Mitsubishi MELSEC-Q QD77MS User Manual page 897

Simple motion module
Table of Contents

Advertisement

Classification
Warning
Warning name
of warnings
code
Outside mark detection
132
data axis No. setting
range
Common
warnings
Outside mark detection
133
data buffer memory No.
setting range
Speed change during
300
deceleration
JOG operation
warnings
301
JOG speed limit value
Manual pulse
Outside manual pulse
generator
401
generator input
operation
magnification range
warnings
Warning
When the mark detection data type setting
is not "Optional 2 word buffer memory",
the mark detection data type setting is
outside the range.
When the mark detection data type setting
is "Optional 2 word buffer memory", the
mark detection data buffer memory No. is
outside the range or odd number.
The speed change request is issued
during deceleration stop with JOG start
signal OFF.
(Note-1)
• The JOG speed
is exceeded the
speed limit value at start.
(Note-1)
• The new speed value
exceeds
the JOG speed limit value when the
speed is changed during operation.
(Note-1): This speed is a value in which
override value is considered
when override function is used.
(" Cd.13 Positioning operation
speed override" is set other then
100[%].)
The manual pulse generator 1 pulse input
magnification is set to 0, 10001 or more,
or negative value.
16 - 66
Chapter 16 Troubleshooting
Operation status at warning occurrence
All mark detections are not operated.
The speed change is not carried out.
• When the speed exceeds the JOG speed
limit, the JOG operation is carried out with
the JOG speed limit value.
• While the speed is limited by the JOG
speed limit value, the "
In speed limit
Md.39
" is turned ON.
flag
• When input magnification is set at 10001
or more, or negative value:
Re-set to 10000.
• When input magnification is set at 0: Re-
set to 1.

Advertisement

Table of Contents
loading

Table of Contents