Ricoh PE-P4 Field Service Manual page 138

Hide thumbs Also See for PE-P4:
Table of Contents

Advertisement

5. System Maintenance Reference
Registration Adjust
Size Adjust
Fax Maintenance
Modem Settings
136
Adjusts the ADF Scan main-scan registration.
ADF Main Reg.
[-1.0 to 1.5 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan sub-scan registration.
ADF Sub Reg.
[-1.0 to 1.5 / 0 (Default)/ 0.1 mm/step]
Adjusts the Flatbed Scan main-scan registration.
Flatbed Main Reg.
[-1.0 to 1.5 / 0 (Default)/ 0.1 mm/step]
Adjusts the Flatbed Scan sub-scan registration.
Flatbed Sub Reg.
[-1.0 to 1.5 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan main-scan magnification.
ADF Main Reg.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the ADF Scan sub-scan magnification.
ADF Sub Reg.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan main-scan magnification.
Flatbed Main Reg.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan sub-scan magnification.
Flatbed Sub Reg.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Sets the reception level.
RX Level
[-43 dBm (Default)/ -33 dBm/ -26 dBm
/ -16 dBm]
Sets the transmission level.
[0 dBm/ -1 dBm/ -2 dBm/ -3 dBm/ -4 dBm
TX Level
/ -5 dBm/ -6 dBm/ -7 dBm/ -8 dBm/ -9 dBm
/ -10 dBm/ -11 dBm/ -12 dBm/ -13 dBm
/ -14 dBm/ -15 dBm]
These selectors are used to improve the pass-band
characteristics of analogue signals on the telephone line.
Cable Equalizer
[0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]