Fault Reset Methods - YASKAWA CIMR-JA Series Installation & Start-Up Manual

Compact v/f control drive
Hide thumbs Also See for CIMR-JA Series:
Table of Contents

Advertisement

5.7 Diagnosing and Resetting Faults
u

Fault Reset Methods

After the Fault Occurs
Fix the cause of the fault,
restart the drive, and reset the
fault
Resetting via Fault Reset
Digital Input S4
If the above methods do not reset the fault, turn off the drive main power
supply. Reapply power after LED operator display is out.
142
YASKAWA ELECTRIC TOEP C710606 25B YASKAWA AC Drive J1000 Installation & Start-Up Manual
Procedure
Press
on the digital operator.
Close then open the fault signal digital
input via terminal S4. S4 is set fault
reset as default (H1-04 = 12)
Fault Reset Switch
S4 Fault Reset Digital Input
SC Digital Input Common
ON
2
OFF
1
STOP
Drive

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-jt seriesJ1000 series

Table of Contents