Communications Test - Omron V680-CA1D User Manual

V680 series heat-resistive rfid system
Table of Contents

Advertisement

Section 3
Before Communications

Communications Test

Check Items
Check the following items before the trial operation of the whole system.
No.
1
Power supply and
I/O line connections
2
DIP switch settings
3
Antenna connection
4
Host device connection
5
Antenna and Tag connection
Procedure for Trial Operation
Turn power ON
Online test with
the host device
Trial operation of
the system
Completion
Heat-resistive RFID System
42
User's Manual
Items
• Are the power supply and I/O lines properly wired?
• Are all the terminal screws tightened securely?
• Is the node number set correctly?
• Are the communications specifications set correctly?
Is the Antenna connected properly?
Is the RS-232C/RS-485 connector connected properly?
Are the Antenna and Tag located properly?
• Check that the supply voltage and the connection of power supply
terminals are correct.
• Check that the RUN indicator of the Controller and the POWER
indicator of the Antenna are ON.
Check the communications between the host device and Controller
with test commands.
Check the operation of the whole system with actual commands
executed.