Hitachi SJ700D-004L Instruction Manual page 192

Sj700d-3 series
Hide thumbs Also See for SJ700D-004L:
Table of Contents

Advertisement

Chapter 4
(v) 04 command: This command reads the status of the inverter.
- Transmission frame
Frame format
STX
Station No.
STX
Control code (Start of TeXt)
Station number of control-target
Station No.
inverter
Command
Command to be transmitted
BCC
Block check code
CR
Control code (Carriage Return)
- Response frame
Frame format
STX
Station No.
STX
Control code (Start of TeXt)
Station number of control-target
Station No.
inverter
Data
Data
BCC
Block check code
CR
Control code (Carriage Return)
Note 10: The data indicating the status of the inverter consists of the following three status elements (A, B, and C):
Data
Status A
Status B
Inverter status A
Code
Status
00
Initial status
01
02
Stopping
03
Running
04
Free-run stop (FRS) in progress
05
Jogging (JG) in progress
06
DC braking (DB) in progress
07
Retry in progress
08
Tripping
09
Undervoltage (UV) status
Command
BCC
Description
Data
BCC
Description
Status C
00 (reserved)
Inverter status B
Code
00
01
02
Explanation of Functions
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32
2 bytes
04
XOR of the items from "Station No." to "Data." See
2 bytes
Item (3) of this section.
1 byte
CR (0x0D)
CR
Data size
1 byte
STX (0x02)
2 bytes
01 to 32
8 bytes
See Note 8.
XOR of the items from "Station No." to "Data." See
2 bytes
Item (3) of this section.
1 byte
CR (0x0D)
Status
Stopping
Running
Tripping
4-121
Setting
Setting
Inverter status C
Code
Status
00
---
01
Stopping
02
Decelerating
03
Constant-speed operation
04
Accelerating
05
Forward operation
06
Reverse operation
07
Switching forward operation
to reverse operation
08
Switching reverse operation
to forward operation
09
Starting forward operation
10
Starting reverse operation

Advertisement