Wiring Diagrams; Indoor Units - Daikin F-Series Service Manual

Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

SiBE12-713
2.

Wiring Diagrams

2.1

Indoor Units

2.1.1 Wall Mounted Type
FTKS20D3VMW(L), FTKS25D3VMW(L), FTKS35D3VMW(L)
FTXS20D3VMW(L), FTXS25D3VMW(L), FTXS35D3VMW(L)
PCB3
S27
S26
LED1
H1P
LED2
H2P
LED3
H3P
S1W
S21
R1T
PCB4
S35
S36
INTELLIGENT EYE
SENSOR
PCB2
WIRELESS
REMOTE
RECEIVER
CONTROLLER
FTKS50D2V1W(L), FTXS50D2V1W(L)
PCB3
S27
S26
LED1
H1P
LED2
H2P
LED3
H3P
S1W
S21
HA
R1T
PCB4
S36
S35
INTELLIGENT EYE
SENSOR
PCB2
WIRELESS
REMOTE
RECEIVER
CONTROLLER
Appendix
PCB1
RECTIFIER
V1
TRANSMISSION
HA
S28
S32
1
S6
5
S29
R2T
SIGNAL
M
M1S
PCB1
~
~
RECTIFIER
V1
TRANSMISSION
S28
S32
1
S6
X41A
S29
SIGNAL
M
R2T
M1S
F1U
H1
3.15A
H2
H3
GRN
CIRCUIT
FG
S1
7
RED
BLU
FG
BRN
M
F1U
ORG
H1P~H3P
1
WHT
M1F
M1F
M1S
PCB1~PCB4
R1T, R2T
S1~S38
S1W
X1M
INDOOR
F1U
H1
3.15A
H2
H3
CIRCUIT
FG
S1
7
RED
BLU
BRN
M
ORG
1
WHT
M1F
5
INDOOR

Wiring Diagrams

FIELD WIRING.
1
X1M
2
BLK
1
3
WHT
2
RED
3
CAUTION
/
YLW
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
: FRAME GROUND
: FUSE
: PILOT LAMP
: FAN MOTOR
: SWING MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: TERMINAL STRIP
: PROTECTIVE EARTH
FIELD WIRING.
X1M
BLK
1
WHT
2
3
RED
GRN
/
YLW
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
FG
: FRAME GROUND
F1U
: FUSE
H1P~H3P
: PILOT LAMP
M1F
: FAN MOTOR
M1S
: SWING MOTOR
PCB1~PCB4
: PRINTED CIRCUIT BOARD
R1T, R2T
: THERMISTOR
S1~S38, X41A
: CONNECTOR
S1W
: OPERATION SWITCH
X1M
: TERMINAL STRIP
: PROTECTIVE EARTH
OUTDOOR
3D051268A
1
2
3
OUTDOOR
CAUTION
3D051652