Engine diagnostics flow
Power
on
Engine ROM
checksum OK?
Yes
Fuser heater
temp. normal?
Yes
Fuser heater
normal?
Yes
Is fuser new?
Yes
Fuser life fuse
blown?
Yes
A
No
D0: Firmware program error
No
A2: Fuser overheating
No
A3: Fuser heater disconnection
No
E8: Fuser unit life fuse error
5A2