Wiring Diagrams
FTKS20CAVMB, FTKS25CAVMB, FTKS35CAVMB
FTXS20CAVMB, FTXS25CAVMB, FTXS35CAVMB
PCB3
S36 S35
INTELLIGENT-
EYE SENSOR
S27
S26
PCB2
LED1
LED2
LED3
S21
H1P
H2P
H3P
S1W
SIGNAL
RECEIVER
S32
R1T
R2T
WIRELESS
REMOTE
CONTROLLER
FTKS50FV1B, FTKS60FV1B, FTKS71FV1B
FTXS50FV1B, FTXS60FV1B, FTXS71FV1B
PCB3
S27
S26
t
°
R1T
S38
PCB4
S37
S21
LED1
LED2
LED3
H1P
H2P
H3P
PCB5
S36
S35
INTELLIGENT EYE
SENSOR
PCB2
SIGNAL
RECEIVER
WIRELESS
S1W
REMOTE
CONTROLLER
332
PCB1
(
TERMINAL FOR
)
CENTRALIZED CONTROL
S1
S7
M
S6
1
°
t
M
indoor
M1S
:
PROTECTIVE EARTH
C70
:
RUNNING CAPACITOR
:
FU
FUSE
PCB1
~
~
RECTIFIER
TRANSMISSION
S28
S32
1
S6
5
1
S29
R2T
M
M1S
H1
Fu
3.15A
H2
C70
H3
TRANSMISSION
CIRCUIT
°
140
C
H1P~H3P
M1F
M1F
M1S
PCB1~PCB3 : PRINTED CIRCUIT BOARD
R1T~R2T
S1~S36
S1W
X1M
H1
Fu
3.15A
H2
H3
CIRCUIT
FG
S1
7
RED
M
BLU
BRN
ORG
M1F
1
WHT
S8
6
INDOOR
M
M2S
X1M
1
BLK
WHT
2
RED
3
/
GRN
FIELD WIRING.
YLW
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
: PILOT LAMP
: FAN MOTOR
: SWING MOTOR
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: TERMINAL STRIP
FIELD WIRING.
X1M
BLK
1
WHT
2
RED
3
GRN
CAUTION
/
YLW
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
FG
: FRAME GROUND
Fu
: FUSE
H1 ~ H3
: HARNESS
H1P ~ H3P
: PILOT LAMP
M1F
: FAN MOTOR
M1S, M2S
: SWING MOTOR
PCB1~ PCB5
: PRINTED CIRCUIT BOARD
R1T, R2T
: THERMISTOR
S1 ~ S38
: CONNECTOR
S1W
: OPERATION SWITCH
X1M
: TERMINAL STRIP
: PROTECTIVE EARTH
SiBE12-713
1
2
3
outdoor
3D033599G
1
2
3
OUTDOOR
3D038530N
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents