Function Mode - Hitachi SJ700D-004L Instruction Manual

Sj700d-3 series
Hide thumbs Also See for SJ700D-004L:
Table of Contents

Advertisement

Chapter 8
Code
Function name
d022 Life-check monitoring
d023 Program counter
d024 Program number monitoring
d025 User monitor 0
d026 User monitor 1
d027 User monitor 2
d028 Pulse counter
d029 Position setting monitor
d030 Position feedback monitor
d031 Clock monitor
d060 Inverter mode monitor
d080 Trip Counter
d081 Trip monitoring 1
d082 Trip monitoring 2
d083 Trip monitoring 3
d084 Trip monitoring 4
d085 Trip monitoring 5
d086 Trip monitoring 6
d090 Programming error monitoring Warning code
d102 DC voltage monitoring
d103 BRD load factor monitoring
Electronic thermal overload
d104
monitoring
(Note) CT : Constant torque mode, VT : Variable torque mode, you can set CT or VT by b049.

8.3 Function Mode

Code
Function name
F001 Output frequency setting
F002 Acceleration (1) time setting
Acceleration (1) time setting,
F202
2nd motor
Acceleration (1) time setting,
F302
3rd motor
F003 Deceleration (1) time setting
Deceleration time setting,
F203
2nd motor
Deceleration time setting,
F303
3rd motor
F004 Keypad Run key routing
Monitored data or setting
ON
OFF
2
1
0 to 1024
0000 to 9999
-2147483647 to 2147483647 (upper 4 digits including "-")
0 to 2147483647 (upper 4 digits)
-1073741823 to 1073741823 (upper 4 digits including "-")
* In case you use WOP (option), this monitor is activated.
I-C(CT)/ I-v(VT)
0. to 9999., 1000 to 6553 (10000 to 65530) (times)
Factor,
frequency (Hz),
current (A),
voltage across P-N (V),
running time (hours),
power-on time (hours)
0.0 to 999.9 (V)
0.0 to 100.0 (%)
Monitored data or setting
0.0, "start frequency" to "maximum frequency" (or maximum
frequency, 2nd/3rd motors) (Hz)
0.0 to 100.0 (when PID function is enabled)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
00 (forward rotation), 01 (reverse rotation)
1:Capacitor on main circuit board
2:Cooling-fan speed drop
Default
FF
8-2
List of Data Settings
Change during
Default
RUN operation
FF
FEF
FUF b031≠10 b031=10
Change during
RUN operation
Memo
FEF FUF
b031≠10 b031=10
0.00
Allowed Allowed
30.00
Allowed Allowed 4-10
30.00
Allowed Allowed 4-10
30.00
Allowed Allowed 4-10
30.00
Allowed Allowed 4-10
30.00
Allowed Allowed 4-10
30.00
Allowed Allowed 4-10
00
Not
Not
Page
4-4
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-6
4-6
4-6
4-6
4-6
Page
4-7
4-7