Step
3. Remove the liquid/gas
pipe thermistor
1
Open the putty and
remove the liquid pipe
thermistor.
[S90] :
Outdoor air
thermistor
Heat exchanger
thermistor
Discharge pipe
thermistor
[S92] :
Gas pipe
thermistor
Room A (Black)
Room B (Gray)
Room C (Brown)
Room D (Red)
[S93] :
Liquid pipe
thermistor
Room A (Black)
Room B (Gray)
Room C (Yellow)
Room D (Blue)
Open the putty and
2
remove the gas pipe
thermistor.
4. Remove the
heat
exchanger thermistor
1
Remove the heat
exchanger thermistor.
Removal Procedure
Procedure
Outdoor Unit
Points
Meet the edge of the
thermistor and clip.
The number of ports is
different according to the
models.