Controller Control Commands

CONTROLLER CONTROL (CC)
This command reads the status of the input terminals.
Command
Controller No.
Command code
×
×
@
3
Name
Processing code
Response
Controller No.
Command code
×
×
@
3
Name
End code
Input status
Output status
• Example
Displaying the present input status for Controller No. 2.
Command
Controller No.
Command code
0
2
@
3
Response
Controller No.
Command code
@
0
2
3
Processing code
C
C
0
0
0
2
4
Always 0000
End code
Input status
×
C
C
0
0
2
2
2
Indicates the execution result for the command.
The end code 00 indicates normal completion.
Indicates the present input status
Leftmost digit: 1 (ON), 0 (OFF)
Rightmost digit: 1 (ON), 0 (OFF)
Always 00
Processing code
0
C
C
0
0
2
4
End code
Input status
7
5
C
C
1
2
2
2
Reading from/Writing to Tags
FCS
Terminator
×
×
*
0
CR
2
2
Details
Output status
FCS
×
×
×
0
0
2
2
Details
FCS
Terminator
*
0
4
2
CR
2
2
Output status
FCS
1
0
0
4
0
2
2
Heat-resistive RFID System
Section 4
Terminator
*
CR
2
Terminator
*
CR