Step
8
Disconnect the
connector for overload
protector [S40].
9
Remove the OL wire
harness and the
compressor wire
harness together from
the partition plate.
10 Use long-nose pliers or
the like to pull out the
clamp.
Disconnect the
11
connector for relay
harness of compressor.
Removal Procedure
Procedure
Clamp
(R6422)
Detach the clamp.
Just pull the push-mount
type out of position.
Clamp
(R6423)
Outdoor Unit
Points