Code
Function name
b034
Run/power-on warning time
b035
Rotational direction restriction
b036
Reduced voltage start selection
b037
Function code display restriction
b038
Initial-screen selection
Automatic user-parameter setting
b039
function enable
b040
Torque limit selection
Torque limit (1) (forward-driving in
b041
4-quadrant mode)
Torque limit (2)
b042
(reverse-regenerating in
4-quadrant mode)
Torque limit (3) (reverse-driving in
b043
4-quadrant mode)
Torque limit (4)
b044
(forward-regenerating in
4-quadrant mode)
b045
Torque limit LADSTOP enable
b046
Reverse Run protection enable
b049
Dual rating selection
Controller deceleration and stop
b050
on power loss
DC bus voltage trigger level during
b051
power loss
Over-voltage threshold during
b052
power loss
Deceleration time setting during
b053
power loss
Initial output frequency decrease
b054
during power loss
Proportional gain setting for
b055
nonstop operation at power loss
Integral time setting for nonstop
b056
operation at power loss
Maximum-limit level of window
b060
comparators O
Minimum-limit level of window
b061
comparators O
Hysteresis width of window
b062
comparators O
Maximum-limit level of window
b063
comparators OI
Minimum-limit level of window
b064
comparators OI
Hysteresis width of window
b065
comparators OI
Maximum-limit level of window
b066
comparators OI
Minimum-limit level of window
b067
comparators O/OI/O2
Hysteresis width of window
b068
comparators O/OI/O2
b070
Operation level at O disconnection
b071
Operation level at OI disconnection
Operation level at O2
b072
disconnection
(Note) <>indicate the setting range of 75 to 150kW
(Note) CT : Constant torque mode, VT : variable torque mode, you can set CT or VT by b049.
*) In case of connecting OPE-S to the inverter, '201' setting is same as '00' setting. Refer to the SJ700D-3 instruction manual.
Monitored data or setting
0. to 9999. (0 to 99990), 1000 to 6553 (100000 to 655300) (hr)
00 (enabling both forward and reverse rotations),
01 (enabling only forward rotation), 02 (enabling only reverse rotation)
0 (minimum reduced voltage start time) to 255 (maximum reduced voltage
start time)
00 (full display), 01 (function-specific display), 02 (user setting),
03 (data comparison display), 04 (basic display)
00 (screen displayed when the STR key was pressed last),
001~060 (d001~d060), 201 (F001) 202 *)
00 (disabling), 01 (enabling)
00 (quadrant-specific setting), 01 (switching by terminal), 02 (analog input),
03 (option 1), 04 (option 2)
0. to 200. (%), no (disabling torque limitation)
<0. to 150. (%), no (disabling torque limitation)> (In case of CT)
0. to 150. (%), no (disabling torque limitation)(In case of VT)
00 (disabling), 01 (enabling)
00 (disabling), 01 (enabling)
00 (CT : Constant torque)
01 (VT : Variable torque)
00 (disabling), 01 (nonstop deceleration to stop),
02 (DC voltage constant control, with resume), 03 ( without resume)
0.0 to 999.9, 1000. (V)
0.0 to 999.9, 1000. (V)
0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)
0.00 to 10.00 (Hz)
0.00 to 2.55
0.000 to 9.999 /10.00 to 65.53 (s)
0. to 100.
(lower limit : b061 + b062 x 2) (%)
0. to 100.
(upper limit : b060 - b062 x 2) (%)
0. to 10.
(upper limit : b060 - b061 / 2) (%)
0. to 100.
(lower limit : b064 + b065 x 2) (%)
0. to 100.
(upper limit : b063 - b065 x 2) (%)
0. to 10.
(upper limit : b063 - b064 / 2) (%)
-100. to 100.
(lower limit : b067 + b068 x 2) (%)
-100. to 100.
(upper limit : b066 - b068 x 2) (%)
0. to 10.
(upper limit : b066 - b067 / 2) (%)
0. to 100. (%) or "no" (ignore)
0. to 100. (%) or "no" (ignore)
-100. to 100. (%) or "no" (ignore)
8-7
List of Data Settings
Change during
Default
RUN operation
Memo
FF FEF FUF
b031≠10 b031=10
0.
Not
Allowed 4-64
00
Not
6
Not
Allowed 4-42
00
Not
Allowed 4-76
001
Not
Allowed 4-78
00
Not
Allowed 4-79
00
Not
Allowed
150.(CT)
Not
Allowed
120.(VT)
150.(CT)
Not
Allowed
120.(VT)
150.(CT)
Not
Allowed
120.(VT)
150.(CT)
Not
Allowed
120.(VT)
00
Not
Allowed 4-94
00
Not
Allowed 4-93
00
Not
00
Not
220.0/440.0
Not
360.0/720.0
Not
1.00
Not
0.00
Not
0.20
Allowed Allowed
0.100
Allowed Allowed
100
Allowed Allowed
0.
Allowed Allowed
0.
Allowed Allowed
100.
Allowed Allowed
0.
Allowed Allowed
0.
Allowed Allowed
100.
Allowed Allowed
-100.
Allowed Allowed
0.
Allowed Allowed
no
Not
Allowed
no
Not
Allowed
no
Not
Allowed
Page
Not
4-7
4-92
Not
3-22
Not
Not
Not
Not
4-83
Not
4-71