The V680 Series must be inspected on a daily or regular basis so that the functions of the V680 Series can be used
in good condition.
The V680 Series consists of semiconductors that last almost indefinitely. The following malfunctions may, however,
result due to the operating environment and conditions.
(1) Element deterioration due to overvoltage or overcurrent.
(2) Element deterioration due to continuous stress caused by high ambient temperature.
(3) Connector contact faults or insulation deterioration due to humidity and dust.
(4) Connector contact faults or element corrosion due to corrosive gas.
Inspection Items
Item
Supply voltage fluctuation
Ambient envi-
Temperature
ronment
Humidity
Vibration and
shock
Dust
Corrosive gas
Panel condi-
Ventilation
tion
Damage to
packing for
any enclosed
construction
I/O power
Voltage fluctu-
supply
ation
Ripple
Mounting condition
Heat-resistive RFID System
80
User's Manual
Detail
Check that the supply voltage fluctuation at
the power supply terminal block is within the
permissible range.
Check that there are no frequent instanta-
neous power failures or radical voltage fluc-
tuations.
Within the specified range
Influence of vibration or impact of machines
Check that the system is free of accumu-
lated dust and foreign particles.
Check that no metal part of the system is
discolored or corroded.
Check that the system is ventilated properly
with natural ventilation, forced ventilation, or
cooling air.
Check that the panel packing is properly
attached with no damage.
Check on the I/O terminal block that the volt-
age fluctuation and ripple are within the per-
missible ranges.
Check that each device is securely
mounted.
Check that each connector is fully inserted.
Check that no wire is broken or nearly bro-
ken.
Check that no screw of the terminal block is
loose.
Check that the distance between the Tag
and Antenna is within the specified range.
Check that the GR terminal is grounded.
Criteria
Within supply voltage specified range
Within permissible voltage fluctuation
range
Within the specified range
Neither is permitted.
The interior temperature must be within
a range between − 10 ° C and 55 ° C with
proper ventilation.
The packing has no damage.
Within the specified range
No loose screws
Each connector is locked or securely
tightened with screws.
No wire that is broken or nearly broken. ---
No loose screws
Within the specified range
The terminal must be grounded to a
resistance of 100 Ω or less.
Required
equipment
Multimeter
Power supply
analyzer
Maximum and
minimum ther-
mometer
Hygrometer
---