the Faston terminal on the board or the relay
connector.
REACTOR LEAD WIRE
ELECTRONIC EXPANSION VALVE
ELECTRONIC EXPANSION VALVE COIL
COIL LEAD WIRE(ROOM-C)
LEAD WIRE(ROOM-B)
UVW
(+)
Power transistor
UVW
(+)
Several kohms to several Mohms
COMPRESSOR LEAD WIRE
OL LEAD WIRE
THERMISTOR LEAD WIRE
THERMISTOR LEAD WIRE
(GAS PIPE)
THERMISTOR LEAD WIRE
(LIQUID PIPE)
REVERSING SOLENOID
VALVE LEAD WIRE
Power transistor
(–)
Power transistor
UVW
0 or ∞
Check
(R5154)
UVW
(–)
283