Omron V680-CA1D User Manual page 62

V680 series heat-resistive rfid system
Table of Contents

Advertisement

Section 4
Reading from/Writing to Tags
FCS Calculation Example
FCS (Frame Check Sequence) refers to 8-bit data with an exclusive OR (XOR) executed from the start
of the frame (@ symbol) until the final character, converted into 2-bit ASCII.
• Reading 5 Bytes from Address 0010H
Controller No.
@
0
Read data
Heat-resistive RFID System
60
User's Manual
Command code
2
R
D
H
1
FCS calculation range
@
0
2
R
Converting to
D
ASCII
H
1
0
0
1
0
0
5
Data
0
0
1
0
0
ASCII
Hexadecimal
40
30
32
52
Converting to
44
hexadecimal
48
31
30
30
31
30
30
35
0010
FCS
Terminator
*
5
2
8
0100
0000
XOR
0011
0000
XOR
0011
0010
XOR
0101
0010
XOR
0100
0100
XOR
0100
1000
XOR
0011
0001
XOR
0011
0000
XOR
0011
0000
XOR
0011
0001
XOR
0011
0000
XOR
0011
0000
XOR
0011
0101
Exclusive OR (XOR)
1000
Converting to
ASCII
FCS data: 28
CR

Advertisement