Inspection and Maintenance — GEK 107048
Figure HGP-D.12. First-Stage Nozzle Lifting Angles for Support Pad and or Support Pin Type Nozzle.
27
27
30
30
27
27
Retaining
Ring
Nozzle
(9 Each Half)
Support Pad
Retainer
Support Pad
Hot Gas Path Inspection — Disassembly Procedures
Lifting Angle
(Welded On Retaining Ring 27
From Vertical Centerline)
2 On Top Half
4 On Lower Half
Bolt (1.00–8)
Tapped In Lower Half
(2 Each Side)
Dowel Pin
(2 Each Side)
1.90 Max.
Retaining
Ring
Nozzle
(9 Each Half)
Tangential
Support Pin
HGP-D-21