How To Inspect Shroud Blocks; Shroud Tip Rework; First Stage Shrouds - GE MS-6001B Maintenance Instructions Manual

Gas turbines with dln-1 combustion systems gas only
Hide thumbs Also See for MS-6001B:
Table of Contents

Advertisement

Hot Gas Path Inspection — Inspection Procedures

Shroud Tip Rework

Rework and metal removal is allowed in the cross-hatched areas. No rework is permitted which pene-
trates below the center section. See Figure HGP-I.15.
Operation 4 — How to Inspect Shroud Blocks
1. Visually check the shrouds segments and hook fits for deposits, corrosion, erosion (pitting), cracks
and nicks or dents. Record findings on Inspection Form PGS/GT-FF-6098, PGS/GT-FF-6101 and
PGS/GT-FF-6104.
2. Visually inspect the shroud seals for distortion, rubs, wear, and missing pieces. See Figure
HGP-I.16.
Note: The shrouds do not have to be disassembled from the turbine casing for
this inspection.

First Stage Shrouds

Turbine shroud block cracks are a result of low cycle thermal fatigue or thermal compressive over-
load. The cracks will propagate into the metal until the operating stress levels at the crack front are
sufficiently reduced. The cracks are generated normal to the gas path surface and are not smooth in
nature. Experience indicates that pieces of the shroud do not come out, and foreign object damage
is not anticipated.
If two or more cracks are diverging and it appears that a piece may come out, then the block should
be replaced. Also, if a crack goes greater than 80% through the metal thickness at any borescope hole,
the block should be replaced.
Corrosion of the first-stage shrouds is generally the result of contaminants in the air or fuel. Excessive
corrosion should be investigated; it may lead to loss of turbine stage performance.
Metal removal that leaves a smooth undulating surface or scalloped gas path surface is usually due
to abrasive materials in the cycle air or the fuel. Excessive erosion should be investigated.
Severe oxidation or ablation of the gas path surface may be caused by operation outside of specifica-
tion, including improper control system calibration and liquid carry-over in gas fuels. Severe oxida-
tion or ablation may be an indication of serious problems that could lead to turbine damage and should
be investigated. Metal loss of 1/8 inch or more in any case should be investigated.
Note: Contact GE Representative for disposition if blocks are out of limits.
HGP-I-16
CAUTION
Equal amounts of material should be removed from the
leading and trailing edges.
Inspection and Maintenance — GEK 107048